Vulcan MG12 ML-52549 - Manual

Vulcan MG12 ML-52549

Vulcan MG12 ML-52549 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
Page: / 20

Table of Contents:

  • Page 3 – TABLE OF CONTENTS; SERVICE
  • Page 4 – MODEL SUFFIX DESIGNATIONS; T - Thermostatic Control
  • Page 5 – SERVICE NOTATIONS; service representatives.; CHECKS AND ADJUSTMENTS
  • Page 8 – OFF when gas begins to flow.
  • Page 10 – clockwise to decrease flame, until the flame appears to be
  • Page 11 – Temperature Calibration; Light the main burner by turning the thermostat to 500
  • Page 12 – REGULATOR CHECK; Gas supply pressure must not be greater than
  • Page 14 – REGULATOR ADJUSTMENT
  • Page 15 – Column for propane gas.; REGULATOR INSTALLATION; Install new regulator as indicated above.
  • Page 16 – Disconnect range gas supply and allow range to cool.
  • Page 18 – TOP SECTION PILOT CHECK; Disconnect range from main gas supply and allow range to cool.; PILOT ADJUSTMENT VALVE REPLACEMENT; Disconnect range from main gas supply and allow to cool.
  • Page 19 – Disconnect main gas supply and allow to cool.; SERVICE AND PARTS INFORMATION
Loading the manual

SERVICE MANUAL

V U L C A N - H A R T C O M P A N Y , P . O . B O X 6 9 6 , L O U I S V I L L E , K Y 4 0 2 0 1 - 0 6 9 6 , T E L . ( 5 0 2 ) 7 7 8 - 2 7 9 1

FORM 30837 Rev. A (7-95)

MG12

GAS RESTAURANT RANGE

MG 12, 24, 36, 48 AND 60

MODEL

MG12

ML-52549

MG24

ML-52514

MG36

ML-52522

MG48

ML-52523

MG60

ML-52524

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 3 - TABLE OF CONTENTS; SERVICE

– 3 – TABLE OF CONTENTS MG SERIES GAS RESTAURANT MODULAR RANGE MODELS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 SERVICE NOTATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 SERV...

Page 4 - MODEL SUFFIX DESIGNATIONS; T - Thermostatic Control

– 4 – MG SERIES GAS RESTAURANT MODULAR RANGE MODELS MODEL SUFFIX DESIGNATIONS S - 12" Griddle Z - 48" Griddle F - 24" Griddle T - Thermostatic Control X - 36" Griddle PL-40044-1

Page 5 - SERVICE NOTATIONS; service representatives.; CHECKS AND ADJUSTMENTS

– 5 – SERVICE NOTATIONS 1. The procedures outlined in this manual are to be performed only by Vulcan-Hart authorized service representatives. 2. An authorized Vulcan-Hart service representative is one who is familiar with Vulcan equipment and who has been endorsed by Vulcan-Hart Company to service t...

Other Vulcan Models

All Vulcan Other