Supermicro X9DRD-iF - Manuals
Supermicro X9DRD-iF – Manual in PDF format online.
Manuals:
Manual Supermicro X9DRD-iF
Summary
Manual Revision 1.1aRelease Date: November 8, 2013Unless you request and receive written permission from Super Micro Computer, Inc., you may not copy any part of this document.Information in this document is subject to change without notice. Other products and companies referred to herein are tradem...
Preface T h i s m a n u a l i s w r i t t e n f o r s y s t e m i n t e g r a t o r s , P C t e c h n i c i a n s a n d knowledgeable PC users. It provides information for the installation and use of the X9DRD-iF/LF motherboard. About This Motherboard The Super X9DRD-iF/LF motherboard supports dual ...
iv Conventions Used in the Manual Pay special attention to the following symbols for proper system installation and to prevent damage to the system or injury to yourself: Warning: Important information given to ensure proper system installation or to prevent damage to the components Note: Additional...
Preface v Contacting Supermicro Headquarters Address: Super Micro Computer, Inc.980 Rock Ave.San Jose, CA 95131 U.S.A. Tel: +1 (408) 503-8000 Fax: +1 (408) 503-8008 Email: [email protected] (General Information)[email protected] (Technical Support) Web Site: www.supermicro.com Europe Add...
vi X9DRD-iF/LF Motherboard User’s Manual Table of Contents PrefaceChapter 1 Overview 1-1 Overview ......................................................................................................... 1-11-2 Processor and Chipset Overview..............................................................
vii Table of Contents Serial Ports ............................................................................................... 2-19Video Connection ..................................................................................... 2-19Universal Serial Bus (USB) ..................................
X9DRD-iF/LF Motherboard User’s Manual viii 2-9 Onboard LED Indicators ............................................................................... 2-40 GLAN LEDs .............................................................................................. 2-40IPMI Dedicated LAN LEDs ...............
Chapter 1: Overview 1-1 Chapter 1 Overview 1-1 Overview Checklist Congratulations on purchasing your computer motherboard from an acknowledged leader in the industry. Supermicro boards are designed with the utmost attention to detail to provide you with the highest standards in quality and performan...
1-2 X9DRD-iF/LF Motherboard User’s Manual X9DRD-iF Motherboard Image Note : All graphics shown in this manual were based upon the latest PCB revision of the X9DRD-iF available at the time of publishing of the manual. The motherboard you've received may or may not look exactly the same as the graphic...
Chapter 1: Overview 1-3 X9DRD-iF Motherboard Layout Note 1: For the latest CPU/Memory updates, please refer to our website at http://www.supermicro.com/products/motherboard/ for details. Note 2: Changing BMC log-in information is recommended during initial system power-on. The default username is AD...
1-4 X9DRD-iF/LF Motherboard User’s Manual Notes: • See Chapter 2 for detailed information on jumpers, I/O ports and JF1 front panel connections. " " indicates the location of "Pin 1". • Jumpers/LED Indicators not indicated are for testing only. Also, components that are not documente...
Chapter 1: Overview 1-5 X9DRD-iF/LF Jumpers Jumper Description Default Setting JBT1 Clear CMOS See Chapter 2 JI 2 C1/JI 2 C2 SMB to PCI-E Slots Off (Disabled) JPB1 BMC Enabled Pins 1-2 (Enabled) JPG1 VGA Enabled Pins 1-2 (Enabled) JPL1 GLAN1/GLAN2 Enable Pins 1-2 (Enabled) JPME1 Management Engine (M...
1-6 X9DRD-iF/LF Motherboard User’s Manual Warning : To avoid damaging your motherboard and components, please use a power supply that supports a 24-pin, two 4-pin and two 8-pin power connectors. Be sure to connect the 24-pin and the 8-pin power connectors to your power supply for adequate power deli...
Chapter 1: Overview 1-7 Motherboard Features CPU • Dual Intel ® E5-2600(v2) Series Processors (Socket R LGA 2011); each processor supports four full-width Intel QuickPath Interconnect (QPI) links (with support of up to 25.6 GT/s per QPI link and with Data Transfer Rate of up to 8.0 GT/s per directio...
1-8 X9DRD-iF/LF Motherboard User’s Manual I/O De- vices Serial_Link Connections • SATA Ports Two (2) SATA 3.0 Ports (I-SATA0/1)Four (4) SATA 2.0 Ports (I-SATA2~5)(X9DRD-iF)(I-SATA 0/1 only: X9DRD-LF)Four SCU Connections (SCU0~3)(X9DRD-iF) • RAID (Win-dows & Lat-est Linux) RAID 0, 1, 5, 10(RAID 5...
Chapter 1: Overview 1-9 • Power-on mode for AC power recovery • Intel® Intelligent Power Node Manager (NM) (Available when the NMView utility is installed in the system) • Management Engine (ME) PC Health CPU Monitoring Monitoring • Onboard voltage monitors for 1.8V, +3.3V, 3.3VSB, +5V, +5V SB, +12V...
1-10 X9DRD-iF/LF Motherboard User’s Manual System Block Diagram Note: This is a general block diagram and may not exactly represent the features on your motherboard. See the Motherboard Features pages for the actual specifications of each motherboard. X9DRD-iF Block Diagram PROCESSOR 1 (left) #1 DDR...
Chapter 1: Overview 1-11 X9DRD-LF Block Diagram E5-2600(v2) DDR3 DIMM DDR3 DIMM #1 D C #1 DDR3 DIMM DDR3 DIMM #1 A #1 PE3 PE2 A,B A,B C,D A,B C,D PE2 PE2 PE3 PE3 CPU0 LEFT PE2 DMI DMI PET [1~4] PEG0 [0..3] x4 (Lane 1~4) SATA GEN 3 LPC USB USB PET8 P0 P1 B E5-2600(v2) DDR3 DIMM DDR3 DIMM #1 F E #1 DD...
1-12 X9DRD-iF/LF Motherboard User’s Manual 1-2 Processor and Chipset Overview Built upon the functionality and the capability of Intel E5-2600(v2) Series Proces-sors (Socket R LGA 2011) and the C602 chipset, the X9DRD-iF/LF motherboard provides the performance and feature sets required for dual proc...
Chapter 1: Overview 1-13 1-3 Special Features Recovery from AC Power Loss The Basic I/O System (BIOS) provides a setting that determines how the system will respond when AC power is lost and then restored to the system. You can choose for the system to remain powered off (in which case you must pres...
1-14 X9DRD-iF/LF Motherboard User’s Manual 1-5 ACPI Features ACPI stands for Advanced Configuration and Power Interface. The ACPI specifica - tion defines a flexible and abstract hardware interface that provides a standard way to integrate power management features throughout a PC system, including ...
Chapter 1: Overview 1-15 to shield the computer from noise. It is recommended that you also install a power surge protector to help avoid problems caused by power surges. 1-7 Super I/O The Super I/O supports two high-speed, 16550 compatible serial communication ports (UARTs). Each UART includes a 16...
1-16 X9DRD-iF/LF Motherboard User’s Manual 1-9 Overview of the Nuvoton WPCM450 Controller The Nuvoton WPCM450R Controller, a Baseboard Management Controller (BMC), supports 2D/VGA-compatible Graphic Cores with PCI interface, creating multi-media virtualization via Keyboard/Video/Mouse Redirection (K...
Chapter 2: Installation 2-1 Chapter 2 Installation 2-1 Standardized Warning Statements The following statements are industry-standard warnings, provided to warn the user of situations which have the potential for bodily injury. Should you have questions or experience difficulty, contact Supermicro's...
2-2 X9DRD-iF/LF Motherboard User’s Manual Attention Danger d'explosion si la pile n'est pas remplacée correctement. Ne la remplacer que par une pile de type semblable ou équivalent, recommandée par le fabricant. Jeter les piles usagées conformément aux instructions du fabricant.¡Advertencia! Existe ...
Chapter 2: Installation 2-3 Product Disposal Warning! Ultimate disposal of this product should be handled according to all national laws and regulations. 製品の廃棄 この製品を廃棄処分する場合、国の関係する全ての法律・条例に従い処理する必要が あります。 警告 本产品的废弃处理应根据所有国家的法律和规章进行。 警告 本產品的廢棄處理應根據所有國家的法律和規章進行。 Warnung Die Entsorgung dieses Produkts ...
2-4 X9DRD-iF/LF Motherboard User’s Manual 2-2 Static-Sensitive Devices Electrostatic Discharge (ESD) can damage electronic com ponents. To avoid dam-aging your system board, it is important to handle it very carefully. The following measures are generally sufficient to protect your equipment from ES...
Chapter 2: Installation 2-5 OPEN 1st WARNING ! 2-3 Processor and Heatsink Installation Warning : When handling the processor package, avoid placing direct pressure on the label area. Notes: • Always connect the power cord last, and always remove it before adding, re-moving or changing any hardware c...
2-6 X9DRD-iF/LF Motherboard User’s Manual OPEN 1st WARNING ! 2. Press the second load lever labeled 'Close 1st' to release the load plate that covers the CPU socket from its locking position. 3. With the lever labeled 'Close 1st' fully retracted, gently push down on the lever labelled 'Open 1st' to ...
Chapter 2: Installation 2-7 WARNING ! 1. Using your thumb and the index finger, remove the 'WARNING' plastic cap from the socket. 2. Using your thumb and index finger, hold the CPU on its edges. Align the CPU keys, which are semi-circle cutouts, against the socket keys. 3. Once they are aligned, car...
2-8 X9DRD-iF/LF Motherboard User’s Manual OPEN 1st OPEN 1st 4. With the CPU inside the socket, inspect the four corners of the CPU to make sure that the CPU is properly installed. 5. Close the load plate with the CPU inside the socket. Lock the lever labelled 'Close 1st' first, then lock the lever l...
Chapter 2: Installation 2-9 OPEN 1s t Motherboard Screw#1 Screw#2 Installing a Passive CPU Heatsink 1. Do not apply any thermal grease to the heatsink or the CPU die -- the re- quired amount has already been applied. 2. Place the heatsink on top of the CPU so that the four mounting holes are aligned...
2-10 X9DRD-iF/LF Motherboard User’s Manual Removing the Heatsink Warning: We do not recommend that the CPU or the heatsink be removed. However, if you do need to uninstall the heatsink, please follow the instructions below to uninstall the heatsink to prevent damage done to the CPU or the CPU socket...
Chapter 2: Installation 2-11 F1 BMC CTRL LAN CTRL BIOS FP CTRL A1 COM1 1.10 Rev. X9DRD-iF JBT1 LED2 LEDM 1 LED3 JIPMB1 JD 1 JUIDB JPW4 SP1 JSTBY1 JRK1 JPW3 JPW2 JPW1 JBAT1 JL 1 JOH1 JI2C2 JI2C1 JWD1 JPG1 JPB1 JPL1 FAN4 FA N5 FA N6 FA N2 FA N1 FAN8 FAN7 T-SGPIO2 T-SGPIO1 SCU0 I-S AT A2 I-S AT A1 I-S ...
2-12 X9DRD-iF/LF Motherboard User’s Manual Memory Support for the X9DRD-iF/LF Motherboard The X9DRD-iF/LF motherboard supports up to 512 GB of Load Reduced (LRDIMM), 256 GB of Registered (RDIMM) or 64 GB of Unbuffered (UDIMM) ECC/Non-ECC DDR3 800/1066/1333/1600/1866 MHz 240-pin 4-channel memory modu...
Chapter 2: Installation 2-15 Populating LRDIMM (ECC) Memory Modules Intel E5-2600(v2) Series Processor LRDIMM Memory Support Ranks Per DIMM & Data Width Memory Capacity Per DIMM (See the Note Below) Speed (MT/s) and Voltage Validated by Slot per Channel (SPC) and DIMM Per Channel (DPC) 2 Slots P...
2-16 X9DRD-iF/LF Motherboard User’s Manual F1 BMC CTRL LAN CTRL BIOS FP CTRL A1 COM1 1.10 Rev. X9DRD-iF JBT1 LED2 LEDM 1 LED3 JIPMB1 JD 1 JUIDB JPW4 SP1 JSTBY1 JRK1 JPW3 JPW2 JPW1 JBAT1 JL 1 JOH1 JI2C2 JI2C1 JWD1 JPG1 JPB1 JPL1 FAN4 FA N5 FA N6 FA N2 FA N1 FAN8 FAN7 T-SGPIO2 T-SGPIO1 SCU0 I-S AT A2 ...
Chapter 2: Installation 2-17 Installing the Motherboard 1. Install the I/O shield into the chassis. 2. Locate the mounting holes on the motherboard. 3. Locate the matching mounting holes on the chassis. Align the mounting holes on the motherboard against the mounting holes on the chassis. 4. Install...
2-18 X9DRD-iF/LF Motherboard User’s Manual F1 BMC CTRL LAN CTRL BIOS FP CTRL A1 COM1 1.10 Rev. X9DRD-iF JBT1 LED2 LEDM 1 LED3 JIPMB1 JD 1 JUIDB JPW4 SP1 JSTBY1 JRK1 JPW3 JPW2 JPW1 JBAT1 JL 1 JOH1 JI2C2 JI2C1 JWD1 JPG1 JPB1 JPL1 FAN4 FA N5 FA N6 FA N2 FA N1 FAN8 FAN7 T-SGPIO2 T-SGPIO1 SCU0 I-S AT A2 ...
Chapter 2: Installation 2-19 F1 BMC CTRL LAN CTRL BIOS FP CTRL A1 COM1 1.10 Rev. X9DRD-iF JBT1 LED2 LEDM 1 LED3 JIPMB1 JD 1 JUIDB JPW4 SP1 JSTBY1 JRK1 JPW3 JPW2 JPW1 JBAT1 JL 1 JOH1 JI2C2 JI2C1 JWD1 JPG1 JPB1 JPL1 FAN4 FA N5 FA N6 FA N2 FA N1 FAN8 FAN7 T-SGPIO2 T-SGPIO1 SCU0 I-S AT A2 I-S AT A1 I-S ...
2-20 X9DRD-iF/LF Motherboard User’s Manual Note 1: X9DRD-iF has the front-accessible USB 4/5 and USB 8/9. X9DRD-LF only has USB 4/5. Note 2: X9DRD-iF has the backpanel USB 0/1 and USB 2/3. X9DRD-LF only has the backpanel USB 0/1. F1 BMC CTRL LAN CTRL BIOS FP CTRL A1 COM1 1.10 Rev. X9DRD-iF JBT1 LED2...
Chapter 2: Installation 2-21 F1 BMC CTRL LAN CTRL BIOS FP CTRL A1 COM1 1.10 Rev. X9DRD-iF JBT1 LED2 LEDM 1 LED3 JIPMB1 JD 1 JUIDB JPW4 SP1 JSTBY1 JRK1 JPW3 JPW2 JPW1 JBAT1 JL 1 JOH1 JI2C2 JI2C1 JWD1 JPG1 JPB1 JPL1 FAN4 FA N5 FA N6 FA N2 FA N1 FAN8 FAN7 T-SGPIO2 T-SGPIO1 SCU0 I-S AT A2 I-S AT A1 I-S ...
2-22 X9DRD-iF/LF Motherboard User’s Manual F1 BMC CTRL LAN CTRL BIOS FP CTRL A1 COM1 1.10 Rev. X9DRD-iF JBT1 LED2 LEDM 1 LED3 JIPMB1 JD 1 JUIDB JPW4 SP1 JSTBY1 JRK1 JPW3 JPW2 JPW1 JBAT1 JL 1 JOH1 JI2C2 JI2C1 JWD1 JPG1 JPB1 JPL1 FAN4 FA N5 FA N6 FA N2 FA N1 FAN8 FAN7 T-SGPIO2 T-SGPIO1 SCU0 I-S AT A2 ...
Chapter 2: Installation 2-23 F1 BMC CTRL LAN CTRL BIOS FP CTRL A1 COM1 1.10 Rev. X9DRD-iF JBT1 LED2 LEDM 1 LED3 JIPMB1 JD 1 JUIDB JPW4 SP1 JSTBY1 JRK1 JPW3 JPW2 JPW1 JBAT1 JL 1 JOH1 JI2C2 JI2C1 JWD1 JPG1 JPB1 JPL1 FAN4 FA N5 FA N6 FA N2 FA N1 FAN8 FAN7 T-SGPIO2 T-SGPIO1 SCU0 I-S AT A2 I-S AT A1 I-S ...
2-24 X9DRD-iF/LF Motherboard User’s Manual F1 BMC CTRL LAN CTRL BIOS FP CTRL A1 COM1 1.10 Rev. X9DRD-iF JBT1 LED2 LEDM 1 LED3 JIPMB1 JD 1 JUIDB JPW4 SP1 JSTBY1 JRK1 JPW3 JPW2 JPW1 JBAT1 JL 1 JOH1 JI2C2 JI2C1 JWD1 JPG1 JPB1 JPL1 FAN4 FA N5 FA N6 FA N2 FA N1 FAN8 FAN7 T-SGPIO2 T-SGPIO1 SCU0 I-S AT A2 ...
Chapter 2: Installation 2-25 Power Button Blue+ (OH/Fan Fail/ PWR FaiL/UID LED) 1 NIC1 Link LED Reset Button 2 Power Fail LED HDD LED FP PWRLED Reset PWR 3.3 V ID_UID_SW/3/3V Stby Red+ (Blue LED Cathode) Ground Ground 19 20 3.3V X Ground NMI X NIC2 Link LED NIC2 Activity LED NIC1 Activity LED B NIC1...
2-26 X9DRD-iF/LF Motherboard User’s Manual F1 BMC CTRL LAN CTRL BIOS FP CTRL A1 COM1 1.10 Rev. X9DRD-iF JBT1 LED2 LEDM 1 LED3 JIPMB1 JD 1 JUIDB JPW4 SP1 JSTBY1 JRK1 JPW3 JPW2 JPW1 JBAT1 JL 1 JOH1 JI2C2 JI2C1 JWD1 JPG1 JPB1 JPL1 FAN4 FA N5 FA N6 FA N2 FA N1 FAN8 FAN7 T-SGPIO2 T-SGPIO1 SCU0 I-S AT A2 ...
Chapter 2: Installation 2-27 Power Button Blue+ (OH/Fan Fail/ PWR FaiL/UID LED) 1 NIC1 Link LED Reset Button 2 Power Fail LED HDD LED FP PWRLED Reset PWR 3.3 V ID_UID_SW/3/3V Stby Red+ (Blue LED Cathode) Ground Ground 19 20 3.3V X Ground NMI X NIC2 Link LED NIC2 Activity LED NIC1 Activity LED Power ...
2-28 X9DRD-iF/LF Motherboard User’s Manual F1 BMC CTRL LAN CTRL BIOS FP CTRL A1 COM1 1.10 Rev. X9DRD-iF JBT1 LED2 LEDM 1 LED3 JIPMB1 JD 1 JUIDB JPW4 SP1 JSTBY1 JRK1 JPW3 JPW2 JPW1 JBAT1 JL 1 JOH1 JI2C2 JI2C1 JWD1 JPG1 JPB1 JPL1 FAN4 FA N5 FA N6 FA N2 FA N1 FAN8 FAN7 T-SGPIO2 T-SGPIO1 SCU0 I-S AT A2 ...
Chapter 2: Installation 2-29 F1 BMC CTRL LAN CTRL BIOS FP CTRL A1 COM1 1.10 Rev. X9DRD-iF JBT1 LED2 LEDM 1 LED3 JIPMB1 JD 1 JUIDB JPW4 SP1 JSTBY1 JRK1 JPW3 JPW2 JPW1 JBAT1 JL 1 JOH1 JI2C2 JI2C1 JWD1 JPG1 JPB1 JPL1 FAN4 FA N5 FA N6 FA N2 FA N1 FAN8 FAN7 T-SGPIO2 T-SGPIO1 SCU0 I-S AT A2 I-S AT A1 I-S ...
2-30 X9DRD-iF/LF Motherboard User’s Manual F1 BMC CTRL LAN CTRL BIOS FP CTRL A1 COM1 1.10 Rev. X9DRD-iF JBT1 LED2 LEDM 1 LED3 JIPMB1 JD 1 JUIDB JPW4 SP1 JSTBY1 JRK1 JPW3 JPW2 JPW1 JBAT1 JL 1 JOH1 JI2C2 JI2C1 JWD1 JPG1 JPB1 JPL1 FAN4 FA N5 FA N6 FA N2 FA N1 FAN8 FAN7 T-SGPIO2 T-SGPIO1 SCU0 I-S AT A2 ...
Chapter 2: Installation 2-31 F1 BMC CTRL LAN CTRL BIOS FP CTRL A1 COM1 1.10 Rev. X9DRD-iF JBT1 LED2 LEDM 1 LED3 JIPMB1 JD 1 JUIDB JPW4 SP1 JSTBY1 JRK1 JPW3 JPW2 JPW1 JBAT1 JL 1 JOH1 JI2C2 JI2C1 JWD1 JPG1 JPB1 JPL1 FAN4 FA N5 FA N6 FA N2 FA N1 FAN8 FAN7 T-SGPIO2 T-SGPIO1 SCU0 I-S AT A2 I-S AT A1 I-S ...
2-32 X9DRD-iF/LF Motherboard User’s Manual F1 BMC CTRL LAN CTRL BIOS FP CTRL A1 COM1 1.10 Rev. X9DRD-iF JBT1 LED2 LEDM 1 LED3 JIPMB1 JD 1 JUIDB JPW4 SP1 JSTBY1 JRK1 JPW3 JPW2 JPW1 JBAT1 JL 1 JOH1 JI2C2 JI2C1 JWD1 JPG1 JPB1 JPL1 FAN4 FA N5 FA N6 FA N2 FA N1 FAN8 FAN7 T-SGPIO2 T-SGPIO1 SCU0 I-S AT A2 ...
Chapter 2: Installation 2-33 F1 BMC CTRL LAN CTRL BIOS FP CTRL A1 COM1 1.10 Rev. X9DRD-iF JBT1 LED2 LEDM 1 LED3 JIPMB1 JD 1 JUIDB JPW4 SP1 JSTBY1 JRK1 JPW3 JPW2 JPW1 JBAT1 JL 1 JOH1 JI2C2 JI2C1 JWD1 JPG1 JPB1 JPL1 FAN4 FA N5 FA N6 FA N2 FA N1 FAN8 FAN7 T-SGPIO2 T-SGPIO1 SCU0 I-S AT A2 I-S AT A1 I-S ...
2-34 X9DRD-iF/LF Motherboard User’s Manual F1 BMC CTRL LAN CTRL BIOS FP CTRL A1 COM1 1.10 Rev. X9DRD-iF JBT1 LED2 LEDM 1 LED3 JIPMB1 JD 1 JUIDB JPW4 SP1 JSTBY1 JRK1 JPW3 JPW2 JPW1 JBAT1 JL 1 JOH1 JI2C2 JI2C1 JWD1 JPG1 JPB1 JPL1 FAN4 FA N5 FA N6 FA N2 FA N1 FAN8 FAN7 T-SGPIO2 T-SGPIO1 SCU0 I-S AT A2 ...
Chapter 2: Installation 2-35 F1 BMC CTRL LAN CTRL BIOS FP CTRL A1 COM1 1.10 Rev. X9DRD-iF JBT1 LED2 LEDM 1 LED3 JIPMB1 JD 1 JUIDB JPW4 SP1 JSTBY1 JRK1 JPW3 JPW2 JPW1 JBAT1 JL 1 JOH1 JI2C2 JI2C1 JWD1 JPG1 JPB1 JPL1 FAN4 FA N5 FA N6 FA N2 FA N1 FAN8 FAN7 T-SGPIO2 T-SGPIO1 SCU0 I-S AT A2 I-S AT A1 I-S ...
2-36 X9DRD-iF/LF Motherboard User’s Manual F1 BMC CTRL LAN CTRL BIOS FP CTRL A1 COM1 1.10 Rev. X9DRD-iF JBT1 LED2 LEDM 1 LED3 JIPMB1 JD 1 JUIDB JPW4 SP1 JSTBY1 JRK1 JPW3 JPW2 JPW1 JBAT1 JL 1 JOH1 JI2C2 JI2C1 JWD1 JPG1 JPB1 JPL1 FAN4 FA N5 FA N6 FA N2 FA N1 FAN8 FAN7 T-SGPIO2 T-SGPIO1 SCU0 I-S AT A2 ...
Chapter 2: Installation 2-37 F1 BMC CTRL LAN CTRL BIOS FP CTRL A1 COM1 1.10 Rev. X9DRD-iF JBT1 LED2 LEDM 1 LED3 JIPMB1 JD 1 JUIDB JPW4 SP1 JSTBY1 JRK1 JPW3 JPW2 JPW1 JBAT1 JL 1 JOH1 JI2C2 JI2C1 JWD1 JPG1 JPB1 JPL1 FAN4 FA N5 FA N6 FA N2 FA N1 FAN8 FAN7 T-SGPIO2 T-SGPIO1 SCU0 I-S AT A2 I-S AT A1 I-S ...
2-38 X9DRD-iF/LF Motherboard User’s Manual F1 BMC CTRL LAN CTRL BIOS FP CTRL A1 COM1 1.10 Rev. X9DRD-iF JBT1 LED2 LEDM 1 LED3 JIPMB1 JD 1 JUIDB JPW4 SP1 JSTBY1 JRK1 JPW3 JPW2 JPW1 JBAT1 JL 1 JOH1 JI2C2 JI2C1 JWD1 JPG1 JPB1 JPL1 FAN4 FA N5 FA N6 FA N2 FA N1 FAN8 FAN7 T-SGPIO2 T-SGPIO1 SCU0 I-S AT A2 ...
2-40 X9DRD-iF/LF Motherboard User’s Manual F1 BMC CTRL LAN CTRL BIOS FP CTRL A1 COM1 1.10 Rev. X9DRD-iF JBT1 LED2 LEDM 1 LED3 JIPMB1 JD 1 JUIDB JPW4 SP1 JSTBY1 JRK1 JPW3 JPW2 JPW1 JBAT1 JL 1 JOH1 JI2C2 JI2C1 JWD1 JPG1 JPB1 JPL1 FAN4 FA N5 FA N6 FA N2 FA N1 FAN8 FAN7 T-SGPIO2 T-SGPIO1 SCU0 I-S AT A2 ...
Chapter 2: Installation 2-41 F1 BMC CTRL LAN CTRL BIOS FP CTRL A1 COM1 1.10 Rev. X9DRD-iF JBT1 LED2 LEDM 1 LED3 JIPMB1 JD 1 JUIDB JPW4 SP1 JSTBY1 JRK1 JPW3 JPW2 JPW1 JBAT1 JL 1 JOH1 JI2C2 JI2C1 JWD1 JPG1 JPB1 JPL1 FAN4 FA N5 FA N6 FA N2 FA N1 FAN8 FAN7 T-SGPIO2 T-SGPIO1 SCU0 I-S AT A2 I-S AT A1 I-S ...
2-42 X9DRD-iF/LF Motherboard User’s Manual Note 1: X9DRD-LF only has I-SATA0 and I-SATA1. Note 2: For more information on SATA HostRAID configuration, please refer to the Intel SATA HostRAID User's Guide posted on our website @ http://www.supermicro.com.. F1 BMC CTRL LAN CTRL BIOS FP CTRL A1 COM1 1....
3-1 Chapter 3: Troubleshooting Chapter 3 Troubleshooting 3-1 Troubleshooting Procedures Use the following procedures to troubleshoot your system. If you have followed all of the procedures below and still need assistance, refer to the ‘Technical Support Procedures’ and/or ‘Returning Merchandise for ...
3-2 X9DRD-iF/LF Motherboard User’s Manual No Video 1. If the power is on, but you have no video, remove all the add-on cards and cables. 2. Use the speaker to determine if any beep codes exist. Refer to Appendix A for details on beep codes. System Boot Failure If the system does not display POST or ...
3-3 Chapter 3: Troubleshooting Memory Errors When a No-Memory Beep Code is issued by the system, check the following: 1. Make sure that the memory modules are compatible with the system and that the DIMM modules are properly and fully installed. (For memory compatibility, refer to the Memory Compati...
3-4 X9DRD-iF/LF Motherboard User’s Manual within the normal range. Also check the front panel Overheat LED, and make sure that the Overheat LED is not on. 5. Adequate power supply: Make sure that the power supply provides adequate power to the system. Make sure that all power connectors are connecte...
3-5 Chapter 3: Troubleshooting 3-2 Technical Support Procedures Before contacting Technical Support, please take the following steps. Also, please note that as a motherboard manufacturer, Supermicro also sells motherboards through its channels, so it is best to first check with your distributor or r...
3-6 X9DRD-iF/LF Motherboard User’s Manual Proper Battery Disposal Warning: Please handle used batteries carefully. Do not damage the battery in any way; a damaged battery may release hazardous materials into the environment. Do not discard a used battery in the garbage or a public landfill. Please c...
3-7 Chapter 3: Troubleshooting 3-4 Frequently Asked Questions Question: What are the various types of memory that my motherboard can support? Answer: The motherboard supports Registered/Unbuffered ECC DDR3 DIMM or LRDIMM modules. To enhance memory performance, do not mix memory modules of different ...
3-8 X9DRD-iF/LF Motherboard User’s Manual 3-5 Returning Merchandise for Service A receipt or copy of your invoice marked with the date of purchase is required before any warranty service will be rendered. You can obtain service by calling your ven-dor for a Returned Merchandise Authorization (RMA) n...
Chapter 4: AMI BIOS 4-1 Chapter 4 BIOS 4-1 Introduction This chapter describes the AMI BIOS Setup utility for the X9DRD-iF/LF. It also provides the instructions on how to navigate the AMI BIOS Setup utility screens. The AMI ROM BIOS is stored in a Flash EEPROM and can be easily updated. Starting BIO...
4-2 X9DRD-iF/LF Motherboard User’s Manual Note : For AMI UEFI BIOS Recovery, please refer to the UEFI BIOS Recov- ery User Guide posted @ http://www.supermicro.com/support/manuals/. Starting the Setup Utility Normally, the only visible Power-On Self-Test (POST) routine is the memory test. As the mem...
4-4 X9DRD-iF/LF Motherboard User’s Manual 4-3 Advanced Setup Configurations Use the arrow keys to select Advanced Setup and press <Enter> to access the following submenu items. Boot Features Quiet Boot This feature allows the user to select bootup screen display between POST mes-sages and th...
Chapter 4: AMI BIOS 4-5 Interrupt 19 Capture Interrupt 19 is the software interrupt that handles the boot disk function. When this item is set to Enabled, the ROM BIOS of the host adaptors will "capture" Interrupt 19 at bootup and allow the drives that are attached to these host adaptors to ...
4-8 X9DRD-iF/LF Motherboard User’s Manual Intel® Virtualization Technology (Available when supported by the CPU) Select Enabled to support Intel Virtualization Technology, which will allow one platform to run multiple operating systems and applications in independent parti-tions, creating multiple &...
Chapter 4: AMI BIOS 4-9 CPU C6 Report (Available when Power Technology is set to Custom) Select Enabled to allow the BIOS to report the CPU C6 State (ACPI C3) to the operating system. During the CPU C6 State, the power to all cache is turned off. The options are Enabled and Disabled. CPU C7 Report (...
4-10 X9DRD-iF/LF Motherboard User’s Manual Short Duration Power Limit This item displays the time period during which short duration power is main-tained. Chipset Configuration North Bridge This feature allows the user to configure the settings for the Intel North Bridge. Integrated IO Configu...
Chapter 4: AMI BIOS 4-11 CPU1 Slot5 PCI-E 3.0 x8 Link Speed This feature allows the user to set the PCI-Exp bus speed for the slot specified above. The options are Gen1 (Generation 1), Gen2 and Gen3 . IIO 2 PCIe Port Bifurcation Control This submenu configures the following IO PCIe Port Bifurcation ...
4-12 X9DRD-iF/LF Motherboard User’s Manual Mirroring This item displays if memory mirroring is supported by the motherboard. Memory mirroring creates a duplicate copy of the data stored in the memory to enhance data security. Sparing This item displays if memory sparing is supported by the motherboa...
Chapter 4: AMI BIOS 4-13 Demand Scrub Demand Scrubbing is a process that allows the CPU to correct correctable memory errors found on a memory module. When the CPU or I/O issues a demand-read command, and the read data from memory turns out to be a correctable error, the error is corrected and sent ...
4-14 X9DRD-iF/LF Motherboard User’s Manual Legacy USB Support (Available when USB Functions is not Disabled) Select Enabled to support legacy USB devices. Select Auto to disable legacy sup-port if USB devices are not present. Select Disable to have USB devices available for EFI (Extensive Firmware I...
4-16 X9DRD-iF/LF Motherboard User’s Manual PCIe/PCI/PnP Configuration PCI ROM Priority Use this feature to select the Option ROM to boot the system when there are mul-tiple Option ROMs available in the system. The options are EFI Compatible ROM and Legacy ROM . PCI Latency Timer Use this feature t...
Chapter 4: AMI BIOS 4-17 CPU1 Slot 3 PCI-E 3.0 x8 OPROM/CPU1 Slot 4 PCI-E 3.0 x8 OPROM/CPU1 Slot 5 PCI-E 3.0 x8 OPROM/CPU2 Slot 6 PCI-E 3.0 x16 OPROM/CPU2 Slot 7 PCI-E 3.0 x8 OPROM Select Enabled to enable Option ROM support to boot the computer using a network interface from the slots specified abo...
Chapter 4: AMI BIOS 4-19 Console Redirection Settings This feature allows the user to specify how the host computer will exchange data with the client computer, which is the remote computer used by the user. Terminal Type This feature allows the user to select the target terminal emulation type fo...
4-20 X9DRD-iF/LF Motherboard User’s Manual VT-UTF8 Combo Key Support Select Enabled to enable VT-UTF8 Combination Key support for ANSI/VT100 terminals. The options are Enabled and Disabled . Recorder Mode Select Enabled to capture the data displayed on a terminal and send it as text messages to a re...
Chapter 4: AMI BIOS 4-21 High Precision Event Timer Select Enabled to activate the High Precision Event Timer (HPET) that produces periodic interrupts at a much higher frequency than a Real-time Clock (RTC) does in synchronizing multimedia streams, providing smooth playback, reducing the de-pendency...
4-22 X9DRD-iF/LF Motherboard User’s Manual Intel TXT (LT-SX) Configuration Intel TXT (LT-SX) Hardware Support This feature indicates if the following hardware components support the Intel Trusted Execution Technology. CPU : TXT (Trusted Execution Technology) Feature Chipset : TXT (Trusted Executio...
Chapter 4: AMI BIOS 4-23 NIC Configuration Link Speed Use this feature to change the link speed and duplex for the current port. The op-tions are AutoNeg , 10Mbps Half, 10Mbps Full, 100Mbps Half, and 100Mbps full. Blink LEDs This feature allows the user to specify the duration for LEDs to blink. T...
4-24 X9DRD-iF/LF Motherboard User’s Manual 4-4 Event Logs Use this feature to configure Event Log settings. Change SMBIOS Event Log Settings This feature allows the user to configure SMBIOS Event settings. Enabling/Disabling Options SMBIOS Event Log Select Enabled to enable SMBIOS (System Manageme...
4-26 X9DRD-iF/LF Motherboard User’s Manual 4-5 IPMI Use this feature to configure Intelligent Platform Management Interface (IPMI) settings. System Event Log Enabling/Disabling Options SEL Components Select Enabled for all system event logging at bootup. The options are Enabled and Disabled. Erasi...
Chapter 4: AMI BIOS 4-27 Customize EFI Logging Options Log EFI Status Codes Select Enabled to log EFI (Extensible Firmware Interface) Status Codes, Error Codes or Progress Codes. The options are Enabled and Disabled. Note : After making changes on a setting, be sure to reboot the system for the chan...
4-28 X9DRD-iF/LF Motherboard User’s Manual 4-6 Boot This submenu allows the user to configure the following boot settings for the system. CSM Support Select Enabled to support the EFI Compatibility Support Module (CSM), which provides compatibility support for traditional legacy BIOS for system boot...
A-1 Appendix A: BIOS POST Error Codes Appendix A BIOS Error Beep Codes During the POST (Power-On Self-Test) routines, which are performed at each system boot, errors may occur. Non-fatal errors are those which, in most cases, allow the system to continue to boot. The error messages normally appear o...
Appendix B: Software Installation Instructions B-1 Appendix B Software Installation Instructions B-1 Installing Software Programs The Supermicro ftp site contains drivers and utilities for your system at ftp://ftp. supermicro.com . Some of these must be installed, such as the chipset driver. After a...
B-2 X9DRD-iF/LF Motherboard User’s Manual B-2 Configuring SuperDoctor III The SuperDoctor® III program is a web-based management tool that supports remote management capability. It includes Remote and Local Management tools. The local management is called SD III Client. The SuperDoctor III program a...
Appendix B: Software Installation Instructions B-3 SuperDoctor ® III Interface Display Screen (Remote Control) Note: The SuperDoctor III program and User’s Manual can be downloaded from the Supermicro web site at http://www.supermicro.com/products/ac- cessories/software/SuperDoctorIII.cfm . For Linu...
Supermicro Manuals
-
Supermicro X7DBi+
Manual
-
Supermicro MBDX7DA3O
Manual
-
Supermicro H8QM3-2
Manual
-
Supermicro 5016T-TB
Manual
-
Supermicro X8SIL
Manual
-
Supermicro SUPER
Manual
-
Supermicro H8QMI-2
Manual
-
Supermicro SAS-826A
Manual
-
Supermicro X8DTU-6TF+-LR
Manual
-
Supermicro X8DTE
Manual
-
Supermicro X7SPE-HF-D525
Manual
-
Supermicro 6016XT-TF
Manual
-
Supermicro 5014C-T
Manual
-
Supermicro 5015M-NTR
Manual
-
Supermicro 5010E
Manual
-
Supermicro SUPER X5DLR-8G2
Manual
-
Supermicro SC512
Manual
-
Supermicro C2SEA
Manual
-
Supermicro X7SPA-H-D525
Manual
-
Supermicro P3TDDR
Manual