Summary

Page 2 - IMPORTANT SAFETY INFORMATION; TABLE OF CONTENTS; GENERAL INFORMATION; UNVENTED SEE-THROUGH GAS LOG ROOM HEATER TECHNICAL CHART; Natural; Inventory

NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 2 IMPORTANT SAFETY INFORMATION INSTALLER: PLEASE LEAVE THESE INSTRUC-TIONS WITH THE OWNER. OWNER: PLEASE RETAIN THESE INSTRUC-TION FOR FUTURE REFERENCE. TABLE OF CONTENTS General Information ......................... page 2 Inventory .....................

Page 3 - to; COMBUSTION AND VENTILATION AIR; input of all operating appliances in the space.; CODES

NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 3 The National Fuel Gas Code defines a confinedspace as a space whose volume is less than50 ft 3 per 1,000 BTU/Hr (4.8 m 3 per kw) of the aggregate input rating of all appliances in-stalled in that space and an unconfined spaceas a space whose volume i...

Page 4 - PREINSTALLATION

NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 4 16" Min. 42" Min. Figure 1 Step 2. Ceiling Clearance: The ceiling must beat least 42" from the top of the heater opening( Figure 1 ). Example:VFST heater 34,000 BTU/Hr Gas appliance #1 35,000 BTU/Hr (water heater) Total = 69,000 BTU/Hr * ...