Page 2 - Ster ling Ma te rial Pro cess ing; These op er at ing in struc tions are for*:
Parts & Ser vice: Tele phone: (800) 423-3183 Edi tion: 06/99 b 5 3 6- 3 M S SFC-K 2 Ster ling Ma te rial Pro cess ing 5200 West Clinton Ave. Mil wau kee, WI 53223 Tele phone: (414) 354-0970Fax: (414) 354-6421 www.sterlco.com These op er at ing in struc tions are for*: (*Please fill in per son al...
Page 3 - All rights re served.
Ster ling Ma te rial Pro cess ing re tains all rights to change the in for ma tion in theseop er at ing in struc tions at any time with out no tice. We as sume no li a bil ity for any er rors or di rect or in di rect dam age re sult ing in con -text with these op er at ing in struc tions. Copying, t...
Page 5 - TA BLE OF CON TENTS
TA BLE OF CON TENTS 1. Safety in struc tions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 1.1. Warn ings and sym bols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 1.2. Ex pla na tions and in for ma tion . . . . . . . . . . . . . ....
Page 6 - Safety in struc tions; Safety in struc tions 5
1. Safety in struc tions » These safety in struc tions ap ply to all per sons within the range of ac tion of the equip ment. Please in form all per sons within the range of ac tion of theequip ment of the di rect and in di rect haz ards con nected withthe equip ment. These op er at ing in struc tion...
Page 7 - Safety in struc tions 6
1.1. Warn ings and sym bols The fol low ing warn ings and sym bols are used in these op er at ing in struc tions: » This sym bol in di cates dan ger to life! Fa tal or se ri ous in jury ispos si ble if the cor re spond ing in struc tions, reg u la tions orwarn ings are not ob served. L This sym bol ...
Page 9 - In stal la tion in struc tions; En sure in each case that the per son nel are in formed.; In stal la tion in struc tions 8
2. In stal la tion in struc tions » These in stal la tion in struc tions are in tended for per sons withskills in elec tri cal and me chan i cal ar eas due to their train ing,ex pe ri ence and re ceived in struc tions. Per son nel us ing these in stal la tion in struc tions must be in -structed in t...
Page 10 - In stal la tion in struc tions 9
F In stall the equip ment such that all parts are eas ily ac ces si ble; this fa cil i tates main te nance and re pair work. b 5 3 6- 3 M S SFC-K In stal la tion in struc tions 9
Page 11 - In stal la tion in struc tions 10
2.1. Trans port The unit is de liv ered as a com plete sub-assembly. Trans port the unit on a pal let.Lift the unit only by the wall sup port flange (B) or by the hop per loader (A). Useonly suit able lift ing gear (e.g. hoist ing crane or fork lift). » Ob serve the car ry ing ca pac ity of the lift...
Page 12 - In stal la tion in struc tions 11
2.2. In stal la tion For in stal la tion, the wall sup port flange (A) is used. F In stall the safety fil ter by means of four screws which guar an -tee a car ry ing ca pac ity of at least 50 kg (110.3 lbs.). In stall the safety fil ter in such a way that all com po nents re main freely ac ces si bl...
Page 13 - In stal la tion in struc tions 12
2.3. Com pressed air sup ply For op er a tion of the valve, a com -pressed-air sup ply (1/4“) is needed. Check com pressed air pip ing for cor rect in stal la tion and as sem bly. Check fit tings, length and qual ity ofthe hose con nec tions for agree - ment with re quire ments. The op er at ing pre...
Page 14 - In stal la tion in struc tions 13
2.4. Elec tri cal con nec tion » The elec tri cal con nec tion may only be car ried out by trainedper son nel. The reg u la tions of the lo cal Elec tric ity Board must be ob -served. All work must be car ried out with the unit dis con nected fromvolt age and pres sure sup ply. It is not per mit ted...
Page 15 - In stal la tion in struc tions 14; PE
Con nect the ca ble to the plug of the SFC-K’s clean ing valve. Ob serve the con nec tion di a gram: F Con nect the plug to the clean ing valve of the safety fil ter andfas ten the safety screw. b 5 3 6- 3 M S SFC-K In stal la tion in struc tions 14 A B 24VDC PE Con nec tion di a gram SFC-K A B ter ...
Page 16 - Main te nance 15
3. Main te nance » This chap ter is in tended for per sons with skills in elec tri caland me chan i cal ar eas due to their train ing, ex pe ri ence andre ceived in struc tions. Per son nel us ing the in struc tions in this chap ter must be in -structed of the reg u la tions for the pre ven tion of ...
Page 17 - Main te nance 16
L Dis con nect the equip ment from mains sup ply be fore start ingmain te nance pro ce dures to en sure that it can not be switched on un in ten tion ally. Depressurize all com pressed air pip ing of the equip ment be -fore start ing main te nance work. F Please ob serve the main te nance in ter val...
Page 18 - Main te nance 17
3.1. Main te nance in ter vals Daily: Check warn ing signs on equip ment for good leg i bil ity and com plete ness. Check the oil level in the oiler. Empty the wa ter sep a ra tor. Check op er at ing pres sure of the plant’s sup ply net work (5-6 bar sys tem overpressure). Check waste level in the c...
Page 19 - Main te nance 18
3.2. Cleaning the col lect ing bin L For clean ing of the col lect ing bin, the plant should be switched off. Open the tog gle-type fas ten ers (A). Re move the col lect ing bin (B) from the sup -port. Clean the col lect ing bin (B). Place the col lect ing bin (B) back in the sup -port. Close the to...
Page 21 - Main te nance 20
In stall the new fil ter car tridge on the hop per lid. F Use a new lock nut. Tighten the lock nut with 20 Nm. Mount the lock ing pin. Place the hop per lid with the fil ter car tridge on the hop per loader. Close the tog gle-type fas ten ers. & Pur chase or der num ber fil ter car tridge: ID 85...
Page 23 - Out let flap; Pur chase or der num ber; Main te nance 22
Out let flap Open the tog gle-type fas ten ers (A). Re move the col lect ing bin (B) from the sup port. Re move the old seal ing ring (C) from the noz zle of the ma te rial out let. In stall the new seal ing ring (C). F Ob serve the di rec tion of in stal la tion (D). Place the col lect ing bin (B) ...
Page 24 - or; re place the fil ter cartridge.; Main te nance 23
3.5. Re placing/clean ing the fil ter car tridge of the out let con tainer F The fil ter car tridge can also be re placed/cleaned dur ing op er -a tion. Be cause of ac cu mu la tion of dust, Ster ling rec om -mends that you switch off the safety fil ter. Slide the fil ter car tridge off the noz zle ...
Page 25 - Com pressed air sup ply:; Tech ni cal data 24
4. Tech ni cal data Ver sions: SFC-K 40SFC-K 50 Weight: approx. 10 kg (22 lbs) Com pressed air sup ply: 4-6 bar (72-87 PSI) sys tem overpressure b 5 3 6- 3 M S SFC-K Tech ni cal data 24 9 O O m m 3 5 .4 " 4 0 /5 O m m 1 .6 "/ 2 .0 " 262 mm 10.3" 29O mm 11.4" 4 0 /5 O m m 1 .6 ...
Page 26 - Ap pen dix 25
Page 27 - Ap pen dix 26
5.1. Spare parts list » This spare parts list is in tended to be used only by trainedper son nel. Other per sons are not per mit ted to mod ify or re pair the equip -ment. b 5 3 6- 3 M S SFC-K Ap pen dix 26
Page 28 - Ap pen dix 27
SFC-K 40/50 b 5 3 6- 3 M S SFC-K Ap pen dix 27 16 1 20 19 8 31 28 17 6 18 29 5 7 40 27 46 13 14
Page 29 - Ap pen dix 28
Pos. Orderno. / Designation 1 28622 / valve hous ing 5 28624 / col lect ing bin 6 23093 / out let flap with magnet 7 23098 / seal ing ring 8 13428 / nonreturn valve 13 28623 / cylinder 14 23092 / sealing 16 09646 / seal ing ring 17 28420 / seal ing ring 18 28619 / seal ing ring 19 85612 / fil ter ca...