Superior SLDVT-30NM - Manual
Superior SLDVT-30NM – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – TABLE OF CONTENTS; Please read and understand these; WARNING; GENERAL INFORMATION
- Page 3 – 0 - latest edition, or the Canadian Electrical; Table 1
- Page 4 – Table 3; REQUIREMENTS FOR THE COMMON-; Table 2; Table 4
- Page 5 – Figure 3; Typical Locations; HORIZONTAL VENT; When the unit is installed with one; LOCATION; Do not insulate the space between the appli-; COLD CLIMATE INSULATION
- Page 6 – VENT TERMINATION CLEARANCES; These instructions should be used as a; Vertical Vent Termination Clearances; Termination Heights For Vents; Figure 6; Horizontal Vent Termination Clearances; Side Elevation View; Minimum; Figure 4 - Multiple Terminations
- Page 7 – EXTERIOR HORIZONTAL VENT TERMINATION CLEARANCE REQUIREMENTS; Figure 7
- Page 8 – MINIMUM CLEARANCES TO COMBUSTIBLES; When the; Hearth Extension; not be allowed to en-croach the area defined by the appliance front; Table 5
- Page 9 – Figure 12 - Nailing Flanges; Figures; Left Side Front Corner of Fireplace Shown; TYPICAL INSTALLATION SEQUENCE; Figure; a. Millivolt Appliances – Install the; PRE-INSTALLATION STEPS; Removing Glass Panels on
- Page 10 – FIREPLACE AND FRAMING SPECIFICATIONS; Vertical Venting Through the Ceiling:; Frame ceiling opening; - Use a plumb line from the ceiling above the appliance to; Framing; Framing should be; Front View
- Page 11 – Table 6; Proper Sizing of Gas Line; Figure 15 - Route Gas Line; Step 2. ROUTING GAS LINE; mm
- Page 12 – Approved Vent Components
- Page 13 – Note: Convert inches into metric equivalent; Effective Vent Length; Model; Table 7; Figures 25 through; Secure FlexTM pipe may also be used. A Vertical; Figure 5; on; Tables on this page
- Page 15 – ) can be installed in the exact same fashion; Swivel joint; Figure 22 - Roof Framing; Storm
- Page 16 – as shown in; be used in this; VERTICAL VENT FIGURES/TABLES; rate sections of concentric flexible; vent will be required.
- Page 17 – Ceiling; Top Vent - THREE ELBOWS; Figures 29
- Page 19 – tion Guard; INSTALLING HORIZONTAL TERMINATION; Venting Connection and Exterior Wall Recessing; Table 8; See
- Page 20 – HORIZONTAL VENT FIGURES/TABLES; Typical termination shown.; Termination Kit and 6 In. Vent; zontal vent run is needed, then; Under no circumstances may separate sections of con-
- Page 21 – See Table 8 on Page 20 as an aid in venting
- Page 22 – See Table 8 on Page 20 as
- Page 24 – Page; CAUTION; Verify proper operation after servicing.
- Page 25 – If an optional control is to be used, wire it in; After the wiring is complete, replace the; WIRING - OPTIONAL FORCED AIR; Blower Access
- Page 26 – Step 6. CONNECTING GAS LINE
- Page 27 – Never use an open flame to; GLOWING EMBERS AND LOGS; Remove the front glass enclosure panel
- Page 28 – Glowing Embers for several applications, do; Place Volcanic; Bag of Glowing
- Page 29 – Catalog Number for the entire
- Page 30 – SLDVT-40 LOG PLACEMENT; Ember Chunk
- Page 31 – SLDVT-45 LOG PLACEMENT; Left Front Log
- Page 32 – ) by lifting and pulling the
- Page 33 – Main Burner Factory Air Shutter; Burner Air Shutter Adjustment; Locate adjustment rod and adjust air shutter to the standard set-; ting as shown in; Burner Air Shutter Adjustment Procedure
- Page 34 – See Page 5 for Cold Climate Insulation; Combustible Wall Framing
- Page 35 – ) o en el termostato; WARNINGS; ) and if used on the; Figure A
- Page 36 – rigid; INSTALLATION ACCESSORIES; Listed Secure VentTM Components
- Page 38 – this installation assumes responsibility for this conversion.; AVERTISSEMENT; assume les responsabilités liées à la conversion.
- Page 39 – Table 9; Millivolt Appliances; Burner Assembly; ment kit is available, order Catalog Number; and replace the pilot orifice as; ELECTRONIC
MODELS
INSTALLATION INSTRUCTIONS
SLDVT Direct-Vent
Gas Fireplaces
SLDVT-30NM
SLDVT-30PM
SLDVT-35NM
SLDVT-35PM
SLDVT-40NM
SLDVT-40PM
SLDVT-45NM
SLDVT-45PM
MILLIVOLT:
SLDVT-30NE
SLDVT-35NE
SLDVT-40NE
SLDVT-45NE
ELECTRONIC:
P/N 506009-01 Rev. E 06/2011
This manual is one of a set of two supporting this product.
Refer to P/N 506010-01 for Care and Operation Instructions.
Ce manuel est disponible en francais, simplement
en faire la demande. Numéro de la pièce 506223-01.
Report No. 100353019PRT-001
This appliance may be installed in an aftermarket permanently located, manufactured home (USA only) or mobile
home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating
plate. This appliance is not convertible for use with other gases unless a certified kit is used.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
INSTALLATEUR : Laissez cette notice avec l'appareil.
CONSOMMATEUR : Conservez cette notice pour
consultation ultérieure.
AVERTISSEMENT : Assurez-vous de bien suivre les
instructions données dans cette notice pour réduire au
minimum le risque d’incindie ou d’explosion ou pour
éviter tout dommage matériel, toute blessure ou la mort.
WARNING: If the information in these instructions
is not followed exactly, a fire or explosion may
result, causing property damage, personal injury,
or death.
WARNING /AVERTISSEMENT/AVISO
• HOT GLASS WILL CAUSE
BURNS.
• DO NOT TOUCH GLASS
UNTIL COOLED.
• NEVER ALLOW CHILDREN
TO TOUCH GLASS.
• UNE SURFACE VITRÉE CHAUDE
PEUT CAUSER DES BRÛLURES.
• LAISSER REFROIDIR LA SURFACE
VITRÉE AVANT D'Y TOUCHER.
• NE PERMETTEZ JAMAIS À UN ENFANT
DE TOUCHER LA SURFACE VITRÉE.
• EL VIDRIO CALIENTE
CAUSARÁ QUEMADURAS.
• USTED DEBE NUNCA
TOCAR EL VIDRIO CALIENTE.
• LOS NIÑOS DEBEN NUNCA
TOCAR EL VIDRIO.
- Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.
- WHAT TO DO IF YOU SMELL GAS:
• Do not t
ry to light any appliance.
• Do not touch any electrical switch; do not use any
phone in your building.
• Immediately call your gas supplier from a
neighbor’
s phone. Follow the gas supplier
’s
instructions.
• If you cannot reach your gas supplier, call the fire
department.
- Installation and service must be performed by a
qualified installer, service agency or the gas supplier.
- Ne pas entreposer ni utilizer d’essence ni d’autres vapeurs
ou liquides inflammables dans le voisinage de cet appareil
ou de tout autre appareil.
- QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ :
• Ne pas tenter d’allumer d’appareil.
• Ne touchez à aucan interrupteu
r. Ne pas vous servir des
téléphones se trouvant dans le bâtiment où vous trouvez.
• Appelez immédiatement votre fournisseur de gaz depuis
un voisin. Suivez les instructions du fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de gaz,
appelez le service des incindies.
-
L
’installation et l’entretien doivent être assurés par un
installateur ou un service d’entretien qualifié ou par le
fournisseur de gaz.
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
2 SUPERIOR DIRECT-VENT GAS FIREPLACES • MODELS SLDVT-30/35/40/45 • INSTALLATION INSTRUCTIONS TABLE OF CONTENTS Packaging . . . . . . . . . . . . . . . . . . . . . . . . . . 2Introduction . . . . . . . . . . . . . . . . . . . . . . . . 2General Information . . . . . . . . . . . . . . . . . . 2Require...
3 SUPERIOR DIRECT-VENT GAS FIREPLACES • MODELS SLDVT-30/35/40/45 • INSTALLATION INSTRUCTIONS WARNING Improper installation, adjust- ment, alteration, service or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional information consult a qualified install...
4 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Figure 2 - Dexen Electronic Gas Valve Pilot Stage Terminal Pressure-Tap (Inlet) Pilot Gas Outlet Supply Gas Inlet Pressure-Tap (Manifold) Burner Stage Terminal Ground (TP) PILOT OUT VENT LO TH TP TH TP HI IN IN Regulator Mounting Screw Test gaug...