Superior VFST-27VSN-2 - Manual
Superior VFST-27VSN-2 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – IMPORTANT SAFETY INFORMATION; TABLE OF CONTENTS; GENERAL INFORMATION; UNVENTED SEE-THROUGH GAS LOG ROOM HEATER TECHNICAL CHART; Natural; Inventory
- Page 3 – to; COMBUSTION AND VENTILATION AIR; input of all operating appliances in the space.; CODES
- Page 4 – PREINSTALLATION
- Page 5 – Noncombustible Material Requirements with No Mantel Installed; Adjustable canopy not required.; Noncombustible Material Heights and Mantel Location; or
- Page 6 – Consult all local codes.; Figure 7; INSTALLATION
- Page 7 – Figure; Figure 9; Step 3. Assembling the Logs; Figure 9. Handle these; Flame Appearance
- Page 8 – ACCESSORIES; REPLACEMENT PARTS
- Page 9 – TROUBLESHOOTING GUIDE FOR UNVENTED GAS PRODUCTS
- Page 10 – OPERATING INSTRUCTIONS; RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.
- Page 11 – PI; FF; Turn Control Knob to “OFF” Position
- Page 12 – REPLACEMENT PARTS LIST; Description
- Page 16 – LHP
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE.
1
Unvented See-Through Gas Log Room Heaters
P/N 903588 REV. G 12/2007
VFST-27VSN-2
VFST-27VSP-2
MODELS
STANDARD SERIES
FOR USE ONLY WITH DECORATIVE TYPE UNVENTED ROOM
HEATERS.
DO NOT BUILD A WOOD FIRE.
FOR YOUR SAFETY: Do not store or use gasoline
or other flammable vapors or liquids in the vicinity
of this or any other appliance.
FOR YOUR SAFETY: What to do if you smell gas:
• DO NOT light any appliance.
• DO NOT touch any electrical switches.
• DO NOT use any phone in your building.
• Immediately call your gas supplier from a
neighbor’s phone.
Follow your gas suppliers instructions.
• If your gas supplier cannot be reached, call the
fire department.
Installation and service must be performed by a
qualified installer, service agency or the gas sup-
plier.
CAREFULLY REVIEW THE INSTRUCTIONS SUPPLIED WITH
THE DECORATIVE TYPE UNVENTED ROOM HEATER FOR
THE MINIMUM FIREPLACE SIZE REQUIREMENT.
DO NOT INSTALL THE APPLIANCE IN THIS FIREBOX, UN-
LESS THIS FIREBOX MEETS THE MINIMUM DIMENSIONS
REQUIRED FOR THE INSTALLATIONS.
This is an unvented gas-fired heater. It uses air
(oxygen) from the room in which it is installed.
Provisions for adequate combustion and ventila-
tion air must be provided. Refer to Combustion
and Ventilation Air Section, Page 3.
Due to high temperatures, the appliance should be located out
of traffic and away from furniture or draperies.
Do not place clothing or other materials on or near this
appliance.
IMPORTANT: READ THESE INSTALLATION INSTRUCTIONS
CAREFULLY BEFORE INSTALLING OR TRYING TO OPERATE
THIS HEATER.
WARNING: IMPROPER INSTALLATION, ADJUSTMENT, AL-
TERATION, SERVICE OR MAINTENANCE CAN CAUSE IN-
JURY OR PROPERTY DAMAGE. REFER TO THIS MANUAL.
FOR ASSISTANCE OR ADDITIONAL INFORMATION CON-
SULT A QUALIFIED INSTALLER, SERVICE AGENCY OR THE
GAS SUPPLIER.
WARNING: IF THE INFORMATION IN THIS MANUAL
IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLO-
SION MAY RESULT CAUSING PROPERTY DAMAGE,
PERSONAL INJURY OR LOSS OF LIFE.
WARNING: DO NOT BURN WOOD OR OTHER MATERIAL IN
THESE APPLIANCES.
INSTALLATION AND
OPERATING INSTRUCTIONS
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
US
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 2 IMPORTANT SAFETY INFORMATION INSTALLER: PLEASE LEAVE THESE INSTRUC-TIONS WITH THE OWNER. OWNER: PLEASE RETAIN THESE INSTRUC-TION FOR FUTURE REFERENCE. TABLE OF CONTENTS General Information ......................... page 2 Inventory .....................
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 3 The National Fuel Gas Code defines a confinedspace as a space whose volume is less than50 ft 3 per 1,000 BTU/Hr (4.8 m 3 per kw) of the aggregate input rating of all appliances in-stalled in that space and an unconfined spaceas a space whose volume i...
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 4 16" Min. 42" Min. Figure 1 Step 2. Ceiling Clearance: The ceiling must beat least 42" from the top of the heater opening( Figure 1 ). Example:VFST heater 34,000 BTU/Hr Gas appliance #1 35,000 BTU/Hr (water heater) Total = 69,000 BTU/Hr * ...