Page 2 - Series; How to Order; Applicable Auto Switch; Switch Mounting Bracket Part No.
Angular Style Air GripperToggle Type Series MHT2 Size: 32, 40, 50, 63 F9BW S How to Order Bore size 32 mm 32 Action Auto switch Applicable Auto Switch / Refer to page 12-13-1 for further information on auto switches. Double acting D 2 pcs. 1 pc. S “n” pcs. n Without auto switch (Built-in magnet) Nil...
Page 3 - Effective Gripping Force; Precautions; Warning; Maintenance; Angular Style Air Gripper; MHZ
Effective Gripping Force Precautions Warning Maintenance If a workpiece is to be gripped by using the toggle, make sure to periodically check that the workpiece has not shifted during the acceleration of the movement. If the workpiece is not gripped in a stable manner, it could shift or drop and cre...
Page 4 - Dimensions
MHT2-32D MHT2-40D Dimensions 8-M6 x 1 mounting thread Thread depth 10 (Both sides) Open 28 ° Closed –3 ° 4-M6 x 1 thread depth 10 Mounting thread Finger closing port Rc 1/8 Finger opening port Rc 1/8 4-M6 x 1 thread depth 15 Mounting thread 4-M6 x 1 bottom hole dia. 5.1 Thread for mounting attachmen...
Page 6 - Replacement Parts; Construction
No. q w e r t y u i o !0 Description Side plate Finger Lever Joint Shaft Joint pin Cylinder plate Lever pin Bearing Cylinder Material Aluminum alloy Carbon steel Carbon steel Carbon steel Stainless steel Stainless steel Soft steel Stainless steel Note Hard anodized Black zinc chromated Black zinc ch...
Page 7 - Mounting of Auto Switch
Model Hysteresis (Max.) angle MHT2-32D MHT2-40D MHT2-50D MHT2-63D 3 3 3 3 Bore size (mm) Rail mounting Direct mounting A 9 13 11 13.5 B 6 8.5 11.5 14.5 A 9.5 13.5 11.5 14 B 6.5 9 12 15 A 6.5 10.5 8.5 11 B 3.5 6 9 12 C 8 12 10 12.5 D 5 7.5 10.5 13.5 C 12 16 14 16.5 D 9 11.5 14.5 17.5 C 11 15 13 15.5 ...
Page 8 - ) Detection when Gripping Exterior of Workpiece
Various auto switch applications are possible through different combinations of auto switch quantities and detecting positions. 1) Detection when Gripping Exterior of Workpiece Detection example Detection combinations One auto switch Two auto switches How to determine auto switch installation positi...
Page 9 - ) Detection when Gripping Interior of Workpiece; Auto Switch
Various auto switch applications are possible through different combinations of auto switch quantities and detecting positions. 2) Detection when Gripping Interior of Workpiece Detection example Detection combinations One auto switch Two auto switches How to determine auto switch installation positi...
Page 10 - Safety Instructions; or
Safety Instructions These safety instructions are intended to prevent a hazardous situation and /or equipment damage. These instructions indicate the level of potential hazard by labels of "Caution", "Warning" or "Danger" . To ensure safety, be sure to observe ISO 4414 Note 1...
Page 11 - Common Precautions
1. Confirm the specifications. Products represented in this catalog are designed for use in compressed air appllications only (including vacuum), unless otherwise indicated.Do not use the product outside their design parameters.Please contact SMC when using the products in applications other than co...
Page 12 - Reliable quality of products in the global market; SMC’s quality control system
Quality Assurance Information(ISO 9001, ISO 14001) Reliable quality of products in the global market To enable our customers throughout the world to use our products with even greater confidence, SMC has obtained certification for international standards “ISO 9001” and “ISO 14001”, and created a com...
Page 13 - SMC Product Conforming to Inter
CE Mark SMC Product Conforming to Inter SMC products complying with EN/ISO, CSA/UL standards are supporting The CE mark indicates that machines and components meet essential requirements of all the EC Directives applied.It has been obligatory to apply CE marks indicating conformity with EC Directive...
Page 14 - you to comply with EC directives and CSA/UL standards.; CSA Standards & UL Standards; Mark of compliance; national Standards; SMC Product Conforming to International Standards
http://www.smcworld.com you to comply with EC directives and CSA/UL standards. CSA Standards & UL Standards UL and CSA standards have been applied in North America (U.S.A. and Canada) symbolizing safety of electric products, and are defined to mainly prevent danger from electric shock or fire, r...
Page 15 - SMC’s Global Service Network
America Europe U.S.A. SMC Corporation of America 3011 North Franklin Road Indianapolis, IN 46226, U.S.A.TEL: 317-899-4440 FAX: 317-899-3102 CANADA SMC Pneumatics (Canada) Ltd. 6768 Financial Drive Mississauga, Ontario, L5N 7J6 CanadaTEL: 905-812-0400 FAX: 905-812-8686 MEXICO SMC Corporation (Mexico)...
Page 16 - Europe
Europe FINLAND SMC Pneumatics Finland OY PL72, Tiistinniityntie 4, SF-02231 ESP00, FinlandTEL: 09-8595-80 FAX: 09-8595-8595 NORWAY SMC Pneumatics Norway A/S Vollsveien 13C, Granfoss Næringspark N-1366 LYSAKER, NorwayTEL: 67-12-90-20 FAX: 67-12-90-21 BELGIUM (Distributor) SMC Pneumatics N.V./S.A. Nij...