Tripp Lite SU3000RTXL3U - Manual

Tripp Lite SU3000RTXL3U

Tripp Lite SU3000RTXL3U – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
Page: / 6

Table of Contents:

  • Page 2 – SYSTEM OVERVIEW
  • Page 3 – Via 40A input breaker; INPUT; less than 6 hours to 90%; VOLTAGE REGULATION
  • Page 4 – Yes; PHYSICAL; Steel; Cooling method; Yes, includes PowerAlert software CD-ROM and complete cabling; SNMP compatibility
  • Page 5 – Related Items
  • Page 6 – DCATV; Tower Stands; Tower Stand - Expandable Tower Base Stand UPS Accessory
Loading the manual

Tripp Lite

1111 West 35th Street

Chicago, IL 60609 USA

Telephone: +(773) 869 1234

E-mail:

[email protected]

Model #: SU3000RTXL3U

SmartOnline Expandable 3U Rack / Tower UPS System - On-line, double-conversion, sine wave UPS with PDU
switching, current monitoring and fault tolerant auto-bypass

Highlights

3000VA / 2400W on-line, double-conversion, extended-run 3U rack / tower

UPS

Zero transfer time, on-line, double-conversion and economy-mode operation

supported

Maintains sine-wave 110/120V +/-2% output during overvoltages to 138 and

brownouts as low as 65V (50/60Hz auto-sensing)

Simultaneous use communications via HID compliant USB port, serial port,

SNMP/Web card slot and EPO interface

Fault tolerant auto-bypass mode, current monitoring and switched PDU control

via 2 switchable output load banks

Input: NEMA L5-30P (120V) / Output: 4 NEMA5-15R, 4 NEMA5-15/20R & 1

NEMA L5-30R

2 year product warranty / $250,000 Ultimate Lifetime Insurance (USA &

Canada only)

Estimated Retail Pricing: $1,400.00

Description

3000VA on-line, double-conversion UPS system for critical server, network and telecommunications equipment. 3U rackmount form factor with an

installed depth of 26 inches. Expandable battery runtime with optional BP72V15-2U and BP72V28RT-3U external battery packs. Full time sine wave

110 or 120V +. -2% output. Uninterruptible Power Supply (UPS) actively converts raw incoming AC power to DC, then re-converts output back to

completely regulated, filtered AC output. Operates continuously without using battery power during brownouts to 65V and overvoltages to 138V.

Highly efficient operation in optional economy mode setting, saving BTU heat output and energy costs. NEMA L5-30P input plug. NEMA 5-15, NEMA

5-15. 20R and NEMA L5-30R output receptacles. Network-grade AC surge and noise suppression. Zero transfer time between AC and battery

operation. Network management interfaces support simultaneous communications via USB port, DB9 serial port and SNMPWEBCARD slot.

Includes USB and DB9 serial ports. Built-in DB9 port offers both enhanced RS-232 enabled monitoring data, plus contact closure monitoring ability.

HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X. Supports

simultaneous detailed monitoring of equipment load levels, self-test data and mains power conditions via all 3 network interfaces at once. Includes

PowerAlert monitoring software and complete cabling. Emergency Power Off (EPO) interface. Integrated two bank PDU switching supports load

shedding and remote-reboot of connected equipment. 3 stage metered current monitoring and battery charge status LEDs. Dataline surge

suppression for dialup, DSL or network ethernet connection. Mains power and voltage regulation LEDs. Audible Alarm. Self-test. Fault-tolerant

auto-bypass mode. LED display panel easily rotates for better viewing in rackmount or tower configurations. 4 post rackmount accessories.

2-9USTAND tower kit and 2POSTRMKITWM two post rackmount hardware accessories available. Field replaceable, hot swappable internal

batteries and external battery packs. Attractive all-black UPS design. Two year warranty with $250,000 connected equipment insurance. Extended

warranty and service contracts available.

Applications

Ideal for protection of critical 120V equipment in server rooms, internetworking closets and telecommunications systems in rackmount or

tower applications. Common applications include corporate or departmental servers, workstations, hubs, routers, bridges, CAD/CAM

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - SYSTEM OVERVIEW

workstations, concentrators, IP telephony and traditional PBX switching systems. Package Includes SU3000RTXL3U UPS System PowerAlert Software and Cabling Mounting hardware for 4 post rack enclosures Instruction manual with warranty information Features SmartOnline high performance UPS system is idea...

Page 3 - Via 40A input breaker; INPUT; less than 6 hours to 90%; VOLTAGE REGULATION

Outlet quantity /type 4 NEMA 5-15R, 4 NEMA 5-15/20R, 1 NEMA L5-30R Customized loadmanagementreceptacles 2 controllable load banks support load shedding and remote reboot on demand of locked network devices (each bank has4 outlets) Overloadprotection Via 40A input breaker INPUT Maximum inputamps 24A ...

Page 4 - Yes; PHYSICAL; Steel; Cooling method; Yes, includes PowerAlert software CD-ROM and complete cabling; SNMP compatibility

EMI / RFI AC noisesuppression Yes PHYSICAL Shipping weight(lbs) 112.44 Shipping weight(kg) 55.53 ShippingDimensions(HWD/in) 11.25 x 23 x 31.5 ShippingDimensions(HWD/cm) 28.5 x 58.4 x 79.3 Unit weight (lbs) 73.85 Unit weight (kg) 33.49 Unit Dimensions(HWD/in) 5.25 x 17.75 x 26 Unit Dimensions(HWD/cm)...

Other Tripp Lite Models

All Tripp Lite Other