UNIDIRECTIONAL DYNAMIC MICROPHONES

222

HARTREY AVE.. EVANSTON. IL. 60204 U.S.A.

@

A R E A CODE 3 1 ~ / 8 6 6 - z z o o

.

CABLE: SHUREMICRO

TWX: 910-231-0048

TELEX: 72-4381

GENERAL

DATA

MODELS 545 AND 545s

SHEET

UNIDYNEB Ill

The Model 545 Series UNIDYNEO I l l Microphones are

slender dynamic microphones built to provide wide range

reproduction of music and voice, and have an exceptionally

uniform and effective unidirectional pickup pattern.

i

The microphones are particularly suitbLie for high quality

theater-stage sound systems, recording, cathedrals and

churches, and other critical public address systems such as

those used i n political conventions and legislatures, hotels,

stadiums, and public: auditoriums.

Microphone Features:

Unusually effective cardioid pickup pattern that elim-

inates feedback (annoying loudspeaker "squeals") and

prevents echoing (boominess) that sometimes occurs

i n partially-filled halls. Can also be used closer to loud-

speakers than usual, without creating feedback problems

Response especially effective for announcing, narration,

vocal and instrumental music

Cartridge shock mounted for quiet operation

A strong detachable cable especially selected for good

shielding from "hum" p i c k u p

Dependability and ruggedness under all operating con-

ditions

The Model 545 Series Microphones are dual impedance

for connection to microphone inputs rated at 19 to 300 ohms

or to high-impedance microphone inputs.

ARCHITECTS' SPECIFICATIONS

The microphone shall be the Shure Model 545 (5453) or

equivalent. The microphone shall be a dynamic (moving coil)

type microphone with a frequency response of 50 to 15,000

Hz. The unit shall have a cardioid polar characteristic. The
cancellation at the sides shall be approximately 6 dB, and
the cancellation at the rear shall b e 15 to 20 dB. The micro-
phone shall be a dual-impedance microphone with a rated

impedance of 150 ohms for connection t o microphone inputs

rated at 19 to 300 ohms and "High" for connection to high-

impedance microphone inputs. The microphone output
shall be:

Low Impedance

........................................

-

57 d B

(0 dB

=

1 milliwatt per 10 microbars)

High Impedance

.........................

.

.

.

.

.

.

.

-

55 d B

(0 d B = 1 volt per microbar)

The microphone (Model 545) shall be provided with a

swivel adapter, adjustable through 90" from vertical to
horizontal, and suitable for mounting o n a stand having a

% " - 2 7 thread. I t shall be provided with a detachable 4.6m

(15 ft) three-conductor shielded cable with a four-pin male

audio connector (equivalent to the Amphenol MC4M con-
nector) at the microphone end. The overall dimensions of
the microphone shall be 148 mm (5-13116 in.) i n length and

31.8 mm (1%

in.)

i n diameter.

The microphone (Model 5453) shall b e provided with a

swivel, and a built-in On-Off switch. It shall also be provided
with a detachable 4.6m (15 ft) three-conductor shielded cable
with a four-pin male audio connector (equivalent t o the

Amphenol MC4M connector) at the microphone end. The
overall dimensions of the microphone shall be 122.2 mm

(4-13116 in.) i n height, 31.8 mm (1% in.) i n width and 148 mm

(5-13116 in.) i n depth.

IMPEDANCE SELECTION

Either high- o r low-impedance operation of these micro-

phones is selected by the leads chosen for connection at

the equipment end of the microphone cable. For high

impedance, the RED lead i s the "hot" conductor; the shield

is connected to the amplifier o r chassis ground. For
balanced-line low i m ~ e d a n c e , the BLACK and WHITE leads

are the "hot" conductors; the shield i s connected to the

amplifier o r chassis ground. For unbalanced l o w impedance,

the WHITE lead is the "hot" conductor with the BLACK lead
and shield connected together to the amplifier o r chassis

ground. Any leads not being used for a particular connection

should be insulated at the equipment end of the cable.

The low-impedance connection is recommended where

long cable lengths are required o r under conditions of

severe hum disturbance. The permissible cable length is

practically unlimited, since neither response nor level i s

appreciably affected. For use with high-impedance amplifiers,

the Shure Model A95 Series Line Matching Transformers are

available for coupling a low-impedance line to the amplifier
input. The Model A95 Series transformers permit coupling a

19-300 ohm microphone line to a high-impedance input.

C o p y r i g h t 1978. Shure Brothers Inc.

27A443 ( R C )

( O V E R )

Important: Shure Microphone Cables are selected after ex-

haustive tests to insure superior performance i n microphones

because of low capacities, superior shielding properties and

unusually long life under severe use.

Cables with plastic insulation should not be subjected to

excessive soldering-iron heat. Carefully clean and tin the

conductors and the connections to which the conductors

are t o be soldered. The soldering operation can then be

done with a minimum of heat, thereby avoiding any pos-

sibility of damage t o the cable.

U.S.

Patents 3,132,713, 3,240,883 and D190,864

Printed i n

U.S.A.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Was this manual helpful?

Helpful for 4 of 4 readers

About this manual

Brand
Shure
Model
545
Document type
Manual
Language(s)
English
Pages
2
File size
932.5 KB
Format
PDF

Ask a question

Up to 3 photos. Max 5 MB each. Formats: JPG, JPEG, PNG, WebP.