Trane UNT-SVX07A-EN - Manual

Trane UNT-SVX07A-EN

Trane UNT-SVX07A-EN – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
45 Page 45
46 Page 46
47 Page 47
48 Page 48
49 Page 49
50 Page 50
51 Page 51
52 Page 52
53 Page 53
54 Page 54
55 Page 55
56 Page 56
57 Page 57
58 Page 58
59 Page 59
60 Page 60
61 Page 61
62 Page 62
63 Page 63
64 Page 64
65 Page 65
66 Page 66
67 Page 67
68 Page 68
69 Page 69
70 Page 70
71 Page 71
72 Page 72
73 Page 73
74 Page 74
75 Page 75
76 Page 76
77 Page 77
78 Page 78
79 Page 79
80 Page 80
Page: / 80

Table of Contents:

  • Page 2 – Warnings and Cautions
  • Page 3 – contents; Installation .....................................................................2
  • Page 4 – General; Smaller unit footprint
  • Page 5 – Installation; Digit 4 — development sequence “B”; extended end pocket; Digits 10, 11 — design sequence; Model Number Description
  • Page 6 – Digits 37, 38 — future cntrl functions; ”standard vertical recessed panel
  • Page 8 – Available Models
  • Page 9 – Factory-Installed Piping Packages
  • Page 10 – Vertical Concealed, Model A
  • Page 11 – Vertical Cabinet, Model B
  • Page 12 – Horizontal Concealed, Model C
  • Page 13 – Horizontal Cabinet, Model D
  • Page 14 – Horizontal Recessed, Model E
  • Page 15 – Vertical Wall Hung Cabinet, Model F
  • Page 16 – Vertical Recessed, Model H
  • Page 17 – Vertical Slope Top, Model J
  • Page 18 – Low Vertical Concealed, Model K
  • Page 19 – Low Vertical Cabinet, Model L
  • Page 20 – Inverted Vertical Cabinet, Model M
  • Page 21 – Inverted Vertical Recessed, Model N
  • Page 26 – Wall Box
  • Page 27 – Projection Panel
  • Page 28 – WARNING; Receiving and Handling; Cover the entire unit with a canvas; Installation Preparation
  • Page 29 – Service Access; Verify the unit size and tagging with the
  • Page 30 – Duct Connections; Piping Considerations
  • Page 32 – connections
  • Page 33 – If the piping package has modulating
  • Page 35 – Steam Piping
  • Page 36 – Unit Wiring Diagrams
  • Page 41 – Installing the Unit; Vertical Units
  • Page 42 – The trim ring assembly cannot; CAUTION
  • Page 43 – Wall-Mounted Control Options
  • Page 45 – Installation Checklist
  • Page 46 – Device Addressing
  • Page 47 – Pre-Startup Checklist
  • Page 48 – Refer to the Trane publication,; startup; than 55°F and less than 85°F.
  • Page 49 – Operation; General Information
  • Page 50 – Fan Mode Switch Operation; Tracer ZN520 Operation
  • Page 51 – input values to detemine initial values.; Binary Inputs; Binary Outputs
  • Page 53 – • By pressing the zone sensor’s timed
  • Page 54 – Cooling Operation; ZN520 controller attempts to; Heating Operation; During heating mode, the Tracer
  • Page 55 – Fan Mode Operation; ZN520 controller offers additional; ZN520 does not support fan
  • Page 57 – building
  • Page 60 – Diagnostics
  • Page 64 – Position 2 indicates Tracer ZN520.
  • Page 65 – Red SERVICE LED; second
  • Page 67 – Maintenance; Maintenance Procedures; Remove the overflow drain line to the; Main Drain Pan
  • Page 71 – CSTI Fan Speed Switch
  • Page 72 – CSTI Non Fan Speed Switch
  • Page 73 – Line voltage fan speed switch
  • Page 74 – Tracer ZN010 with electric heat
  • Page 75 – Tracer ZN510 with main and auxilliary valves
  • Page 76 – ZN520 with 2-stage electric heat
  • Page 80 – US
Loading the manual

UNT-SVX07A-EN

Installation, Operation,
and Maintenance

UniTrane Fan-Coil & Force Flo
Air Conditioners

200 to 1,200 cfm

Models FC & FF
“ZO” and later design sequence

Low vertical models FCKB & FCLB:
“SO” and later design sequence

April 2005

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Warnings and Cautions

© 2005 American Standard Inc. UNT-SVX07A-EN About This ManualLiterature Change History Use this manual for UniTrane fan-coilsand Force Flo cabinet heaters. This is theseventh revision of this manual. Itprovides specific installation, operation,and maintenance instructions for “ZO”and later design se...

Page 3 - contents; Installation .....................................................................2

UNT-SVX07A-EN 3 contents Cross reference to related publications/information for UniTrane™ fan-coil & ForceFlo™ equipment:• Rover™ Installation, Operation and Programming Guide, EMTX-SVX01D-EN• Tracer™ ZN510 Unit Controller, CNT-IOP-1• Tracer™ ZN520 Unit Controller, CNT-SVX04A-EN• UniTrane™ Fan-...

Page 4 - General; Smaller unit footprint

4 UNT-SVX07A-EN Figure I-GI-1. UniTrane fan-coil unit components. Vertical cabinet model is shown. General UniTrane fan-coil and Force Flo units areintended for single zone applications.These units have load capabilities of 200to 1200 cfm. See Figure I-GI-1 for unitcomponents. Fan-coil units are ava...

Other Trane Models