Page 2 - Printed in the United States of America
The information in this User’s Manual has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for any inaccuracies that may be contained in this document, makes no commitment to update or to keep current the information in this manual, or to notify any person...
Page 3 - iii; Preface; About This Manual; Chapter 1: Introduction; the SC113MTQ chassis.; Chapter 2: Server Installation; located throughout the system.; Chapter 4: Standardized Warning Statements
iii Preface Preface About This Manual This manual is written for professional system integrators and PC technicians. It provides information for the installation and use of the SuperServer 1018D-73MTF. Installation and maintenance should be performed by experienced technicians only. The SuperServer ...
Page 4 - UPER; iv; Chapter 5: Advanced Motherboard Setup; modules and cooling fans.; Appendix A: POST Error Beep Codes
S UPER S ERVER 1018D-73MTF User's Manual iv Chapter 5: Advanced Motherboard Setup Chapter 5 provides detailed information on the X10SL7-F motherboard, including the locations and functions of connections, headers and jumpers. Refer to this chapter when adding or removing processors or main memory an...
Page 5 - Notes
Page 6 - Table of Contents; Chapter 1 Introduction; Features; Chapter 2 Server Installation
vi Table of Contents Chapter 1 Introduction 1-1 Overview ......................................................................................................... 1-1 1-2 Motherboard Features ..................................................................................... 1-2 Processors ..........
Page 7 - vii; Chapter 4 Standardized Warning Statements for AC Systems; Cables
vii Table of Contents 3-2 Control Panel Buttons ..................................................................................... 3-1 Reset ............................................................................................................... 3-1 Power .....................................
Page 9 - SATA
Chapter 1 Introduction 1-1 Overview The SuperServer 1018D-73MTF is a high-end server comprised of two main subsystems: the SC113MTQ-330CB 1U server chassis and the X10SL7-F single processor motherboard. Please refer to our web site for information on operating systems that have been certifi ed for u...
Page 10 - Processors; The X10SL7-F supports a single Intel; Memory
1-2 S UPER S ERVER 1018D-73MTF User's Manual 1-2 Motherboard Features At the heart of the SuperServer 1018D-73MTF lies the X10SL7-F, a single proces- sor motherboard based on Intel's C222 chipset. Below are the main features of the X10SL7-F (see Figure 1-1 for a block diagram of the chipset). Proces...
Page 11 - Chapter 1: Introduction; -3 Server Chassis Features; of the main features of the SC113MTQ-330CB chassis.; System Power; sis includes a single 330W high-effi ciency power supply.; Control Panel; Fan speed is controlled via IPMI.
1-3 Chapter 1: Introduction 1-3 Server Chassis Features The SC113MTQ-330CB is a short depth (20") 1U chassis that features eight 2.5" hard drive bays and a high-effi ciency power supply. The following is a general outline of the main features of the SC113MTQ-330CB chassis. System Power When ...
Page 12 - System Block Diagram
1-4 S UPER S ERVER 1018D-73MTF User's Manual Figure 1-1. Intel C222 Chipset: System Block Diagram Note: This is a general block diagram. Please see Chapter 5 for details. Intel DDR3 (CHA) (H3) PCIe3.0_x8 VRM 12.5 SVID LPC I/O NCT6776D PCIe x16 SLOT RJ45 RJ45 DDR3 (CHB) DIMM1 DIMM2(Far) DIMM1 DIMM2(F...
Page 13 - Supermicro; Headquarters
1-5 Chapter 1: Introduction 1-4 Contacting Supermicro Headquarters Address: Super Micro Computer, Inc. 980 Rock Ave. San Jose, CA 95131 U.S.A. Tel: +1 (408) 503-8000 Fax: +1 (408) 503-8008 Email: [email protected] (General Information) [email protected] (Technical Support) Web Site: www....
Page 15 - Chapter 2: Server Installation; Chapter 2; -2 Unpacking the System; fi le a damage claim with the carrier who delivered it.; -3 Preparing for Setup; Choosing a Setup Location
Chapter 2: Server Installation 2-1 Chapter 2 Server Installation 2-1 Overview This chapter provides a quick setup checklist to get your SuperServer 1018D-73MTF up and running. Following these steps in the order given should enable you to have the system operational within a minimum amount of time. T...
Page 16 - -4 Warnings and Precautions; Rack Precautions; before
2-2 S UPER S ERVER 1018D-73MTF Manual • This product is not suitable for use with visual display work place devices acccording to §2 of the the German Ordinance for Work with Visual Display Units. 2-4 Warnings and Precautions Rack Precautions • Ensure that the leveling jacks on the bottom of the rac...
Page 17 - Rack Mounting Considerations; Ambient Operating Temperature
Chapter 2: Server Installation 2-3 Rack Mounting Considerations Ambient Operating Temperature If installed in a closed or multi-unit rack assembly, the ambient operating tempera- ture of the rack environment may be greater than the ambient temperature of the room. Therefore, consideration should be ...
Page 18 - -4 Installing the System into a Rack; lation instructions that came with the rack unit you are using.; Identifying the Sections of the Rack Rails; Figure 2-1. Identifying the Sections of the Rack Rails; do not pick up the server with the front handles. They are de-
2-4 S UPER S ERVER 1018D-73MTF Manual 2-4 Installing the System into a Rack This section provides information on installing the SuperServer 1018D-73MTF into a rack. If the 1018D-73MTF has already been mounted into a rack, you can skip ahead to Sections 2-5 and 2-6. Note: The rails will fi t a rack b...
Page 19 - rail extension to stabilize the chassis within the rack.
Chapter 2: Server Installation 2-5 Figure 2-2. Installing Chassis Rails Inner Rails The SC113MTQ chassis includes a set of inner rails in two sections: inner rails and inner rail extensions. The inner rails are pre-attached and do not interfere with normal use of the chassis if you decide not to use...
Page 20 - Outer Rails; fi ts snugly into the rack.
2-6 S UPER S ERVER 1018D-73MTF Manual Outer Rails Installing the Outer Rails to the Rack (Figures 2-3 and 2-4) 1. Attach the short bracket to the outside of the long bracket. You must align the pins with the slides. Also, both bracket ends must face the same direction. 2. Adjust both the short and l...
Page 21 - Figure 2-4. Installing the Outer Rails to the Rack
Chapter 2: Server Installation 2-7 SCALE 0.380 Figure 2-4. Installing the Outer Rails to the Rack 2 3 3
Page 22 - Figure 2-5. Installing the Server into a Rack; that the outer rails are installed on the rack.
2-8 S UPER S ERVER 1018D-73MTF Manual Figure 2-5. Installing the Server into a Rack Installing the Chassis into a Rack (Figure 2-5) 1. Confi rm that chassis includes the inner rails and rail extensions . Also, confi rm that the outer rails are installed on the rack. 2. Line chassis rails with the fr...
Page 23 - Installing the Server into a Telco Rack; Figure 2-6. Installing the Server into a Telco Rack
Chapter 2: Server Installation 2-9 Installing the Server into a Telco Rack To install the SuperServer 1018D-73MTF into a Telco type rack, use two L-shaped brackets on either side of the chassis (four total). First, determine how far follow the server will extend out the front of the rack. Larger cha...
Page 25 - Chapter 3: System Interface; Chapter 3; -2 Control Panel Buttons; Reset; Use the reset button to reboot the system.; Power; standby power supplied to the system.; UID
Chapter 3: System Interface 3-1 Chapter 3 System Interface 3-1 Overview There are several LEDs on the control panel to keep you constantly informed of the overall status of the system as well as the three buttons described below. 3-2 Control Panel Buttons There are three buttons located on the front...
Page 26 - -3 Control Panel LEDs
3-2 S UPER S ERVER 1018D-73MTF Manual NIC1 Indicates network activity on LAN1 when fl ashing. NIC2 Indicates network activity on LAN2 when fl ashing. HDD Indicates SATA and/or peripheral drive activity when fl ashing. Power Indicates power is being supplied to the system's power supply units. This L...
Page 27 - -4 Hard Drive Carrier LEDs; Each hard drive carrier has two LEDs.
Chapter 3: System Interface 3-3 Overheat/Fan Fail/UID LED When this LED fl ashes it indicates a fan failure. When continuously on (not fl ashing) it indicates an overheat condition, which may be caused by cables obstructing the air fl ow in the system or the ambient room temperature being too warm. ...
Page 29 - Chapter 4: Warning Statements for AC Systems; Chapter 4; -1 About Standardized Warning Statements; Warning Defi nition; 警告の定義
4-1 Chapter 4: Warning Statements for AC Systems Chapter 4 Standardized Warning Statements for AC Systems 4-1 About Standardized Warning Statements The following statements are industry standard warnings, provided to warn the user of situations which have the potential for bodily injury. Should you ...
Page 32 - Installation Instructions; Warnung; 設置手順書; 시스템을 전원에 연결하기 전에 설치 안내를 읽어주십시오.
4-4 S UPER S ERVER 1018D-73MTF User's Manual Installation Instructions Warning! Read the installation instructions before connecting the system to the power source. Warnung Vor dem Anschließen des Systems an die Stromquelle die Installationsanweisungen lesen. ¡Advertencia! Lea las instrucciones de i...
Page 33 - Circuit Breaker; サーキット・ブレーカー
4-5 Chapter 4: Warning Statements for AC Systems Circuit Breaker Warning! This product relies on the building's installation for short-circuit (overcurrent) protection. Ensure that the protective device is rated not greater than: 250 V, 20 A. サーキット・ブレーカー この製品は、短絡(過電流)保護装置がある建物での設置を前提としています。 保護装置の定格が...
Page 34 - Power Disconnection Warning; 警告
4-6 S UPER S ERVER 1018D-73MTF User's Manual Power Disconnection Warning 電源切断の警告 システムコンポーネントの取り付けまたは取り外しのために、 シャーシー内部にアクセス するには、 システムの電源はすべてのソースから切断され、電源コードは電源モジュールから取り 外す必要があります。 警告 在你打开机箱并安装或移除内部器件前,必须将系统完全断电,并移除电源线。 警告 在您打開機殼安裝或移除內部元件前,必須將系統完全斷電,並移除電源線。 Warnung Das System muss von allen Quellen...
Page 35 - ילמשח; زاهجلا; Waarschuwing
4-7 Chapter 4: Warning Statements for AC Systems ¡Advertencia! El sistema debe ser disconnected de todas las fuentes de energía y del cable eléctrico quitado de los módulos de fuente de alimentación antes de tener acceso el interior del chasis para instalar o para quitar componentes de sistema. Atte...
Page 36 - Equipment Installation; 機器の設置
4-8 S UPER S ERVER 1018D-73MTF User's Manual Equipment Installation 機器の設置 トレーニングを受け認定された人だけがこの装置の設置、交換、 またはサービスを許可 されています。 Warning! Only trained and qualifi ed personnel should be allowed to install, replace, or service this equipment. Warnung Das Installieren, Ersetzen oder Bedienen dieser Ausrüstu...
Page 37 - Restricted Area
4-9 Chapter 4: Warning Statements for AC Systems アクセス制限区域 このユニットは、 アクセス制限区域に設置されることを想定しています。 アクセス制限区域は、特別なツール、鍵と錠前、その他のセキュリティの手段を用いての み出入りが可能です。 Warning! This unit is intended for installation in restricted access areas. A restricted access area can be accessed only through the use of a special tool...
Page 38 - Battery Handling; صيصخت; 電池の取り扱い
4-10 S UPER S ERVER 1018D-73MTF User's Manual Battery Handling Warning! There is the danger of explosion if the battery is replaced incorrectly. Replace the battery only with the same or equivalent type recommended by the manufacturer. Dispose of used batteries according to the manufacturer's instru...
Page 40 - Redundant Power Supplies; 冗長電源装置
4-12 S UPER S ERVER 1018D-73MTF User's Manual Warnung Dieses Gerät kann mehr als eine Stromzufuhr haben. Um sicherzustellen, dass der Einheit kein trom zugeführt wird, müssen alle Verbindungen entfernt werden. ¡Advertencia! Puede que esta unidad tenga más de una conexión para fuentes de alimentación...
Page 41 - Backplane Voltage; バックプレーンの電圧
4-13 Chapter 4: Warning Statements for AC Systems Backplane Voltage バックプレーンの電圧 システムの稼働中は危険な電圧または電力が、バックプレーン上にかかっています。 修理する際には注意ください。 警告 当系统正在进行时,背板上有很危险的电压或能量,进行维修时务必小心。 警告 當系統正在進行時,背板上有危險的電壓或能量,進行維修時務必小心。 Warnung Wenn das System in Betrieb ist, treten auf der Rückwandplatine gefährliche Spannungen ...
Page 42 - Comply with Local and National Electrical Codes; 地方および国の電気規格に準拠
4-14 S UPER S ERVER 1018D-73MTF User's Manual Comply with Local and National Electrical Codes Warning! Installation of the equipment must comply with local and national electrical codes. 地方および国の電気規格に準拠 機器の取り付けはその地方および国の電気規格に準拠する必要があります。 Warnung Die Installation der Geräte muss den Sicherheitsstandar...
Page 43 - Product Disposal; Attention; 製品の廃棄
4-15 Chapter 4: Warning Statements for AC Systems Product Disposal Warning! Ultimate disposal of this product should be handled according to all national laws and regulations. יצראה למשחה יקוח םואית ! הרהזא תנקתה םייצראהו םיימוקמה למשחה יקוחל תמאות תויהל תבייח דויצה . ﺕﺍﺪﻌﻤﻟﺍ ﺐﻴﻛﺮﺗ ﺔﻴﺋﺎﺑﺮﻬﻜﻟﺍ ﻠﻟ ﻞﺜﺘ...
Page 44 - Hot Swap Fan Warning; ファン・ホットスワップの警告
4-16 S UPER S ERVER 1018D-73MTF User's Manual Waarschuwing De uiteindelijke verwijdering van dit product dient te geschieden in overeenstemming met alle nationale wetten en reglementen. ¡Advertencia! Al deshacerse por completo de este producto debe seguir todas las leyes y reglamentos nacionales. At...
Page 46 - Power Cable and AC Adapter; 電源コードとACアダプター
4-18 S UPER S ERVER 1018D-73MTF User's Manual Warning! When installing the product, use the provided or designated connection cables, power cables and AC adaptors. Using any other cables and adaptors could cause a malfunction or a fi re. Electrical Appliance and Material Safety Law prohibits the use...
Page 47 - AC; UL
4-19 Chapter 4: Warning Statements for AC Systems Attention Lors de l'installation du produit, utilisez les bables de connection fournis ou désigné. L'utilisation d'autres cables et adaptateurs peut provoquer un dysfonctionnement ou un incendie. Appareils électroménagers et de loi sur la sécurité Ma...
Page 49 - -1 Handling the Motherboard; Precautions
Chapter 5: Advanced Motherboard Setup 5-1 Chapter 5 Advanced Motherboard Setup This chapter covers the steps required to install processors and heatsinks to the X10SL7-F motherboard, connect the data and power cables and install add- on cards. All motherboard jumpers and connections are described an...
Page 50 - -2 Processor and Heatsink Installation; Installing an LGA 1150 Processor
5-2 S UPER S ERVER 1018D-73MTF User's Manual 5-2 Processor and Heatsink Installation Warning: When handling the processor package, avoid placing direct pressure on the label area of the fan. Notes: • Always connect the power cord last and always remove it before adding, re- moving or changing any ha...
Page 52 - Installing a CPU Heatsink
5-4 S UPER S ERVER 1018D-73MTF User's Manual 1. Remove power from the system and unplug the AC power cord from the power supply. 2. Do not apply any thermal grease to the heatsink or the CPU die; the required amount has already been applied. 3. Place the heatsink on top of the CPU so that the four m...
Page 53 - Chapter 5: Advanced Motherboard Setup; panel and the power cables.; Connecting Data Cables
Chapter 5: Advanced Motherboard Setup 5-5 5-3 Connecting Cables Now that the processors are installed, the next step is to connect the cables to the motherboard. These include the data (ribbon) cables for the peripherals and control panel and the power cables. Connecting Data Cables The cables used ...
Page 54 - Ports
5-6 S UPER S ERVER 1018D-73MTF User's Manual Figure 5-2. Front Control Panel Header Pins (JF1) 5-4 I/O Ports The I/O ports are color coded in conformance with the PC 99 specifi cation. See Figure 5-3 below for the colors and locations of the various I/O ports. Figure 5-3. Rear Panel I/O Ports 1 1 1 ...
Page 55 - CAUTION; Exercise extreme care when installing or removing DIMM modules; Memor y Suppor t; Front View
Chapter 5: Advanced Motherboard Setup 5-7 5-5 Installing Memory Note: Check the Supermicro web site for recommended memory modules. CAUTION Exercise extreme care when installing or removing DIMM modules to prevent any possible damage. Installing DIMMs Insert the desired number of DIMMs into the memo...
Page 56 - Memory Population Guidelines; Please follow the table below when populating the X10SL7-F.; speeds is not allowed.; Possible System Memory Allocation & Availability
5-8 S UPER S ERVER 1018D-73MTF User's Manual Memory Population Guidelines Please follow the table below when populating the X10SL7-F. DDR3 Unbuffered ECC (UDIMM) Memory DIMM Slots per Channel DIMMs Populat- ed per Channel DIMM Type POR Speeds Ranks per DIMM (any combination) 2 1 Unbuffered DDR3 1333...
Page 57 - -6 Adding PCI Cards; PCI Expansion Slots; left rear of the system.; PCI Card Installation; evenly on both sides of the card.; PCI Slot/Card Confi gurations; Riser
Chapter 5: Advanced Motherboard Setup 5-9 5-6 Adding PCI Cards PCI Expansion Slots One riser card is used to support a PCI expansion (add-on) card in the system. The SC113MTQ chassis can accommodate one standard size (full height full length) PCI expansion card. When viewed from the chassis front, t...
Page 58 - Details; X10SL7-F Quick Reference; Jumper
5-10 S UPER S ERVER 1018D-73MTF User's Manual Figure 5-5. SUPER X10SL7-F Layout 5-7 Motherboard Details IPMI CODE SAS CODE BIOS LICENSE BAR CODEMAC CODE FA N2 FA N3 FA N1 FA N4 FA NA JBR1 JPL2 JPS1 JPUSB1 JPL1 JWD1 JLED1 JPB1 JPG1 JPME1 JPME2 J19 J18 LE3 LE5 LE4 JPW1 JPW2 J21 JI2C1 JI2C2 J3 L-SAS0 L...
Page 60 - Defi nitions; HDD LED; Power Connectors
5-12 S UPER S ERVER 1018D-73MTF User's Manual 5-8 Connector Defi nitions Processor Power Pin Defi nitions (JPW2/JPW3) Pins Defi nition 1 through 4 Ground 5 through 8 +12V ATX Power 24-pin Connector Pin Defi nitions (JPW1) Pin# Defi nition Pin # Defi nition 13 +3.3V 1 +3.3V 14 -12V 2 +3.3V 15 COM 3 C...
Page 61 - Power Fail LED
Chapter 5: Advanced Motherboard Setup 5-13 NIC1/NIC2 (LAN1/LAN2) The NIC (Network Interface Controller) LED connection for LAN port 1 is located on pins 11 and 12 of JF1, and the LED connection for LAN Port 2 is on pins 9 and 10. Attach NIC LED cables to NIC1 LED and NIC2 LED to display network acti...
Page 62 - Serial Ports
5-14 S UPER S ERVER 1018D-73MTF User's Manual Power Button The Power Button connection is located on pins 1 and 2 of JF1. Momentarily contacting both pins will power on/off the system. This button can also be confi g- ured to function as a suspend button (see BIOS Setup). To turn off the power in th...
Page 65 - Ethernet Ports
Chapter 5: Advanced Motherboard Setup 5-17 Ethernet Ports Two Gigabit Ethernet ports (LAN1/2) are located on the I/O backplane on the motherboard to provide internet con- nections. In addition, a dedicated IPMI LAN port is included located above the USB ports on the backplane to provide KVM support ...
Page 67 - Settings; Explanation of Jumpers; To Clear CMOS
Chapter 5: Advanced Motherboard Setup 5-19 5-9 Jumper Settings Explanation of Jumpers To modify the operation of the mother- board, jumpers can be used to choose between optional settings. Jumpers cre- ate shorts between two pins to change the function of the connector. Pin 1 is identifi ed with a s...
Page 70 - -10 Onboard Indicators; IPMI Dedicated LAN LEDs
5-22 S UPER S ERVER 1018D-73MTF User's Manual 5-10 Onboard Indicators LAN1/LAN2 LEDs The Ethernet ports (located beside the VGA port) have two LEDs. On each Giga- bit LAN port, the yellow LED indicates activity when blinking while the other LED may be green, amber or off to indicate the speed of the...
Page 71 - SAS Heartbeat LED
Chapter 5: Advanced Motherboard Setup 5-23 5-11 SAS/SATA Ports SAS/SATA Port Pin Defi nitions Pin # Defi nition 1 Ground 2 TXP 3 TXN 4 Ground 5 RXN 6 RXP 7 Ground SAS Heartbeat LED Status (LEDS2) Color/State Defi nition Green:Blinking SAS Active Red: Solid On SAS Error SAS Heartbeat LED A S A S H e ...
Page 72 - Figure 5-6. Driver Installation Display Screen; -12 Installing Software; After installing each item, you must
5-24 S UPER S ERVER 1018D-73MTF User's Manual Figure 5-6. Driver Installation Display Screen 5-12 Installing Software The Supermicro ftp site contains drivers and utilities for your system at ftp://ftp. supermicro.com . Some of these must be installed, such as the chipset driver. After accessing the...
Page 73 - SuperDoctor III; fi rst need to uninstall SuperDoctor III.
Chapter 5: Advanced Motherboard Setup 5-25 SuperDoctor III The SuperDoctor® III program is a web-based management tool that supports remote management capability. It includes Remote and Local Management tools. The local management is called SD III Client. The SuperDoctor III program allows you to mo...
Page 74 - Figure 5-9. Installing the Onboard Battery; the Supermicro web site at
5-26 S UPER S ERVER 1018D-73MTF User's Manual 5-13 Onboard Battery Please handle used batteries carefully. Do not damage the battery in any way; a damaged battery may release hazardous materials into the environment. Do not discard a used battery in the garbage or a public landfi ll. Please comply w...
Page 75 - Devices
Chapter 6: Advanced Chassis Setup 6-1 Chapter 6 Advanced Chassis Setup This chapter covers the steps required to install components and perform main- tenance on the SC113MTQ-330CB chassis. For component installation, follow the steps in the order given to eliminate the most common problems encounter...
Page 76 - Panel; connectors. Pull all excess cabling out of the airfl ow path.; Cooling
6-2 S UPER S ERVER 1018D-73MTF User's Manual Figure 6-1. Chassis: Front and Rear Views 6-2 Control Panel The control panel (located on the front of the chassis) must be connected to the JF1 connector on the motherboard to provide you with system status indications. A ribbon cable has bundled these w...
Page 77 - Adding a System Fan; System Fan Failure
Chapter 6: Advanced Chassis Setup 6-3 Adding a System Fan 1. Turn off the power to the system and unplug the power cord. 2. Remove the chassis cover then remove the dummy fan from the fan tray. 3. Place the new fan into the vacant space in the housing while making sure the arrows on the top of the f...
Page 78 - Accessing the Drive Bays; Proceed to the next section for instructions.; Hard Drive Installation; remain in the chassis.
6-4 S UPER S ERVER 1018D-73MTF User's Manual 6-4 Drive Bay Installation/Removal Accessing the Drive Bays Hard Drives: Because of their hotswap capability, you do not need to access the inside of the chassis or power down the system to install or replace hard drives. Proceed to the next section for i...
Page 79 - Figure 6-3: Installing a Hard Drive into a Carrier; Swing the handle fully out and use it to pull the unit straight out.
Chapter 6: Advanced Chassis Setup 6-5 2. Align the drive in the carrier so that the screw holes of both line up. Note that there are holes in the carrier marked “SATA” to aid in correct installation. 3. Secure the drive to the carrier with four screws as illustrated below. 4. Insert the drive carrie...
Page 80 - DVD Drive Installation; and the front bezel from the chassis.
6-6 S UPER S ERVER 1018D-73MTF User's Manual Figure 6-4. Removing a Hard Drive 1 1 1 2 DVD Drive Installation The SC113MTQ chassis may have a DVD-ROM installed (optional). Installing or Replacing a DVD-ROM Drive (Figure 6-5) 1. Power down the system and if necessary, remove the server from the rack ...
Page 81 - Chapter 6: Advanced Chassis Setup
Chapter 6: Advanced Chassis Setup 6-7 Figure 6-5. Installing a DVD-ROM Drive
Page 82 - Supply; Power Supply Failure
6-8 S UPER S ERVER 1018D-73MTF User's Manual 6-5 Power Supply The SuperServer 1018D-73MTF has a single 330 watt power supply, which is auto- switching capable. This enables it to automatically sense and operate with a 100V to 240V input voltage. Power Supply Failure If the power supply unit fails, t...
Page 85 - Starting BIOS Setup Utility; Note; How To Change the Confi guration Data
Chapter 7: BIOS 7-1 Chapter 7 BIOS 7-1 Introduction This chapter describes the AMI BIOS Setup Utility for the X10SL7-F. The ROM BIOS is stored in a Flash EEPROM and can be easily updated. This chapter describes the basic navigation of the AMI BIOS Setup Utility setup screens. Note: For AMI BIOS Reco...
Page 86 - How to Start the Setup Utility; Do not upgrade the BIOS unless your system has a BIOS-related issue.
7-2 S UPER S ERVER 1018D-73MTF User's Manual How to Start the Setup Utility Normally, the only visible Power-On Self-Test (POST) routine is the memory test. As the memory is being tested, press the <Delete> key to enter the main menu of the AMI BIOS Setup Utility. From the main menu, you can a...
Page 87 - System Time/System Date; System Date; Version
Chapter 7: BIOS 7-3 The following Main menu items will display: System Time/System Date Use this option to change the system date and time. Highlight System Date or System Time using the arrow keys. Enter new values through the keyboard. Press the <Tab> key or the arrow keys to move between fi...
Page 88 - -3 Advanced Setup Confi gurations; Boot Feature; ROM display mode set by the system BIOS. The options are
7-4 S UPER S ERVER 1018D-73MTF User's Manual 7-3 Advanced Setup Confi gurations Use the arrow keys to select Boot Setup and press <Enter> to access the submenu items: Warning : Take Caution when changing the Advanced settings. An incorrect value, a very high DRAM frequency, or an incorrect DRA...
Page 89 - Power Confi guration
Chapter 7: BIOS 7-5 Wait For 'F1' If Error This feature forces the system to wait until the 'F1' key is pressed if an error oc- curs. The options are Disabled and Enabled . Interrupt 19 Capture Interrupt 19 is the software interrupt that handles the boot disk function. When this item is set to Enabl...
Page 90 - CPU Confi guration
7-6 S UPER S ERVER 1018D-73MTF User's Manual CPU Confi guration The following CPU information will be displayed: • Type of CPU • CPU Signature • Microcode Patch • Max (Maximum) CPU Speed • Min (Minimum) CPU Speed • CPU Speed • Processor Cores • Intel HT(Hyper-Threading) Technology • Intel VT-x (Vi...
Page 97 - Memory Confi guration; Memory Frequency Limiter
Chapter 7: BIOS 7-13 Memory Confi guration This item displays the information on the memory modules installed on the motherboard. • Memory RC Version • Memory Frequency • Total Memory • Memory Voltage • DIMMA1 • DIMMA2 • DIMMB1 • DIMMB2 • CAS Latency (tCL) • Minimum Delay Time • CAS to RAS (tRODmi...
Page 98 - PCH-IO Confi guration
7-14 S UPER S ERVER 1018D-73MTF User's Manual Memory Scrambler This feature enables or disables memory scrambler support for memory error correction. The settings are Enabled and Disabled. PCH-IO Confi guration This item displays the information for PCH-IO Chip. • Intel PCH Rev ID • USB Confi gura...
Page 99 - SATA Confi guration
Chapter 7: BIOS 7-15 EHCI Hand-Off This item is for Operating Systems that do not support Enhanced Host Controller Interface (EHCI) hand-off. When this item is enabled, EHCI ownership change will be claimed by the EHCI driver. The settings are Enabled and Disabled . XHCI Mode This feature handles th...
Page 102 - ACPI Settings; the 8254 Programmable Interval Timer. The options are
7-18 S UPER S ERVER 1018D-73MTF User's Manual Onboard LAN1/LAN2 Option ROM Select iSCSI to use the iSCSI Option ROM to boot the computer using an iSCSI device installed in a L AN por t specifi ed. Select PXE (Preboot Execution Environ- ment) to boot the computer using a PXE device installed in a L A...
Page 104 - Super IO Confi guration
7-20 S UPER S ERVER 1018D-73MTF User's Manual Pending Operation Use this item to schedule a TPM-related operation to be performed by a security device for TPM support. The options are None , Enable Take Ownership, Disable Take Ownership, and TPM Clear. Note: The computer will reboot to carry out a p...
Page 105 - Serial Port Console Redirection; tions are Enabled and Disabled. The default setting is; Console Redirection Settings; into one or more bytes. The options are
Chapter 7: BIOS 7-21 Serial Port Console Redirection COM1/COM2 Use this feature to enable console redirection for COM1 and COM2 ports. The op- tions are Enabled and Disabled. The default setting is Disabled . Console Redirection Settings This feature allows the user to specify how the host compu...
Page 107 - are; Terminal Type; data when the receiving buffer is empty. The options are
Chapter 7: BIOS 7-23 Console Redirection Settings (for EMS) This feature allows the user to specify how the host computer will exchange data with the client computer, which is the remote computer used by the user. Out-of-Band Management Port The feature selects a serial port used by the Microsoft ...
Page 109 - Logs; Change SMBIOS Event Log Settings; during system boot. The options are
Chapter 7: BIOS 7-25 7-4 Event Logs Change SMBIOS Event Log Settings Enabling/Disabling Options SMBIOS Event Log Change this item to enable or disable all features of the SMBIOS Event Logging during system boot. The options are Enabled and Disabled. Erasing Settings Erase Event Log If No is select...
Page 110 - MECI; This is a numeric value. The default value is; METW; to 99. The default value is; View SMBIOS Event Log; This section displays the contents of the SMBIOS Event Log.
7-26 S UPER S ERVER 1018D-73MTF User's Manual MECI The Multiple Event Count Increment (MECI) counter counts the number of oc- curences a duplicate event must happen before the MECI counter is incremented. This is a numeric value. The default value is 1 . METW The Multiple Event Time Window (METW) de...
Page 111 - The following IPMI information will be displayed:
Chapter 7: BIOS 7-27 7-5 IPMI The following IPMI information will be displayed: • IPMI Firmware Revision • IPMI Status System Event Log This feature is used to change the System Event Log (SEL) confi guration. SEL Components - Change this item to enable or disable all features of System Event Logg...
Page 112 - BMC Network Confi guration; take effect when the system is rebooted. The options are
7-28 S UPER S ERVER 1018D-73MTF User's Manual BMC Network Confi guration LAN Channel 1 : This feature allows the user to confi gure the settings for LAN1 Port. Update IPMI LAN Confi guration This feature allows the BIOS to implement any IP/MAC address changes at the next system boot. If the option...
Page 114 - Delete Boot Option; the systems boots during startup.
7-30 S UPER S ERVER 1018D-73MTF User's Manual Delete Boot Option Use this feature to remove a pre-defi ned boot device from which the system will boot during startup. The settings are [any pre-defi ned boot device] Delete Driver Option This feature allows the user to delete a previously defi ned...
Page 115 - Passwords must be at least 3 and up to 20 characters long.; Administrator Password
Chapter 7: BIOS 7-31 7-7 Security Settings This menu allows the user to confi gure the following security settings for the system. • If the Administrator password is defi ned ONLY - this controls access to the BIOS setup ONLY. • If the User's password is defi ned ONLY - this password will need to be...
Page 116 - Discard Changes and Exit; AMI BIOS Utility Program.
7-32 S UPER S ERVER 1018D-73MTF User's Manual 7-8 Save & Exit Select the Exit tab from the BIOS Setup Utility screen to enter the Exit BIOS Setup screen. Discard Changes and Exit Select this option to quit the BIOS Setup without making any permanent changes to the system confi guration, and rebo...
Page 119 - Fatal errors; BIOS Error Beep Codes; Error Message
Appendix A: POST Error Beep Codes A-1 Appendix A POST Error Beep Codes During the POST (Power-On Self-Test) routines, which are performed each time the system is powered on, errors may occur. Non-fatal errors are those which, in most cases, allow the system to continue with bootup. The error message...