38 TeslaIrvine, CA 92618Phone: (949) 679-8000 Redundant Power UnitUser Guide Powers up to four SMC networking devices Janurary 2005 Pub. # 150200050500A R01
Page 6 - ii
L IMITED W ARRANTY ii WARRANTIES EXCLUSIVE: IF AN SMC PRODUCT DOES NOT OPERATE AS WARRANTED ABOVE, CUSTOMER’S SOLE REMEDY SHALL BE REPAIR OR REPLACEMENT OF THE PRODUCT IN QUESTION, AT SMC’S OPTION. THE FOREGOING WARRANTIES AND REMEDIES ARE EXCLUSIVE AND ARE IN LIEU OF ALL OTHER WARRANTIES OR CONDITI...
Page 7 - iii; OMPLIANCES; Industry Canada - Class B
C OMPLIANCES iii C OMPLIANCES FCC - Class B This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. Th...
Page 8 - iv; EC Conformance Declaration - Class B
C OMPLIANCES iv EC Conformance Declaration - Class B SMC contact for these products in Europe is: SMC Networks Europe,Edificio Conata II, Calle Fructuós Gelabert 6-8, 2 o , 4 a , 08970 - Sant Joan Despí, Barcelona, Spain. This information technology equipment complies with the requirements of the Co...
Page 10 - L’installation et la dépose de ce groupe doivent être
C OMPLIANCES vi France and Peru only This unit cannot be powered from IT † supplies. If your supplies are of IT type, this unit must be powered by 230 V (2P+T) via an isolation transformer ratio 1:1, with the secondary con-nection point labelled Neutral, connected directly to earth (ground). † Impéd...
Page 11 - vii
C OMPLIANCES vii • Vous devez raccorder ce groupe à une sortie mise à la terre (mise à la masse) afin de respecter les normes internationales de sécurité. • Le coupleur d’appareil (le connecteur du groupe et non pas la prise murale) doit respecter une configuration qui permet un branchement sur une ...
Page 12 - viii
C OMPLIANCES viii Bitte unbedingt vor dem Einbauen des RPU die folgenden Sicherheitsanweisungen durchlesen: WARNUNG: Die Installation und der Ausbau des Geräts darf nur durch Fachpersonal erfolgen. • Diese Anleitung ist fr die Benutzung durch Netzwerkadministratoren vorgesehen, die fr die Installati...
Page 13 - ix; Warnings and Cautionary Messages
C OMPLIANCES ix Warnings and Cautionary Messages Warnings (in German) Warning: This product does not contain any serviceable user parts. Warning: Installation and removal of the unit must be carried out by qualified personnel only. Warning: When connecting this device to a power outlet, connect the ...
Page 14 - Environmental Statement; End of Product Life Span; Purpose
x Environmental Statement The manufacturer of this product endeavours to sustain an environmentally-friendly policy throughout the entire production process. This is achieved though the following means:• Adherence to national legislation and regulations on environmental production standards.• Conser...
Page 15 - ABLE
ix T ABLE OF C ONTENTS 1 About the Redundant Power Unit . . . . . . . . . . . . . . . . 1-1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1Features and Benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...
Page 17 - Supports four switch units with 12 VDC supply of up to 150 W.
1-1 C HAPTER 1: A BOUT THE R EDUNDANT P OWER U NIT Overview This Redundant Power Unit (SMCRPU14) can supply 600 Watts of backup power to four switches in the event of an AC loss or failure of an internal power supply. Features and Benefits • Supports four switch units with 12 VDC supply of up to 150...
Page 18 - The RPU will operate under a no-load condition.; Front and Rear Panels; Figure 1-1 Front and Rear Panels; LEDs
1-2 • Short-circuit protection prevents the RPU from being damaged from a short circuit on any output channel. • The RPU will operate under a no-load condition. Front and Rear Panels Four status indicators Link, Activity, Fan, Thermal, and Power indicators are located on the RPU’s front panel. While...
Page 19 - Table 1-1 Port Status LEDs; Table 1-2 System LEDs
1-3 Table 1-1 Port Status LEDs LED (1-4) Condition Status Link Off The port does not have a valid connection to a switch. On Yellow The port has a valid connection to a switch. Flashing Yellow There has been an RPU internal power failure. Activity Off The port is not providing power to the connected...
Page 21 - Installation; The RPU may be placed on a desktop or mounted in a rack.; Selecting a Site; allow the status LEDs to be clearly visible
2-1 C HAPTER 2: I NSTALLING THE R EDUNDANT P OWER U NIT Installation The RPU may be placed on a desktop or mounted in a rack. Caution: DO NOT place the RPU on the floor as the case is not waterproof. It is recommended that this RPU be installed in a network equipment rack. Selecting a Site RPU units...
Page 22 - Equipment Checklist; Package Contents; One AC Supply Power Cord — US, Continental Europe or UK; Optional Rack-Mounting Equipment
2-2 - Make sure that a separate grounded power outlet that provides 100 to 240 VAC, 50-60 Hz, is within 2 m (6.56 feet) of each device and is powered from an independent circuit breaker. As with any equipment, using a filter or surge suppressor is recommended. Equipment Checklist After unpacking the...
Page 23 - Mounting; Rack Mounting
2-3 Mounting RPU units can be mounted in a standard 19-inch equipment rack or on a desktop or shelf. Mounting instructions for each type of site follow. Rack Mounting Before rack mounting the unit, pay particular attention to the following factors: • Temperature: Since the temperature within a rack ...
Page 24 - Bracket Mounting Kit.; Figure 2-1 Attaching the Brackets; If also installing RPUs, mount them in the rack below the other
2-4 To rack-mount devices: 1. Attach the brackets to the device using the screws provided in the Bracket Mounting Kit. Figure 2-1 Attaching the Brackets 2. Mount the device in the rack, using four rack-mounting screws (not provided). Figure 2-2 Installing the RPU in a Rack 3. If also installing RPUs...
Page 25 - Montage
2-5 Montage (Rack Mounting - Ger man) SMCRPU14 RPU-Einheiten können an ein standardmäßiges 19-Zoll Einrichtungsrack, einen Arbeitstisch oder ein Regal montiert werden. Folgend finden Sie die Montageanweisungen für jeden Positionstyp. Rack-Montage Beachten Sie die folgenden Faktoren, bevor Sie die Ra...
Page 26 - Desktop or Shelf Mounting; Attach the four adhesive feet to the bottom of the first RPU unit.; Figure 2-3 Attaching the Adhesive Feet; Connecting Switches to the RPU; To connect switches to the RPU:
2-6 Desktop or Shelf Mounting 1. Attach the four adhesive feet to the bottom of the first RPU unit. Figure 2-3 Attaching the Adhesive Feet 2. Set the device on a flat surface near an AC power source, making sure there are at least five centimeters or two inches of space on all sides for proper air f...
Page 27 - Figure 2-4 Power Receptacle; Connect one end of a DC cord to the redundant power receptacle on
2-7 Figure 2-4 Power Receptacle 2. Connect one end of a DC cord to the redundant power receptacle on the supported switch and the other end to an available receptacle on the RPU. 3. Repeat steps 1 and 2 for connecting up to four supported switches to the RPU. 4. Connect one end of the AC cord to the...
Page 28 - Figure 2-5 Connecting the RPU in a Stack
2-8 Figure 2-5 Connecting the RPU in a Stack Note: For International use, you may need to change the AC line cord. You must use a line cord set that has been approved for the receptacle type in your country. RPU output port Stack RPU input port AC Power Supply No.1 AC Power Supply No.2 RPU Unit 1 0 ...
Page 29 - Diagnosing RPU Indicators; Table A-1 Troubleshooting Chart
A-1 A PPENDIX A T ROUBLESHOOTING Diagnosing RPU Indicators Table A-1 Troubleshooting Chart Symptom Action Power LED is Off • Internal power supply is disconnected.• Check connections between the RPU, the power cord, and the wall outlet. • Contact Technical Support. Link LED is Off • The port does no...
Page 31 - Physical Characteristics
B-1 A PPENDIX B. S PECIFICATIONS Physical Characteristics Ports 4 RPU DC power outlets (IEC socket 216C743-07) LEDs Port: Link, ActivitySystem: Power, Fan, Thermal Weight 5.5 kg (12.1 lbs) Size 44.0 x 32.3 x 4.3 cm (17.34 x 12.6 x 1.69 in.) Temperature Operating: 0 to 45 ° C (32 to 110 ° F) Storage:...
Page 32 - Compliances
B-2 Power Supply Internal, auto-ranging transformer: 100 to 240 VAC, 50 to 60 HzOutput 11.5 VDC Power Consumption 644 W (Maximum) 161 W (Maximum per port) Maximum Current 7.8 A @ 110 VAC 3.5 A @ 240 VAC Overload Protection Ports are shutdown when output exceeds 150 W Power Supply +12 VDCInitial accu...
Page 35 - NDEX
I NDEX - 1 A adhesive feet, attaching 2-6air flow requirements 2-1 B brackets, attaching 2-4 C CE Mark 0-ivcompliances 0-iii EMC B-2safety B-3 contents of package 2-2cooling problems A-2cord sets, international 2-8 D desktop mounting 2-6 E EC conformance 0-ivEMC/safety compliance 0-iiiequipment chec...