SPX 98-1514E - Manual

SPX 98-1514E

SPX 98-1514E – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
Page: / 32

Table of Contents:

  • Page 2 – Contents; Note
  • Page 3 – Preparation; Safety First; WarNiNg; access to the distribution basin or maintenance access doors; Warning
  • Page 4 – Tower Location
  • Page 5 – Hoisting-installation; label is located on the side casing; Receiving and Hoisting
  • Page 6 – Tower installation; Place tower (or bottom module of AV6300 through AV6700) on your; Field Installation Manual; Installation
  • Page 7 – Repeat steps 4 through 7 for any remaining cells.; Cased face or air inlet face suction connection:; Caution
  • Page 8 – Normally, one of the following two inlet arrangements is provided:; Standard distribution basin connections:; There is a circular opening; Motor Wiring; Either of following symbols may be shown on the motor nameplate –; . These symbols represent how the motor is constructed on; When using a starter:; • Set motor overload protection to 110% of motor nameplate amps.
  • Page 9 – When using a; six
  • Page 10 – Mechanical Equipment:
  • Page 12 – Operation
  • Page 13 – must; or
  • Page 14 – Tower Operation; With the fan in full operation, if the heat load increases,; or — in SI units
  • Page 15 – “Cooling Tower Energy and its Management”; Marley Technical
  • Page 16 – its appearance should be a signal to the operator to undertake ice
  • Page 17 – Under extended extreme cold conditions, it may be necessary to op-; not
  • Page 18 – effectively by air control during freezing weather.; Towers must not; If the circulating water system cannot be shut; all; water must be bypassed without; intermittent Wintertime Operation:; Unless some means of freeze prevention is incorporated into your
  • Page 19 – Tower Cleaning, Water Treatment and Blowdown; Maintaining Water Quality:; • An atmosphere surrounding the tower no worse than “moderate indus-
  • Page 20 – Maintenance; Cooling Tower Cleaning:; decontamination. Do NOT attempt any service unless the fan motor; instructions on page 12.; instructions on page 12.
  • Page 21 – results in inadequate mixing.; Belt Tensioning; V-Belt Tension Tester is an alternate method for tensioning
  • Page 22 – Sheave alignment; Bushing Fastener Torque Values
  • Page 23 – Schedule of Tower Maintenance; The purchaser or owner is responsible for providing a safe method
  • Page 24 – Cooling Tower Cleaning
  • Page 25 – Seasonal Shutdown instructions; Fiberglass Components:
  • Page 26 – lubricated before returning motor to service.; Prolonged Shutdown; With the exception of the motor, drive system, and; Periodic maintenance:; You may wish to contract with SPX Cooling for
  • Page 27 – Maintenance Schedule
  • Page 28 – Troubleshooting
  • Page 30 – Additional Information; increased load requirements:; AV Series towers are designed such that; These documents contain important information relating; Field installation
Loading the manual

/

Marley

AV

Cooling Tower

/

User Manual 98-1514E

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Contents; Note

2 Contents Tower Location ....................................................................................... 4 Tower Shipment ...................................................................................... 5 Receiving Tower ...................................................................

Page 3 - Preparation; Safety First; WarNiNg; access to the distribution basin or maintenance access doors; Warning

3 Preparation The Marley AV Series cooling tower purchased for this installation repre-sents the current state of the art in crossflow, induced draft cooling tower design. Thermally and operationally, it is the most efficient cooling tower of its class. These instructions—as well as those offered se...

Page 4 - Tower Location

4 Preparation Those are only some of the safety issues that may arise in the design process. SPX strongly recommends that you consult a safety engineer to be sure that all safety considerations have been addressed. Several options are available that may assist you in addressing some of these personn...