Toshiba MMK-AP0072H - Manual

Toshiba MMK-AP0072H

Toshiba MMK-AP0072H – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
Page: / 29

Table of Contents:

  • Page 2 – ÕÉÏÈÅÔÇÓÇ ÍÅÏÕ ØÕÊÔÉÊÏÕ; HFC
  • Page 3 – ÐÅÑÉÅ×ÏÌÅÍÁ; ÅËËÇÍÉÊÁ
  • Page 4 – Accessory parts and parts to be procured locally; Accessory parts; Refrigerant piping; attached to the indoor unit of the air conditioner, and use it.
  • Page 5 – PRECAUTIONS FOR SAFETY; New Refrigerant Air Conditioner Installation; CAUTION; To Disconnect the Appliance from Main Power Supply; WARNING; • Connect the connecting wire correctly.; ENGLISH
  • Page 6 – applied to the terminals from affecting the terminals.; SELECTION OF INSTALLATION PLACE; Avoid installing in the following places.
  • Page 7 – Installation place; • A place where there is no obstacle near the air inlet and outlet.
  • Page 8 – INSTALLATION OF INDOOR UNIT; REQUIREMENT; Be careful to the following items when installing the unit.; OK
  • Page 9 – CUTTING A HOLE AND MOUNTING INSTALLATION PLATE; When the installation plate is directly mounted on the wall; NOTE; GOOD
  • Page 10 – PIPING AND DRAIN HOSE INSTALLATION; Piping and drain hose forming; Changing drain hose
  • Page 11 – In case of right or left piping; In case of bottom right or bottom left piping; • After scribing slits of the front panel with a knife or a; Left- hand connection with piping; Bend the connection pipe within a radius of 30 mm.; To connect the pipe after installation of the unit (figure)
  • Page 13 – REFRIGERANT PIPING; Piping material; Gas side; Phosphor deoxidization joint-less pipe for air conditioner; Pipe Forming/End Positioning; Flaring
  • Page 14 – • Projection margin in flaring :; Connection of refrigerant pipe; • Since the atmospheric pressure only is sealed as the; Open fully valves of the outdoor unit
  • Page 15 – ELECTRIC WORK; Power supply specifications; Cables and remote controller wires are procured locally.
  • Page 16 – Wiring connection; How to connect the power cable
  • Page 17 – Wiring connection for flow selector unit; How to connect the wiring of flow selector unit; Remove the four screws securing the front panel.
  • Page 18 – • Strip off approx. 14mm cover of the wire to be connected.; Wiring between indoor and outdoor units
  • Page 19 – APPLICABLE CONTROLS; NOTIFICATION; • Automatic address; Exchange of applicable control setup; Basic operation procedure for setup exchange; Change the setup while operation of the equipment stops.
  • Page 20 – Change of lighting time of filter sign; To secure better effect of heating; Adjustment of air direction
  • Page 21 – In case of wired remote controller; TEST RUN; Before test operation
  • Page 22 – For the operation procedure, be sure to follow the Owner’s Manual.; • Check wiring/piping of indoor and outdoor units
  • Page 23 – TROUBLESHOOTING; Confirmation and check; The check code is only displayed during the operation.; Confirmation of error history
  • Page 24 – Terminology
  • Page 26 – Error detected by TCC-LINK central control device
  • Page 27 – New check code; Difference between the new check code and the current system; • Block display of combination of [
  • Page 28 – WARNINGS ON REFRIGERANT LEAKAGE; Check of Concentration Limit
  • Page 29 – CONFIRMATION OF INDOOR UNIT SETUP
Loading the manual

Indoor Unit
Unité intérieure
Raumeinheit
Unità interna
Unidad interior
Unidade interior
Binnenunit

ÅóùôåñéêÞ mïíÜäá

<High-Wall Type>
<Type mural haut>
<Wand modell>
<Tipo per mura alte>
<Tipo par te alta de la pared>
<Tipo para Parede Alta>
<Hogewandmodel>

<Ôýðïò ôïðïèåôçìÝíïõ øçëÜ óôïí ôïß÷ï>

MMK-AP0072H,
MMK-AP0092H,
MMK-AP0122H

INSTALLATION MANUAL

MANUEL D’INSTALLATION

INSTALLATIONS-HANDBUCH

MANUALE DI INSTALLAZIONE

MANUAL DE INSTALACIÓN

MANUAL DE INSTALAÇÃO

INSTALLATIE HANDLEIDING

ÅÃ×ÅÉÑÉÄÉÏ ÅÃÊÁÔÁÓÔÁÓÇÓ

SUPER MODULAR MULTI SYSTEM AIR CONDITIONER
SMMS CLIMATISEUR
SMMS KLIMAGERÄT
SMMS CONDIZIONATORE D'ARIA
SMMS APARATO DE AIRE ACONDICIONADO
SMMS AR CONDICIONADO
SMMS AIRCONDITIONER

SMMS

ÊËÉÌÁÔÉÓÔÉÊÏ

SMMS

For commercial use

(Not accessible to the general public)

Pour usage commercial

(Vente interdite au grand public)

Nur für gewerbliche Nutzung

(kein öffentlicher Zugang)

Per uso commerciale

(Non accessibile a clienti generici)

Para uso comercial

(no destinado al público en general)

Para uso comercial

(não acessível ao público em geral)

Voor commercieel gebruik

(niet geschikt voor huishoudelijk gebruik)

Ãéá åìðïñéêÞ ÷ñÞóç

(Ìç äéáèÝóéìï óôï åõñý êïéíü)

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - ÕÉÏÈÅÔÇÓÇ ÍÅÏÕ ØÕÊÔÉÊÏÕ; HFC

ADOPTION OF NEW REFRIGERANT This Air Conditioner is a new type which adopts a newrefrigerant HFC (R410A) instead of the conventionalrefrigerant R22 in order to prevent destruction of theozone layer. UTILISATION DU NOUVEAU REFRIGERANT Ce climatiseur est d’un type inédit qui utilise le nouveauréfrigér...

Page 3 - ÐÅÑÉÅ×ÏÌÅÍÁ; ÅËËÇÍÉÊÁ

CONTENTS SOMMAIRE INHALT INDICE CONTENIDO ÍNDICE ÐÅÑÉÅ×ÏÌÅÍÁ INHOUD ITALIANO ESPA Ñ OL PORTUGU Ê S ÅËËÇÍÉÊÁ FRANCAIS DEUTSCH NEDERLANDS ENGLISH Accessory parts and parts to be procured locally ....................................... 1 1 PRECAUTIONS FOR SAFETY ...........................................

Page 4 - Accessory parts and parts to be procured locally; Accessory parts; Refrigerant piping; attached to the indoor unit of the air conditioner, and use it.

1 Accessory parts and parts to be procured locally H Accessory parts H Parts to be procured locally Connecting pipe (Liquid side)(6.4mm (diam.), Nominal (diam.) 1/4” thick 0.8mm)MMK-AP0072H to MMK-AP0122H Connecting pipe (Gas side)(9.5mm (diam.), Nominal (diam.) 3/8” thick 0.8mm)MMK-AP0072H to MMK-A...

Other Toshiba Models