Page 2 - Printed in the United States of America
The information in this User’s Manual has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for any inaccuracies that may be contained in this document, makes no commitment to update or to keep current the information in this manual, or to notify any person...
Page 3 - iii; Preface; About This Manual
iii Preface Preface About This Manual T h i s m a n u a l i s w r i t t e n f o r s y s t e m i n t e g r a t o r s , P C t e c h n i c i a n s a n d knowledgeable PC users. It provides information for the installation and use of the X6DH3-G2/X6DHi-G2 motherboard. The X6DH3-G2/X6DHi-G2 supports sing...
Page 4 - iv; Overview; Chapter 2: Installation; Table of Contents
iv Preface About This Manual ...................................................................................................... iii Manual Organization ................................................................................................... iii Conventions Used in this Manual ...........
Page 5 - Chapter 3: Troubleshooting; Procedures
v Power Button .......................................................................................... 2-13 Chassis Intrusion .................................................................................... 2-14 Serial Ports .......................................................................
Page 7 - Chapter 1: Introduction; Chapter; Checklist
Chapter 1: Introduction 1-1 Chapter 1 Introduction 1-1 Overview Checklist Congratulations on purchasing your computer motherboard from an acknowledged leader in the industry. Supermicro boards are designed with the utmost attention to detail to provide you with the highest standards in quality and p...
Page 8 - Contacting Super Micro; Headquarters; Super
1-2 X6DH3-G2/X6DHi-G2 User's Manual Contacting Super Micro Headquarters Address: Super Micro Computer, Inc. 980 Rock Ave. San Jose, CA 95131 U.S.A. Tel: +1 (408) 503-8000 Fax: +1 (408) 503-8008 Email: [email protected] (General Information) [email protected] (Technical Support) Web Site:...
Page 12 - Motherboard Features
1-6 X6DH3-G2/X6DHi-G2 User's Manual Motherboard Features CPU • Single or dual Intel ® Xeon TM EM64T processors at 800 MHz front side (system) bus speed with support of Hyper-Threading (HT), EM64T and Enhanced Intel SpeedStep (EIST) Using the EM64T Feature • Install a 64-bit OS (Windows XP Profession...
Page 14 - Figure 1-9. Block Diagram of the E7520 Chipset
1-8 X6DH3-G2/X6DHi-G2 User's Manual Figure 1-9. Block Diagram of the E7520 Chipset Note: This is a general block diagram. Please see the previous Motherboard Features pages for details on the features of the motherboard. MCH 4_DDRII_400 4_DDRII_400 DIMMs DIMMs 6300 ESB FWH FWH LPC I/O LPC I/O LPC BU...
Page 15 - System Features; Interface, and Integrated System Management Controller.; ICH System Features; The 6300ESB ICH system consists of:
Chapter 1: Introduction 1-9 1-2 Chipset Overview Built upon the functionality and the capability of the 7520 chipset, The X6DH3- G2/X6DHi-G2 motherboard provides the performance and feature set required for dual processor-based servers, with confi guration options optimized for communica- tions, pres...
Page 16 - Features; Recovery from AC Power Loss; change this setting. The default setting is Last State.; Health; PC health monitoring.; Fan Status Monitor via BIOS and SDIII; the chassis temperature is too high.; CPU Fan Auto-Off in Sleep Mode; full power, thereby generating less heat.
1-10 X6DH3-G2/X6DHi-G2 User's Manual 1-3 Special Features Recovery from AC Power Loss BIOS provides a setting for you to determine how the system will respond when AC power is lost and then restored to the system. You can choose for the system to remain powered off (in which case you must hit the po...
Page 17 - CPU Overheat LED and Fan Fail Control; alerted of the potential problem.; Windows Server 2003 Operating Systems.; Slow Blinking LED for Suspend-State Indicator; the BIOS Setup routine.
Chapter 1: Introduction 1-11 CPU Overheat LED and Fan Fail Control This feature is available when the user enables the CPU overheat/Fan Fail warn- ing function in the BIOS. This allows the user to defi ne an overheat temperature. When this temperature is exceeded, both the overheat fan and the warnin...
Page 18 - External Modem Ring-On; Supply; details on connecting the power supply.
1-12 X6DH3-G2/X6DHi-G2 User's Manual External Modem Ring-On Wake-up events can be triggered by a device such as the external modem ringing when the system is in the SoftOff state. Note that external modem ring-on can only be used with an ATX 2.01 (or above) compliant power supply. Wake-On-LAN (WOL) ...
Page 21 - Chapter 2; Devices; Precautions; • Use a grounded wrist strap designed to prevent static discharge.; Unpacking
Chapter 2: Installation 2-1 Chapter 2 Installation 2-1 Static-Sensitive Devices Electric-Static-Discharge (ESD) can damage electronic com ponents. To prevent damage to your system board, it is important to handle it very carefully. The following measures are generally suffi cient to protect your equi...
Page 22 - before; -2 Xeon Processor and Heatsink Installation; CPU Installation
2-2 X6DH3-G2/X6DHi-G2 User's Manual IMPORTANT: Always connect the power cord last and always remove it before add- ing, removing or changing any hardware components. Make sure that you install the processor into the CPU socket before you install the CPU heatsink. 2-2 Xeon Processor and Heatsink Inst...
Page 23 - CEK Heatsink Installation
Chapter 2: Installation 2-3 CEK Passive Heatsink Screw#1 Screw#2 Screw#1 1. Do not apply any thermal grease to the heatsink or the CPU die-the required amount has already been applied. 2. Place the heatsink on top of the CPU so that the four mounting holes are aligned with those on the retention mec...
Page 24 - To Un-install the Heatsink
2-4 X6DH3-G2/X6DHi-G2 User's Manual (Warning: We do not recommend that the CPU or the heatsink be removed. However, if you do need to uninstall the heatsink, please follow the instructions below to uninstall the heatsink to prevent damage done to the CPU or the CPU socket.) 1. Unscrew and remove the...
Page 25 - Figure 2-1. PGA604 Socket: Empty and with Processor Installed; Mounting the Motherboard in the Chassis
Chapter 2: Installation 2-5 Figure 2-1. PGA604 Socket: Empty and with Processor Installed Mounting the Motherboard in the Chassis All motherboards have standard mounting holes to fi t different types of chassis. Make sure that the locations of all the mounting holes for both the motherboard and the c...
Page 26 - DIMMs; Check the Supermicro web site for recommended memory modules:; CAUTION; Exercise extreme care when installing or removing DIMM modules; Memory; The X6DH3-G2/X6DHi-G2 supports up to 16 GB Registered ECC DDR2
2-6 X6DH3-G2/X6DHi-G2 User's Manual 2-3 Installing DIMMs ( Note: Check the Supermicro web site for recommended memory modules: http:www. supermicro.com/) CAUTION Exercise extreme care when installing or removing DIMM modules to prevent any possible damage. Also note that the memory is inter- leaved ...
Page 27 - DDR 2 Slot; Panel; Video; Figure 2-2. Installing and Removing DDR 2
Chapter 2: Installation 2-7 DDR 2 Slot Release Tab Release Tab To Remove: Use your thumbs to gently push near the edge of both ends of the module. This should release it from the slot. 2-4 I/OPorts/Control Panel Connectors The I/O ports are color coded in conformance with the PC 99 specifi cation. Se...
Page 28 - Front Control Panel; for descriptions and pin defi nitions.
2-8 X6DH3-G2/X6DHi-G2 User's Manual Front Control Panel JF1 contains header pins for various buttons and indicators that are normally located on a control panel at the front of the chassis. These connectors are designed specifi - cally for use with Supermicro server chassis. See Figure 2-4 for the de...
Page 29 - Cables; ATX Power Connector
Chapter 2: Installation 2-9 LAN1 ® JLAN 1 S UPER X6DH3-G2 LAN2 DIMM 2A DIMM 2B DIMM 3A DIMM 3B DIMM 4A DIMM 4B DIMM 1B DIMM 1A 12V 8-pin PWR JF 1 FP Control JOH IPMI ID E2 Flo pp y BIOS Fan4 SMB PCI-X100 MHz PCI-X 100 MHz ZCR (Green Slot) PCI-X 133 MHz Battery JPL1 PCI-E X8 VGA COM1 USB 0/1 KB/MS Fa...
Page 32 - Power Fail LED
2-12 X6DH3-G2/X6DHi-G2 User's Manual Power Button OH/Fan Fail LED 1 NIC1 LED Reset Button 2 Power Fail LED HDD LED Power LED Reset Pwr Vcc Vcc Vcc Vcc Ground Ground 19 20 Vcc X Ground NMI X Vcc NIC2 LED Overheat/FanFail LED Connect an LED to the OH/Fan Fail connection on pins 7 and 8 of JF1 to provi...
Page 34 - Serial Ports
2-14 X6DH3-G2/X6DHi-G2 User's Manual LAN1 ® JLAN 1 S UPER X6DH3-G2 LAN2 DIMM 2A DIMM 2B DIMM 3A DIMM 3B DIMM 4A DIMM 4B DIMM 1B DIMM 1A 12V 8-pin PWR JF 1 FP Control JOH IPMI ID E 2 Flo ppy BIOS Fan4 SMB PCI-X100 MHz PCI-X 100 MHz ZCR (Green Slot) PCI-X 133 MHz Battery JPL1 PCI-E X8 VGA COM1 USB 0/1...
Page 36 - mouse are located next to the rear
2-16 X6DH3-G2/X6DHi-G2 User's Manual LAN1 ® JLAN 1 S UPER X6DH3-G2 LAN2 DIMM 2A DIMM 2B DIMM 3A DIMM 3B DIMM 4A DIMM 4B DIMM 1B DIMM 1A 12V 8-pin PWR JF1 FP Control JOH IPMI IDE2 Floppy BIOS Fan4 SMB PCI-X100 MHz PCI-X 100 MHz ZCR (Green Slot) PCI-X 133 MHz Battery JPL1 PCI-E X8 VGA COM1 USB 0/1 KB/...
Page 37 - Fan Headers
Chapter 2: Installation 2-17 LAN1 ® JLAN 1 S UPER X6DH3-G2 LAN2 DIMM 2A DIMM 2B DIMM 3A DIMM 3B DIMM 4A DIMM 4B DIMM 1B DIMM 1A 12V 8-pin PWR JF 1 FP Control JOH IPMI IDE2 Flopp y BIOS Fan4 SMB PCI-X100 MHz PCI-X 100 MHz ZCR (Green Slot) PCI-X 133 MHz Battery JPL1 PCI-E X8 VGA COM1 USB 0/1 KB/MS Fan...
Page 41 - Power Supply Failure LED
Chapter 2: Installation 2-21 Overheat LED (JOH) The JOH header is used to connect an LED to provide warning of chas- sis overheating. It is located near the microphone connector. See the table on the right for pin defi nitions. Note: This feature is only available when using redundant Supermicro powe...
Page 42 - Settings; Explanation of
2-22 X6DH3-G2/X6DHi-G2 User's Manual 2-6 Jumper Settings Explanation of Jumpers To m o d i f y t h e o p e r a t i o n o f t h e m o t h e r b o a r d , j u m p e r s c a n b e used to choose between optional settings. Jumpers create shorts between two pins to change the function of the connector. P...
Page 43 - Watch Dog Enable; Do not
Chapter 2: Installation 2-23 LAN1 ® JLAN1 S UPER X6DH3-G2 LAN2 DIMM 2A DIMM 2B DIMM 3A DIMM 3B DIMM 4A DIMM 4B DIMM 1B DIMM 1A 12V 8-pin PWR JF 1 FP Control JOH IPMI IDE2 Floppy BIOS Fan4 S MB PCI-X100 MHz PCI-X 100 MHz ZCR (Green Slot) PCI-X 133 MHz Battery JPL1 PCI-E X8 VGA COM1 USB 0/1 KB/MS Fan6...
Page 46 - Jumper JP1 allows you to enable (force
2-26 X6DH3-G2/X6DHi-G2 User's Manual LAN1 ® JLAN1 S UPER X6DH3-G2 LAN2 DIMM 2A DIMM 2B DIMM 3A DIMM 3B DIMM 4A DIMM 4B DIMM 1B DIMM 1A 12V 8-pin PWR JF 1 FP Control JOH IPMI IDE2 Floppy BIOS Fan4 SMB PCI-X100 MHz PCI-X 100 MHz ZCR (Green Slot) PCI-X 133 MHz Battery JPL1 PCI-E X8 VGA COM1 USB 0/1 KB/...
Page 47 - GLAN LEDs; Indicators
Chapter 2: Installation 2-27 LAN1 ® JLAN1 S UPER X6DH3-G2 LAN2 DIMM 2A DIMM 2B DIMM 3A DIMM 3B DIMM 4A DIMM 4B DIMM 1B DIMM 1A 12V 8-pin PWR JF 1 FP Control JOH IPMI IDE2 Floppy BIOS Fan4 SMB PCI-X100 MHz PCI-X 100 MHz ZCR (Green Slot) PCI-X 133 MHz Battery JPL1 PCI-E X8 VGA COM1 USB 0/1 KB/MS Fan6 ...
Page 48 - Adaptec SAS Activity LED Indica-
2-28 X6DH3-G2/X6DHi-G2 User's Manual DS5 DS6 DS7 DS8 DS1 DS2 DS3 DS4 4 -7 2 LAN1 ® JLAN1 S UPER X6DH3-G2 LAN2 DIMM 2A DIMM 2B DIMM 3A DIMM 3B DIMM 4A DIMM 4B DIMM 1B DIMM 1A 12V 8-pin PWR JF1 FP Control JOH IPMI ID E 2 Floppy BIOS Fan4 SMB PCI-X100 MHz PCI-X 100 MHz ZCR (Green Slot) PCI-X 133 MHz Ba...
Page 49 - Parallel Port, Floppy, Hard Disk Drive and IPMI; • The fl oppy disk drive cable has seven twisted wires.
Chapter 2: Installation 2-29 LAN1 ® JLAN1 S UPER X6DH3-G2 LAN2 DIMM 2A DIMM 2B DIMM 3A DIMM 3B DIMM 4A DIMM 4B DIMM 1B DIMM 1A 12V 8-pin PWR JF1 FP Control JOH IPMI IDE 2 Floppy BIOS Fan4 SMB PCI-X100 MHz PCI-X 100 MHz ZCR (Green Slot) PCI-X 133 MHz Battery JPL1 PCI-E X8 VGA COM1 USB 0/1 KB/MS Fan6 ...
Page 50 - Floppy Connector
2-30 X6DH3-G2/X6DHi-G2 User's Manual Floppy Connector The fl oppy connector is located between the IDE connectors and the IPMI socket. See the table below for pin defi nitions. Floppy LAN1 ® JLAN1 S UPER X6DH3-G2 LAN2 DIMM 2A DIMM 2B DIMM 3A DIMM 3B DIMM 4A DIMM 4B DIMM 1B DIMM 1A 12V 8-pin PWR JF 1 F...
Page 51 - IDE Connectors; IDE Connectors are located
Chapter 2: Installation 2-31 LAN1 ® JLAN1 S UPER X6DH3-G2 LAN2 DIMM 2A DIMM 2B DIMM 3A DIMM 3B DIMM 4A DIMM 4B DIMM 1B DIMM 1A 12V 8-pin PWR JF 1 FP Control JOH IPMI IDE2 Floppy BIOS Fan4 SMB PCI-X100 MHz PCI-X 100 MHz ZCR (Green Slot) PCI-X 133 MHz Battery JPL1 PCI-E X8 VGA COM1 USB 0/1 KB/MS Fan6 ...
Page 52 - Notes
Page 53 - Chapter 3; Note: Always disconnect the power cord before adding,; Verify that all jumpers are set to their default positions.; No Video; for details on beep codes.
3-1 Chapter 3: Troubleshooting Chapter 3 Troubleshooting 3-1 Troubleshooting Procedures Use the following procedures to troubleshoot your system. If you have followed all of the procedures below and still need assistance, refer to the ‘Technical Support Procedures’ and/or ‘Returning Merchandise for ...
Page 54 - Losing the System’s Setup Confi guration; Support; NOTE; Memory Errors
3-2 X6DH3-G2/X6DHi-G2 User's Manual Losing the System’s Setup Confi guration 1. Make sure that you are using a high quality power supply. A poor quality power supply may cause the system to lose the CMOS setup information. Refer to Section 1-6 for details on recommended power supplies. 2. The battery...
Page 55 - Asked; do not; Warning
3-3 Chapter 3: Troubleshooting 2. BIOS upgrades can be downloaded from our web site at (http://www.supermicro. com/support/bios/ ). Note: Not all BIOS can be fl ashed; it depends on the modifi cations to the boot block code. 3. If you still cannot resolve the problem, include the following information...
Page 56 - What's on the CD that came with my motherboard?; Merchandise; maintenance of products.
3-4 X6DH3-G2/X6DHi-G2 User's Manual Question: What's on the CD that came with my motherboard? Answer: The supplied compact disc has quite a few drivers and programs that will greatly enhance your system. We recommend that you review the CD and install the applications you need. Applications on the C...
Page 57 - changes to the BIOS that may not be refl ected in this manual.; System BIOS; The BIOS is the Basic Input Output System used in all IBM; How To Change the Confi guration Data; Do not shut down or reset the system while updating the BIOS
Chapter 4: BIOS 4-1 Chapter 4 BIOS 4-1 Introduction This chapter describes the Phoenix BIOS™ Setup utility for the X6DH3-G2/X6DHi- G2. The Phoenix ROM BIOS is stored in a fl ash chip and can be easily upgraded using a fl oppy disk-based program. Note: Due to periodic changes to the BIOS, some settings...
Page 58 - Setup; Default settings are in bold text unless otherwise noted; Main BIOS Setup; detail how to navigate through the menus.
4-2 X6DH3-G2/X6DHi-G2 User's Manual 4-2 Running Setup * Default settings are in bold text unless otherwise noted . The BIOS setup options described in this section are selected by choosing the appropriate text from the main BIOS Setup screen. All displayed text is described in this section, although...
Page 59 - Main BIOS Setup Menu; Main Setup Features; System Time; This fi eld displays the date when this version of BIOS was built.; Legacy Diskette A; options are Disabled, Channel 0, Channel 1 and
Chapter 4: BIOS 4-3 Main BIOS Setup Menu Main Setup Features System Time To set the system date and time, key in the correct information in the appropriate fi elds. Then press the <Enter> key to save the data. System Date Using the arrow keys, highlight the month, day and year fi elds, and enter...
Page 60 - Serial ATA; options are Disabled and; Serial ATA RAID Enable; Disabled; Native Mode Operation; and; Auto; Channel 2 Master, IDE Channel 3 Master
4-4 X6DH3-G2/X6DHi-G2 User's Manual Serial ATA This setting allows the user to enable or disable the function of Serial ATA. The options are Disabled and Enabled. Serial ATA RAID Enable Select Enable to enable Serial ATA RAID Functions. (*For the Windows OS environment, use the RAID driver if this f...
Page 62 - Selects Ultra DMA Mode. The options are; System Memor y; present in the system.; described in this section.
4-6 X6DH3-G2/X6DHi-G2 User's Manual Transfer Mode Selects the transfer mode. The options are Standard, Fast PIO1, Fast PIO2, Fast PIO3, Fast PIO4, FPIO3 / DMA1 and FPIO4/ DMA 2. Ultra DMA Mode Selects Ultra DMA Mode. The options are Disabled , Mode 0, Mode 1, Mode 2, Mode 3, Mode 4 and Mode 5. Syste...
Page 64 - Cache Video BIOS Area; Write Protect; Cache Extended Memor y
4-8 X6DH3-G2/X6DHi-G2 User's Manual Memory Cache Cache System BIOS Area This setting allows you to designate a reser ve area in the system memor y to be used as a System BIOS buf fer to allow the BIOS to write (cache) its data into this reser ved memor y area. Select Write Protect to enable this fun...
Page 72 - options are On and; Off
4-16 X6DH3-G2/X6DHi-G2 User's Manual Console Redirection Access the submenu to make changes to the following settings. COM Port Address This item allows you to specify which COM port to direct the remote console to: Onboard COM A or Onboard COM B. This setting can also be Disabled . BAUD Rate This i...
Page 73 - threshold. The options are 70; CPU1 Temperature; : If the feature of Auto Fan Control is enabled, the BIOS will; VDD
Chapter 4: BIOS 4-17 Hardware Monitor Logic CPU Temperature Threshold This option allows the user to set a CPU temperature threshold that will activate the alarm system when the CPU temperature reaches this pre-set temperature threshold. The options are 70 o C, 75 o C, 80 o C and 85 o C. Highlight t...
Page 74 - settings are described in this section.; Supervisor Password Is:; password has been entered for the system.; Set Supervisor Password
4-18 X6DH3-G2/X6DHi-G2 User's Manual 4-5 Security Choose Security from the Phoenix BIOS Setup Utility main menu with the arrow keys. You should see the following display. Security setting options are displayed by highlighting the setting using the arrow keys and pressing <Enter>. All Security ...
Page 75 - The other option is; Normal; Password on Boot
Chapter 4: BIOS 4-19 Set User Password When the item "Set User Password" is highlighted, hit the <Enter> key. When prompted, type the user's password in the dialogue box to set or to change the user's password, which allows access to the system at boot-up. Fixed Disk Boot Sector This s...
Page 76 - order and specs of devices in the Item Specifi c Help window.; CDROM Drive; Specifi c Help window.
4-20 X6DH3-G2/X6DHi-G2 User's Manual 4-6 Boot Choose Boot from the Phoenix BIOS Setup Utility main menu with the arrow keys. You should see the following display. Highlighting a setting with a + or - will expand or collapse that entry. See details on how to change the order and specs of boot devices...
Page 77 - changes you may have made.; Load Setup Defaults; BIOS Setup. These are the safest settings to use.; Discard Changes; You will remain in the Setup utility.; Save Changes; in the Setup utility.
Chapter 4: BIOS 4-21 4-7 Exit Choose Exit from the Phoenix BIOS Setup Utility main menu with the arrow keys. You should see the following display. All Exit BIOS settings are described in this section. Exit Saving Changes Highlight this item and hit <Enter> to save any changes you made and to e...
Page 78 - NOTES
Page 85 - Appendix; POST Code Description
Appendix B: BIOS POST Codes B-1 This section lists the POST (Power On Self Test) codes for the PhoenixBIOS. POST codes are divided into two categories: recoverable and terminal. Recoverable POST Errors When a recoverable type of error occurs during POST, the BIOS will display an POST code that descr...
Page 86 - xxxx
B-2 X6DH3-G2/X6DHi-G2 User's Manual POST Code Description 18h 8254 timer initialization 1Ah 8237 DMA controller initialization 1Ch Reset Programmable Interrupt Controller 20h 1-3 -1-1 Test DR AM refresh 22h 1-3 -1-3 Test 8742 Keyboard Controller 24h Set ES segment register to 4 GB 28h Auto size DR A...
Page 91 - Appendix C: Software Installation; Appendix C; better functionality than Parallel ATA.; Introduction to the Intel 6300ESB I/O Controller Hub; ATA Operate Mode
Appendix C: Software Installation C-1 Appendix C Installing Software Drivers and the Windows Operating System C-1 Introduction to the Adaptec Embedded Serial ATA RAID Controller Driver Serial ATA (SATA) Serial ATA(SATA) is a physical storage interface. It uses a single cable with a mini- mum of four...
Page 94 - The Adaptec Embedded Serial ATA with HostRAID Controller Driver; with hardware RAID applications.; Using the Adaptec RAID Confi guration Utility (ARC)
C-4 X6DH3-G2/X6DHi-G2 User's Manual The Adaptec Embedded Serial ATA with HostRAID Controller Driver Adaptec's Embedded Serial ATA RAID with HostRAID controller adds RAID func- tionality to the Serial ATA I/O controller by supporting RAID 0 (Striping) or RAID 1 (Mirroring) to enhance the industry's p...
Page 95 - Managing Arrays; To select this option,
Appendix C: Software Installation C-5 Managing Arrays Select this option to view array properties, and delete arrays. The following sections describe the operations Of "Managing Arrays". To select this option, use the arrow keys and the <enter> key to select "Managing Arrays" f...
Page 97 - Creating Arrays; are shown in gray and cannot be used. See; Note
Appendix C: Software Installation C-7 Creating Arrays Before creating arrays, make sure the disks for the array are connected and installed in your system. Note that disks with no usable space, or disks that are un-initialized are shown in gray and cannot be used. See Initializing Disk Drives . To c...
Page 98 - type and press Enter.
C-8 X6DH3-G2/X6DHi-G2 User's Manual Assigning Array Properties Once you've create a new array, you are ready to assign the proper ties to the ar- ray. *Caution: Once the array is created and its proper ties are assigned, you cannot change the array proper ties using the ACU. You will need to use the...
Page 99 - No Init; If you select Migrate for R AID 0, or Build for R AID 1, you will be asked
Appendix C: Software Installation C-9 2. Under the item "Arrays Label", type in an label and press Enter. (Note: The label shall not be more than 15 characters.) 3. For RAID 0, select the desired stripe size. (Note: Available stripe sizes are 16, 32, and 64 KB-default. It is recommended that...
Page 101 - Adding a Bootable Array; To make an array bootable:; Deleting a Bootable Array; To delete a bootable array:
Appendix C: Software Installation C-11 Adding a Bootable Array To make an array bootable: 1. From the Main menu, select Manage Arrays. 2. From the List of Arrays, select the array you want to make bootable, and press Ctrl+ B. 3. Enter Y to create a bootable array when the following message is displa...
Page 102 - Initializing Disk Drives; Caution; to use the array again.; To initialize drives:
C-12 X6DH3-G2/X6DHi-G2 User's Manual Initializing Disk Drives If an installed disk does not appear in the disk selection list for creating a new array, or if it appears grayed out, you may have to initialize it before you can use it as par t of an array. Drives attached to the controller must be ini...
Page 105 - Rebuilding Arrays; array Rebuild operation, the optimal drive is the source drive.
Appendix C: Software Installation C-15 Rebuilding Arrays Note 1: Rebuilding applies to Fault Tolerant array (RAID 1) only. If an array Build process (or initialization) is interrupted or critical with one member missing, you must perform a Rebuild to get the array to Optimal status. For a critical a...
Page 106 - came with gold trims.; you will not be able to use the controller.
C-16 X6DH3-G2/X6DHi-G2 User's Manual The Adaptec Embedded SAS/SATA with HostRAID Controller Driver (*SAS is for the X6DH3-G2 only.) The onboard Adaptec AIC9140W SAS Controller suppor ts two por ts. Each por t suppor ts up to four SAS /SATA drives. * The SAS Cable (CBL- 097) can only be used with bac...
Page 107 - Viewing Array Properties; To view the proper ties of an existing array:
Appendix C: Software Installation C-17 Managing Arrays Select this option to view array proper ties, and delete arrays. The following sections describe the operations Of "Managing Arrays". To select this option, use the arrow keys and the <enter> key to select "Managing Arrays"...
Page 109 - Assigning Array Properties; To assign proper ties to the new array:; Raid Level
Appendix C: Software Installation C-19 Assigning Array Properties Once you've create a new array, you are ready to assign the proper ties to the ar- ray. *Caution : Once the array is created and its proper ties are assigned, you cannot change the array proper ties using the ACU. You will need to use...
Page 110 - capacity of the source drive.
C-20 X6DH3-G2/X6DHi-G2 User's Manual 4. The ACU allows you to use drives of different sizes in a R AID . However, during a build operation, only the smaller drive can be selected as the source or fi rst drive. 5. When migrating from single volume to R AID 0, migrating from a larger drive to a smaller...
Page 111 - Viewing Array Properties.; Step 4
Appendix C: Software Installation C-21 Initializing Disk Drives If an installed disk does not appear in the disk selection list for creating a new array, or if it appears grayed out, you may have to initialize it before you can use it as part of an array. Drives attached to the controller must be in...
Page 112 - To access the SAS utilities:; Controller Confi guration submenu:
C-22 X6DH3-G2/X6DHi-G2 User's Manual Using the SerialSelect Utility to Confi gure SAS Settings (*SAS is for the X6DH3-G2 only.) The SerialSelect Utility enables you to confi gure SAS disk drive settings. To access the SAS utilities: 1. Turn on your computer and press Ctrl+A when prompted to access the...
Page 113 - : The default setting for each item is listed below:; To Set Controller Confi guration:
Appendix C: Software Installation C-23 4. Use the arrow keys to select an item. Then, press <Enter> and the arrow keys to confi gure the setting for the item selected. 5. To load the default settings, press <F6>. ( Note : The default setting for each item is listed below: Runtime BIOS: En...
Page 114 - To Set Physical Confi guration:; Physical Confi guration submenu as shown below:
C-24 X6DH3-G2/X6DHi-G2 User's Manual To Set Physical Confi guration: 1. Turn on your computer and press Ctrl+A when prompted to access the ARC util- ity. 2. Use the arrow keys to select "SerialSelect Utility" and press <Enter> to access the Physical Confi guration submenu as shown below:...
Page 115 - Using the Disk Utilities; To access the disk utilities:
Appendix C: Software Installation C-25 Using the Disk Utilities The Disk Utilities enable you to format or verify the media of your Serial ATA hard disks. To access the disk utilities: 1. Turn on your computer and press Ctrl+A when prompted to access the ARC utility (as shown in the screen below.) 2...
Page 116 - To Exit Adaptec RAID Confi guration Utility; following screen will appear.
C-26 X6DH3-G2/X6DHi-G2 User's Manual To Exit Adaptec RAID Confi guration Utility 1. Once you have completed R AID array confi gurations, press ESC to exit. The following screen will appear. 2. Press Yes to exit the Utility. (*For more information regarding Adaptec R AID Utility, please refer to Adapte...
Page 118 - The bottom; You can also download a copy of the user's guide from our web site.); C-3 Installing Other Software Programs and Drivers; to the right of these items.
C-28 X6DH3-G2/X6DHi-G2 User's Manual Driver/Tool Installation Display Screen Note : Click the icons showing a hand writing on the paper to view the readme fi les for each item. Click the computer icons to the right of these items to install each item (from top to the bottom) one at a time. After inst...
Page 119 - Supero Doctor III; : The Default User Name and Password are ADMIN.; Supero Doctor III Interface Display Screen-I (Health Information)
Appendix C: Software Installation C-29 Supero Doctor III The Supero Doctor III program is a Web-base management tool that suppor ts remote management capability. It includes Remote and Local Management tools. The local management is called the SD III Client. The Supero Doctor III program included on...
Page 120 - came with your motherboard.
C-30 X6DH3-G2/X6DHi-G2 User's Manual Supero Doctor III Interface Display Screen-II (Remote Control) Notes : 1. SD III Software Revision 1.0 can be downloaded from our Web site at: ftp://ftp.supermicro.com /utility/Supero_ Doctor_III /. You can also download SDIII User 's Guide at: ht tp://w w w.supe...