Vermont Casting 1637 - Manual

Vermont Casting 1637

Vermont Casting 1637 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
Page: / 28

Table of Contents:

  • Page 2 – Vermont Castings Seville; Introduction; Save These Instructions For Future Reference.; Table of Contents; #1889 Bottom Heat Shield Kit
  • Page 3 – Specifications; This value can vary depending on how the stove is; Drawings not to scale.
  • Page 4 – Chimneys; Installation; Masonry Chimneys
  • Page 5 – • Unused openings in an existing masonry chimney; Prefabricated Chimneys; High Temperature (650; Chimney Size; elbows. Slope horizontal
  • Page 7 – Connection Above the Fireplace; Double-check connector clearance to the ceiling.; Alternate methods approved by the NFPA:
  • Page 9 – Floor Protection; Floor Protection Requirements
  • Page 10 – Wall Shields
  • Page 12 – Seville 1635 Clearance Chart; STOVE CLEARANCE
  • Page 13 – Alcove Installations
  • Page 14 – Unpack the Stove; Assembly
  • Page 15 – Position the Fan body within the Rear Shroud as
  • Page 16 – Attach the Chimney Connector
  • Page 17 – multi-ported tubes located at the top of the firebox.; Burn Only High-Quality Wood; Operation
  • Page 18 – SEVILLE CONTROL SETTINGS; Burn Rate Primary Air Control Shutter Position; Starting and Maintaining a Fire; MEDIUM
  • Page 19 – Step 2. Place several sheets of crumpled newspaper; NOTE: Some chimneys need to be “primed,” or; Step 4. After the stove has been broken-in using
  • Page 20 – Refuel While the Embers Are Still Hot; Step 2. Open the door and check the ash level in the; Ash Disposal
  • Page 21 – Care of the Cast Iron Surface; • Be sure the glass is completely cool.; Glass Replacement; Inspect the Gasket. If the window gasket is in good; Gasket Replacement; Gasket Size; Maintenance
  • Page 22 – Adjust the Door; The Chimney System; Creosote; • Close the thermostat lever.
  • Page 23 – Annual Maintenance; Draft Management; Masonry Chimney
  • Page 25 – F. Creosote is volatile and; Backpuffing
  • Page 26 – Seville Woodburning Stove
  • Page 27 – Use only Vermont Castings Glass Panel part
  • Page 28 – HOW TO OBTAIN SERVICE; Warranty; LIMITED 3 YEAR WARRANTY; LIMITED 1 YEAR WARRANTY; EXCLUSIONS & LIMITATIONS; Vermont Castings, Majestic Products
Loading the manual

Homeowner’s
Installation and
Operating
Manual

For use in the
United States and Canada

SAFETY NOTICE: IF THIS APPLIANCE IS NOT PROPERLY INSTALLED,
OPERATED AND MAINTAINED, A HOUSE FIRE MAY RESULT.
TO REDUCE THE RISK OF FIRE, FOLLOW THE INSTALLATION INSTRUCTIONS.
FAILURE TO FOLLOW INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE,
BODILY INJURY OR EVEN DEATH. CONTACT LOCAL BUILDING OFFICIALS
ABOUT RESTRICTIONS AND INSTALLATION INSPECTION REQUIREMENTS IN
YOUR AREA.

Do Not Discard This Manual: Retain for Future Use

30001490 10/03 Rev. 3

The Seville

Woodburning Stove

Models 1635, 1636, 1637, 1638

1490

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Vermont Castings Seville; Introduction; Save These Instructions For Future Reference.; Table of Contents; #1889 Bottom Heat Shield Kit

2 Vermont Castings Seville 30001490 Introduction Thank you for choosing a Vermont Castings Seville to meet your heating needs.We're confident you will find the Seville to be an effective wood-burning heater incorporatingmodern, non-catalytic combustion technology with the classic aesthetic appeal of...

Page 3 - Specifications; This value can vary depending on how the stove is; Drawings not to scale.

3 Vermont Castings Seville 30001490 Specifications Seville, Model 1635 Maximum heat output ......................... 30,000 Btu’s/hr. 1 Area heated ...................................... Up to 1320 sq. ft. 2 Fuel size/type ...................................... 18” (46 cm) logs Loading ................

Page 4 - Chimneys; Installation; Masonry Chimneys

4 Vermont Castings Seville 30001490 Chimneys Your stove must be connected either to a soundmasonry chimney that meets local codes, to a relinedmasonry chimney that meets local codes, or to anapproved prefabricated metal chimney. Whichever ofthose types you use, the chimney and chimney con-nector mus...

Other Vermont Casting Models

All Vermont Casting Other