Page 2 - Copyright; All rights reserved; Trademarks; could result in death or serious injury.
Copyright © 20 08 Trane All rights reserved This document and the information in it are the property of Trane and may not be used or reproduced in whole or in part, without the written permission of Trane. Trane reserves the right to revise this publication at any time and to make changes to its con...
Page 3 - Table of Contents
Table of Contents BAS-SVX10C-EN 3 General Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Part Numbers . . . . ....
Page 5 - General Information; Product Description
BAS-SVX10C-EN 5 General Information This section provides a description of the wired temperature sensors, as well as part numbers and dimensions. Product Description Note: The information in this manual applies to both factory and field installed versions of Trane wired temperature sensors. Trane ® ...
Page 6 - Part Numbers
6 BAS-SVX10C-EN General Information Part Numbers The following table lists part numbers for each sensor type. The following table lists part numbers for optional accessories. Sensor type Features Part number BAYSENS Global parts Setpoint Fan control System Occupancy LEDs Temperature sensors Single N...
Page 7 - Dimensions
BAS-SVX10C-EN 7 General Information Dimensions The following illustration provides specific dimension details. The dimensions are the same for all models. 2.9 in (73.5 cm) 1.08 in (27.5 mm) 4.68 in (118.9 mm) 1.45 in (36.8 mm) 0.63 in (15.9 mm) 0.31 in (8 mm) 0.12 in (3 mm) TYP R.07 in (R1.9) mm) 3....
Page 9 - Installation and Configuration: Display Sensor; Mounting the Back Plate; WARNING; NOTICE
BAS-SVX10C-EN 9 Installation and Configuration: Display Sensor This section provides step-by-step installation instructions for the display sensor (see applicable part numbers for the temperature sensor with LCD display on p. p. 6 ). For installation of all other sensor models, see p. 17 . Read thro...
Page 10 - Wiring the Sensor; Attaching the terminal block to the pins on the circuit board
10 BAS-SVX10C-EN Installation and Configuration: Display Sensor Wiring the Sensor WARNING Hazardous voltage! Disconnect all electric power, including remote disconnects before servicing. Follow proper lockout/tagout procedures to ensure the power cannot be inadvertently energized. Failure to disco...
Page 11 - Configuring the Display Sensor; Configuration Procedure
BAS-SVX10C-EN 11 Installation and Configuration: Display Sensor Configuring the Display Sensor The configuration of the display sensor determines which system features can be accessed and changes can be made by the tenant (for example, changes to cooling/heating mode, setpoint, or fan speed. Verify ...
Page 15 - Optional Configuration Features; Displaying Setpoint or Temperature; Locking or Unlocking Settings
BAS-SVX10C-EN 15 Installation and Configuration: Display Sensor Optional Configuration Features Displaying Setpoint or Temperature You can configure the sensor to display either the temperature (default) or setpoint. To select either option: 1. Verify that the sensor is in operating mode and at the ...
Page 16 - Replacing the Cover
16 BAS-SVX10C-EN Installation and Configuration: Display Sensor 3. Press the left and right arrows for 4 seconds. The lock symbol will appear on the display to indicate that the setting has been locked. Note: If you try to access a feature that is locked, the locked symbol appears on the display. If...
Page 17 - Installation: All Models Other Than the Display Sensor
BAS-SVX10C-EN 17 Installation: All Models Other Than the Display Sensor This section provides step-by-step installation instructions for all sensor models other than the display sensor. (For installation of the display sensor, see p. 9 .) Read through the pre-installation information before proceedi...
Page 21 - Changing the Setpoint Thumb Wheel (optional)
BAS-SVX10C-EN 21 Installation: All Models Other Than the Display Sensor Changing the Setpoint Thumb Wheel (optional) Sensors with temperature setpoint control have pre-installed Fahrenheit setpoint thumb wheels. A Celsius setpoint thumb wheel is included with these sensors. An optional hot/cold setp...
Page 23 - Operation; Changing Temperature Settings; Changing System Settings; Changing Fan Settings
BAS-SVX10C-EN 23 Operation This section describes sensor operations. Changing Temperature Settings To change temperature settings: • For sensors with temperature setpoint thumb wheels (located on top of the sensor), rotate the thumb wheel to the desired temperature setting. Note: If you need to chan...
Page 24 - Selecting Temporary Occupancy (Timed Override); Sensors with Occupied/Unoccupied buttons; Display Sensors; Locations of Occupied button and Unoccupied buttons
24 BAS-SVX10C-EN Operation Selecting Temporary Occupancy (Timed Override) Temporary occupancy (timed override) is available on some sensors. Temporary occupancy can be selected to adjust temperature, fan, or heat/cool settings after the system has changed to unoccupied mode. System control will reve...
Page 25 - Service Pin Request; Sensors with Occupied/Unoccupied Buttons; Location of keys for service pin request
BAS-SVX10C-EN 25 Operation Service Pin Request Some sensor models can communicate a service pin request to their connected unit controller. Sensors with Occupied/Unoccupied Buttons To initiate a service pin request, press the Occupied button ( Figure 2, p. 24 ) for 10–25 seconds. The following occur...
Page 26 - Sensors with Thumb Wheels; Display Sensor; Star/Double star on thumb wheel
26 BAS-SVX10C-EN Operation Star(*)/Double Star(**) Function The star/double star function is available on sensor models with thumb wheels and on the display sensor. Note: Consult the appropriate unit controller documentation for information about this function. Sensors with Thumb Wheels Turning the ...
Page 27 - Display Sensor Operation; Display sensor in operating mode
BAS-SVX10C-EN 27 Operation Display Sensor Operation This section describes display sensor operation. Figure 5 shows an example of a display sensor that has been configured and is in operating mode. Changing Temperature Settings Changing Heating and Cooling Temperature Settings (dual setpoint systems...
Page 29 - Maintenance and Troubleshooting; LEDs
BAS-SVX10C-EN 29 Maintenance and Troubleshooting This section describes sensor features that can be used for maintenance and troubleshooting. LEDs Some sensor models have LEDs. They are located on the front cover and convey the following information: Error Codes (Display Sensor) For an explanation o...
Page 30 - Measuring Output Resistance
30 BAS-SVX10C-EN Maintenance and Troubleshooting Measuring Output Resistance Measure output resistance as follows, according to sensor type. Display Sensors For display sensors, measure the outputs for zone temperature, setpoints, heat setpoint, and system/fan mode as described: 1. Ensure that the G...
Page 31 - Resistance measurements for zone temperature and setpoints; Resistance measurements for fan and system modes
BAS-SVX10C-EN 31 Maintenance and Troubleshooting Table 1. Resistance measurements for zone temperature and setpoints Zone or setpoint temperature Nominal zone temperature output resistance Nominal setpoint and heating setpoint output resistance ** NA 938 Ω 55°F (12.8°C) 17.47 k Ω 792 Ω 60°F (15.6°C)...
Page 32 - Cleaning the Sensor; Replacing the Thumb Wheel
32 BAS-SVX10C-EN Maintenance and Troubleshooting Cleaning the Sensor NOTICE Equipment damage! Spraying glass cleaner or any other solution directly on the sensor may damage it. You can clean the sensor by applying glass cleaner to a soft, non-abrasive cloth, and gently wiping the face, including the...
Page 33 - Wiring Diagrams
BAS-SVX10C-EN 33 Wiring Diagrams Each wiring diagram is identified by sensor part number (see “Part Numbers,” p. 6 for reference.) For wiring information for the display sensor, see Figure 1, p. 10 . TimedoverrideUnoccupied(Cancel) SW2 R1, 1.5 k Ω TimedoverrideOccupied(On) SW1 RT1thermistor,10 k at ...
Page 34 - Signal common; Temperature sensors with fan control
34 BAS-SVX10C-EN Wiring Diagrams TimedoverrideCancel SW2 R1, 1.5 k Ω Timed overrideOn SW1 Zonetemperature Signal common 1 2 RT1 thermistor,10 k at 25°C Ω Dwg source: 3270 3438 Ti m ed overrideCancel S W 4 R9, 1.5 k W Ti m ed overrideOn S W 3 Ther m istor, 10 k at 25°C W 1 2 4 CalibrationPot 1 (see )...
Page 40 - COMM Module; Optional COMM module
40 BAS-SVX10C-EN Wiring Diagrams 2 (+) 1 (–) COMM Module J1 23 Optional COMM module X1365146702
Page 41 - Specifications and Agency Compliance; Agency Compliance; Specifications
BAS-SVX10C-EN 41 Specifications and Agency Compliance Agency Compliance • United States: – UL listed: 94, 5 VA Flammability rating; 916, Energy management equipment – FCC Part 15, Subpart B • Canada: – CUL listed: 916, Energy management equipment • Europe: – CE marked Specifications Sensor operating...
Page 42 - CE Declaration of Conformity
42 BAS-SVX10C-EN Specifications and Agency Compliance CE Declaration of Conformity Manufacturer: Trane, 4833 White Bear Parkway, Saint Paul, MN 55103, USA Product: Wired display sensor Model number: X1379088601, X1379088604, X1379088605 The manufacturer hereby declares that the product conforms to t...