Page 2 - IMPORTANT FOR YOUR SAFETY
GRA, GRAF, & VFRY GAS FRYERS & VFRY SERIES HD FRYERS VULCAN-HART F-32934 Rev. J (August 2012) -2- IMPORTANT FOR YOUR SAFETY THIS MANUAL HAS BEEN PREPARED FOR PERSONNEL QUALIFIED TO INSTALL GAS EQUIPMENT, WHO SHOULD PERFORM THE INITIAL FIELD START-UP AND ADJUSTMENTS OF THE EQUIPMENT COVERED B...
Page 3 - TABLE OF CONTENTS
GRA, GRAF, & VFRY GAS FRYERS & VFRY SERIES HD FRYERS VULCAN-HART F-32934 Rev. J (August 2012) -3- TABLE OF CONTENTS IMPORTANT FOR YOUR SAFETY………………………………………. 2 INTRODUCTION…………………………………………………………… 4 GENERAL…………………………………………………………… 4 ORDERING PARTS………………………………………………… 4 FRYER CAPACITIES………………………...
Page 4 - INTRODUCTION; GENERAL; ORDERING PARTS; FRYER CAPACITY; UNPACKING
GRA, GRAF, & VFRY GAS FRYERS & VFRY SERIES HD FRYERS VULCAN-HART F-32934 Rev. J (August 2012) -4- INTRODUCTION GENERAL Vulcan Fryers are produced with quality workmanship and material. Proper installation, usage and maintenance will result in years of satisfactory performance. Before install...
Page 5 - PLUS®; INSTALLATION
GRA, GRAF, & VFRY GAS FRYERS & VFRY SERIES HD FRYERS VULCAN-HART F-32934 Rev. J (August 2012) -5- Check that the following have been included: Crumb Rack(s) Basket Hanger(s) Tank Brush Adjustable Casters (4) two locking, two non-locking for freestanding fryers. Fryer Batteries with t...
Page 6 - CODES AND STANDARDS; In the United States:
GRA, GRAF, & VFRY GAS FRYERS & VFRY SERIES HD FRYERS VULCAN-HART F-32934 Rev. J (August 2012) -6- Clearances: Minimum clearance from combustible construction: 6” (15 cm) from the sides of the fryer 6” (15 cm) from the back of the fryer The fryer may be installed on combustible floors. Mi...
Page 7 - Local; ASSEMBLY; Make the flue connection as follows:
GRA, GRAF, & VFRY GAS FRYERS & VFRY SERIES HD FRYERS VULCAN-HART F-32934 Rev. J (August 2012) -7- National Electrical Code, ANSI/NFPA-70 (latest edition). Copies may be obtained from The National Fire Protection Association, Batterymarch Park, Quincy, MA. 02169-7471. In the commonwealth ...
Page 8 - GAS CONNECTION; All gas supply connections and any pipe joint compound must be; Prior to lighting, check all joints in the gas supply line for leaks.
GRA, GRAF, & VFRY GAS FRYERS & VFRY SERIES HD FRYERS VULCAN-HART F-32934 Rev. J (August 2012) -8- GAS CONNECTION All gas supply connections and any pipe joint compound must be resistant to the action of propane gases. The gas inlet is located on the lower rear of the fryer. Codes require tha...
Page 9 - The fryer must be installed with the casters provided.; ELECTRICAL CONNECTION; Electrical Grounding Instructions:
GRA, GRAF, & VFRY GAS FRYERS & VFRY SERIES HD FRYERS VULCAN-HART F-32934 Rev. J (August 2012) -9- When installing a quick disconnect you must also install a means for limiting the movement of the fryer. This device will prevent the gas line or quick disconnect from being strained. The rest...
Page 10 - LEVELING THE FRYER; Hot oil and parts can cause burns. Use care when operating,; OVER-TEMPERATURE SHUTDOWN; Do not use chlorine or sulfate/sulfide cleaners.
GRA, GRAF, & VFRY GAS FRYERS & VFRY SERIES HD FRYERS VULCAN-HART F-32934 Rev. J (August 2012) -10- the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.2, as applicable. Electrical diagram located on inside of door. LEVELING THE FRYER Check the level of the fr...
Page 11 - FILLING TANK WITH SHORTENING
GRA, GRAF, & VFRY GAS FRYERS & VFRY SERIES HD FRYERS VULCAN-HART F-32934 Rev. J (August 2012) -11- Rinse fryer and accessories thoroughly and drain the fryer. Wipe tank completely dry with a soft, clean cloth. FILLING TANK WITH SHORTENING Close the drain valve. Fill the fryer tank wi...
Page 12 - Fry Basket Capacity:; EXTENDING SHORTENING LIFE
GRA, GRAF, & VFRY GAS FRYERS & VFRY SERIES HD FRYERS VULCAN-HART F-32934 Rev. J (August 2012) -12- Fry Basket Guidelines Do not overfill baskets. (See fry basket capacity below) Carefully lower basket into oil. When frying doughnuts and fritters, turn product only once during frying. W...
Page 13 - TURNING ON THE FRYER; Set temperature by turning the knob to the desired temperature.; TURNING OFF THE FRYER
GRA, GRAF, & VFRY GAS FRYERS & VFRY SERIES HD FRYERS VULCAN-HART F-32934 Rev. J (August 2012) -13- Solid State Knob Control Indicator Lights (On/Start/Heating) Temperature Knob Control Melt Switch Power Switch Filter Switch (For those models with KleenScreen PLUS® Filter Systems) Start Butto...
Page 15 - EXTENDED SHUTDOWN; Hot oil and hot parts can cause burns. Use care when operating,
GRA, GRAF, & VFRY GAS FRYERS & VFRY SERIES HD FRYERS VULCAN-HART F-32934 Rev. J (August 2012) -15- EXTENDED SHUTDOWN 1. Open the door to the fryer. Press the power switch to the OFF position. 2. Thoroughly drain the fryer. Refer to DRAINING THE FRYER. 3. Clean the fryer according to CLEANING...
Page 16 - DRAINING THE TANK; Then clean-out as described under CLEANING.; BOIL OUT PROCEDURE; Drain the tank as described under FILTERING THE OIL.
GRA, GRAF, & VFRY GAS FRYERS & VFRY SERIES HD FRYERS VULCAN-HART F-32934 Rev. J (August 2012) -16- DRAINING THE TANK 1. Open the door to the fryer. The power must remain ON for the fryer to filter correctly. 2. Insert the drain extension into the drain valve. Tighten only hand tight. 3. Dire...
Page 17 - CLEANING
GRA, GRAF, & VFRY GAS FRYERS & VFRY SERIES HD FRYERS VULCAN-HART F-32934 Rev. J (August 2012) -17- 10. Close the drain valve and add shortening. Follow the FILLING TANK WITH SHORTENING procedure in this manual. The fryer is now ready for use. Press the start button to begin heating the short...
Page 18 - KleenScreen Plus® Filtration System; Installation and Operational Manual for “AF” Models
GRA, GRAF, & VFRY GAS FRYERS & VFRY SERIES HD FRYERS VULCAN-HART F-32934 Rev. J (August 2012) -18- KleenScreen Plus® Filtration System Installation and Operational Manual for “AF” Models 2GR45AF Shown GAS KleenScreen PLUS® Models: 1GR45AF ML-136798 1GR65AF ML-136795 1GR85AF ML-136796 2GR45AF...
Page 19 - Filtering Instructions for KleenScreen PLUS® Fryers; General; The KleenScreen; Assembly; Filter Insert
GRA, GRAF, & VFRY GAS FRYERS & VFRY SERIES HD FRYERS VULCAN-HART F-32934 Rev. J (August 2012) -19- Filtering Instructions for KleenScreen PLUS® Fryers General The KleenScreen PLUS ® filtration system filters the oil as it is pumped back into its’ respective tank(s). Only one tank can be drai...
Page 20 - Fully assembled filter screen assembly:; Same Suction Tube
GRA, GRAF, & VFRY GAS FRYERS & VFRY SERIES HD FRYERS VULCAN-HART F-32934 Rev. J (August 2012) -20- Fully assembled filter screen assembly: Fig. 2 Secure Tube with Suction Tube Clip Filter Screen Lays Flat On Bottom of Filter Pan Fig. 3 Micro-Filtration Fabric Envelope Assembly: Same Suction ...
Page 22 - Operation; will void your fryer warranty.
GRA, GRAF, & VFRY GAS FRYERS & VFRY SERIES HD FRYERS VULCAN-HART F-32934 Rev. J (August 2012) -22- Operation Hot oil and parts can cause burns. Use care when operating, cleaning and servicing the fryer. Spilling hot frying compound can cause severe burns. Do not move fryer without draining a...
Page 24 - REMOVING EXCESS DEBRIS FROM THE SCREEN FILTER:; insert by unlatching the latch. Clean all parts thoroughly.
GRA, GRAF, & VFRY GAS FRYERS & VFRY SERIES HD FRYERS VULCAN-HART F-32934 Rev. J (August 2012) -24- FILTERING TIP: Open the filtering drawer approximately 1” to allow any oil in the return line to run back into the filter pan. This will take about 30 seconds to complete. Then open the drawer ...
Page 25 - Do not allow water to run through the motor / pump.; Boil Out By-PassTM Extension Tube
GRA, GRAF, & VFRY GAS FRYERS & VFRY SERIES HD FRYERS VULCAN-HART F-32934 Rev. J (August 2012) -25- BOIL OUT PROCEDURE: Use the Boil Out By-Pass™ drain extension allowing the boil out solution to exit the fry tank without using the filtering system. Do not allow water to run through the motor...
Page 26 - MAINTENANCE; FLUE VENT INSPECTION; Probable
GRA, GRAF, & VFRY GAS FRYERS & VFRY SERIES HD FRYERS VULCAN-HART F-32934 Rev. J (August 2012) -26- MAINTENANCE Hot oil and hot parts can cause burns. Use care when operating, cleaning, and servicing the fryer. Spilling hot fryer compound can cause severe burns. Do not move fryer without drai...