Tripp Lite SU1500RTXL2UA - Manual

Tripp Lite SU1500RTXL2UA

Tripp Lite SU1500RTXL2UA – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
Page: / 6

Table of Contents:

  • Page 2 – Features; Ultimate Lifetime Insurance; Specifications; SYSTEM OVERVIEW
  • Page 4 – Steel; Cooling method; Yes, includes PowerAlert software CD-ROM and complete cabling; SNMP compatibility
  • Page 5 – Related Items
  • Page 6 – Tower Stands; Tower Stand - Expandable Tower Base Stand UPS Accessory
Loading the manual

Tripp Lite

1111 West 35th Street

Chicago, IL 60609 USA

Telephone: +(773) 869 1234

E-mail:

[email protected]

Model #: SU1500RTXL2UA

SmartOnline Expandable 2U Rack/Tower UPS System - On-line, double-conversion, sine wave UPS with PDU
switching, current monitoring and fault tolerant auto-bypass

Highlights

1500VA/1.5kVA online, double-conversion, extended-run 2U rack/tower UPS

Zero transfer time, on-line, double-conversion and economy-mode operation

supported

Maintains sine-wave 100/110 or 120V +/-2% output during overvoltages to

138V and brownouts as low as 65V (50/60Hz auto-sensing)

Simultaneous communications via HID-compliant USB port, serial port,

SNMP/Web card slot and EPO interface

Fault tolerant auto-bypass mode, current monitoring and switched PDU control

via 2 switchable output load banks

Input: NEMA 5-15P (120V). Output: 6 NEMA 5-15R (120V).

2-year product warranty; $250,000

Ultimate Lifetime Insurance

(USA &

Canada only)

Description

1500VA online, double-conversion UPS system for critical server, network and telecommunications equipment. 2U rackmount form factor with an

installed depth of only 19 in. Expandable battery runtime with optional BP48V24-2U and BP48V60RT-3U external battery packs. Full-time sine wave

100, 110 or 120V +/-2% output. Uninterruptible Power Supply (UPS) actively converts raw incoming AC power to DC, then re-converts output back to

completely regulated, filtered AC output. Operates continuously without using battery power during brownouts to 65V and overvoltages to 138V.

Highly efficient operation in optional economy mode setting, saving BTU heat output and energy costs. NEMA 5-15P input plug and NEMA 5-15R

output receptacles. Network-grade AC surge and noise suppression. Zero transfer time between AC and battery operation. Network management

interfaces support simultaneous communications via USB port, DB9 serial port and SNMPWEBCARD slot. HID-compliant USB interface enables

integration with built-in power management and auto shutdown features of Windows and Mac OS X. Supports simultaneous detailed monitoring of

equipment load levels, self-test data and utility power conditions via all 3 network interfaces simultaneously. Includes PowerAlert monitoring software

and complete cabling. Emergency Power Off (EPO) interface. Integrated two-bank PDU switching supports load shedding and remote reboot of

connected equipment. Three-stage metered current monitoring and battery charge status LEDs. LED display panel easily rotates for better viewing

in rackmount or tower configurations.Dataline surge suppression for dialup, DSL or network ethernet connection. Utility power and voltage regulation

LEDs. Audible alarm. Self-test. Fault-tolerant auto-bypass mode. 4-post rackmount accessories included; 2-9USTAND tower kit and

2POSTRMKITWM 2-post rack & wallmount accessories available. Field replaceable, hot-swappable internal batteries and external battery packs.

Attractive all-black color scheme. Two-year warranty and $250,000

connected equipment insurance

; extended warranty and service contracts

available.

Applications

Ideal for protection of critical 120V equipment in server rooms, internetworking closets and telecommunications systems in rackmount or

tower applications. Common applications include corporate or departmental servers, workstations, hubs, routers, bridges, CAD/CAM

workstations, concentrators, IP telephony and traditional PBX switching systems.

Package Includes

SU1500RTXL2Ua Online Double-Conversion UPS System

PowerAlert Software and cabling

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Features; Ultimate Lifetime Insurance; Specifications; SYSTEM OVERVIEW

PowerAlert Software and cabling Mounting hardware for 4 post rack enclosures Instruction manual with warranty information Features SmartOnline high-performance UPS system is ideal for critical voice, data, medical and industrial network applications True on-line, double-conversion UPS provides perfe...

Page 4 - Steel; Cooling method; Yes, includes PowerAlert software CD-ROM and complete cabling; SNMP compatibility

Shipping weight(lbs) 54 Shipping weight(kg) 24.5 ShippingDimensions(HWD/in) 9.75 x 20.25 x 24 ShippingDimensions(HWD/cm) 24.8 x 51.4 x 61 Unit weight (lbs) 44.1 Unit weight (kg) 20 Unit Dimensions(HWD/in) 3.5 x 17.5 x 19 Unit Dimensions(HWD/cm) 8.9 x 44.4 x 48.3 Material ofconstruction Steel Form fa...

Page 5 - Related Items

Cold Start Inverter can be cold started to enable temporary AC output during a power failure Appearance Attractive all-black color scheme BATTERY PACK ACCESSORY (optional) Battery PackAccessory(optional) BP48V24-2U, BP48V60RT3U (optional) CERTIFICATIONS C e r t i f i c a t i o n s Tested to UL1778 (...

Other Tripp Lite Models

All Tripp Lite Other