SPX Marley Sigma Steel - Manual

SPX Marley Sigma Steel

SPX Marley Sigma Steel – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
Page: / 28

Table of Contents:

  • Page 5 – he Sigma Steel
  • Page 6 – DIAMETER FAN; COLUMN; CL; OUT; NOTE; Use this bulletin for preliminary layouts only.; TOP OF; per cell
  • Page 7 – Plan; OVERALL OF B; Section; lb
  • Page 8 – ANCHOR BOLTS; SUMP
  • Page 9 – Dimensions
  • Page 10 – Marley Technical Report
  • Page 11 – control. For greater insight on cold water temperature control,; “Cooling Tower Energy and its Management; Frequency modulation devices work well on induced draft,
  • Page 12 – Marley; Plans. The limiting overall dimensions
  • Page 13 – the life of the tower—and imposes no penalty on the manufacturer.; Typical cooling tower performance curve.
  • Page 14 – peratures up to 120°F. The circulating
  • Page 15 – Fan Deck and Fan Cylinder:; Fan cylinders shall be molded FRP.; Mechanical Equipment:
  • Page 16 – fan is properly positioned within the fan cylinder.
  • Page 17 – formed as part of each fill sheet. Fill; Louver
  • Page 18 – Hot Water Distribution System:; corrugated FRP panels, attached with
  • Page 19 – Cold Water Collection Basin
  • Page 20 – Control Options; Add the following paragraph in
  • Page 21 – Fan Motor Variable Speed Drive:; Add the following paragraph in the
  • Page 22 – Marley Premium VFD System
  • Page 23 – circuit with capability to isolate the VFD; Vibration Limit Switch:
  • Page 24 – Convenience and Safety Options; Add the following to the end of this
  • Page 25 – Oil Level Sight Glass:; Include a cold water collection; Factory Mutual Approval:; Hot Water Basin Covers:; Add the following paragraph to
  • Page 26 – Add the following at the end of this
  • Page 27 – stainless steel for materials of construction in the tower.
Loading the manual

/

Marley Sigma Steel

Cooling Tower

/

Engineering Data & Specifications

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 5 - he Sigma Steel

Marley / Sigma Steel Cooling Tower / 5 only accomplish the specified thermal performance— but which will include normal operation- and mainte- nance-enhancing accessories and features. It will also incorporate those standard materials which testing and experience has proven to provide best results i...

Page 6 - DIAMETER FAN; COLUMN; CL; OUT; NOTE; Use this bulletin for preliminary layouts only.; TOP OF; per cell

Marley / Sigma Steel Cooling Tower / Engineering Data : Schematic 6 Use this data for preliminary layouts only. Obtain current drawing from your Marley sales representative. The UPDATE web-based selection software —available at spxcooling.com—provides Sigma Steel model recommendations based on custo...

Page 7 - Plan; OVERALL OF B; Section; lb

Marley / Sigma Steel Cooling Tower / Engineering Data : Support 7 Plan A SPACES AT 4'-0" = L 6" W OVERALL OF B ASIN SUMP OVERFLOW AIR INLET FACE AIR INLET FACE CASED ENDW ALL F ACE CASED ENDW ALL F ACE PRIMARY SUPPORT BEAM INTERMEDIATE BEAM NOTE 1 Use this bulletin for preliminary layouts on...

Other SPX Models

All SPX Other