Vulcan 924RE ML-135221-00G24, 936RE ML-135222-00G36, 948RE ML-135223-00G48, 960RE ML-135224-00G60, 972RE ML-135225-00G72 - Manual
Vulcan 924RE ML-135221-00G24, 936RE ML-135222-00G36, 948RE ML-135223-00G48, 960RE ML-135224-00G60, 972RE ML-135225-00G72 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – TABLE OF CONTENTS
- Page 3 – No lubrication is required on this equipment.; Electrical Data; Model; Gas Data; Manometer; GENERAL
- Page 4 – REMOVAL AND REPLACEMENT OF PARTS; COMPONENT LOCATION; Figure A
- Page 5 – CONTROL PANEL; Figure B; COVERS AND PANELS; Bullnose Weld Assembly
- Page 6 – Figure E; INDICATOR LIGHT
- Page 7 – FLAME SWITCH; Figure F; IGNITOR MODULE; Figure G
- Page 8 – GAS BURNER; Figure H; PILOT SOLENOID; Figure I
- Page 9 – PILOT; Figure J; DUAL SOLENOID; Figure K
- Page 10 – THERMOSTAT CALIBRATION; Figure L; MAIN BURNER ADJUSTMENT; SERVICE PROCEDURES AND ADJUSTMENTS
- Page 11 – GAS PRESSURE MEASUREMENT; Figure M
- Page 12 – COMPONENT DESCRIPTION; Ignition Control Module; SEQUENCE OF OPERATION; ELECTRICAL OPERATION
- Page 13 – SCHEMATIC DIAGRAMS; Schematic Drawing for 24” Griddle; USE SUPPLY WIRES SUITABLE FOR 200
- Page 14 – Schematic Drawing for 36” Griddle
- Page 15 – Schematic Drawing for 48” Griddle
- Page 16 – Schematic Drawing for 60” Griddle
- Page 17 – Schematic Drawing for 72” Griddle
- Page 18 – TROUBLESHOOTING GUIDE; SYMPTOM
- Page 19 – REMEDY
SERVICE MANUAL
For additional information on Vulcan-Hart or to locate an authorized parts
and service provider in your area, visit our website at www.vulcanhart.com
F35628 (10-04)
- NOTICE -
This manual is prepared for the use of trained Vulcan Service
Technicians and should not be used by those not properly qualified.
If you have attended a Vulcan Service School for this product, you
may be qualified to perform all the procedures described in this
manual.
This manual is not intended to be all encompassing. If you have not
attended a Vulcan Service School for this product, you should
read, in it's entirety, the repair procedure you wish to perform to
determine if you have the necessary tools, instruments and skills
required to perform the procedure. Procedures for which you do
not have the necessary tools, instruments and skills should be
performed by a trained Vulcan Service Technician.
Reproduction or other use of this Manual, without the express
written consent of Vulcan, is prohibited.
900RE SERIES
HEAVY DUTY
GAS GRIDDLES
MODELS
924RE
ML-135221-00G24
936RE
ML-135222-00G36
948RE
ML-135223-00G48
960RE
ML-135224-00G60
972RE
ML-135225-00G72
VULCAN-HART
DIVISION OF ITW FOOD EQUIPMENT GROUP, LLC
WWW.VULCANHART.COM
P.O. BOX 696, LOUISVILLE, KY 40201-0696
TEL. (502) 778-2791
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
— 2 — F35628 (10-04) TABLE OF CONTENTS GENERAL ........................................................................................................................................ 3 Introduction ........................................................................................................
— 3 — F35628 (10-04) INTRODUCTION Procedures in this manual will apply to allm o d e l s u n l e s s s p e c i f i e d . P i c t u r e s a n dillustrations can be of any model unless thepicture or illustration needs to be modelspecific. All models are equipped with 30,000BTU/HR burners as standard e...
— 4 — F35628 (10-04) REMOVAL AND REPLACEMENT OF PARTS COMPONENT LOCATION Figure A Bullnose Deflector Plate Heat Shield Control Plate Control Panel Grease Drawer Griddle Flame Switch Ignitor Module Dual Solenoid PilotSolenoid Dual Solenoid Ignitor Module Panel Connector Flame Switch Back Panel