Page 2 - Revision history; Revision
Revision history Copyright © 2008 Seagate Technology LLC. All rights reserved. Printed in U.S.A.Publication number: 100441950, Rev. A May 2008Seagate, Seagate Technology and the Wave logo are registered trademarks of Seagate Technology LLC in the United States and/or other countries. Lyrion Series, ...
Page 3 - Contents
Lyrion CE-ATA Product Manual, Rev. A i Contents 1.0 Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1.1 Disclaimer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....
Page 4 - ii
Page 5 - iii; List of Figures
Lyrion CE-ATA Product Manual, Rev. A iii List of Figures Figure 1. Lyrion Series (CE-ATA interface) disc drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Figure 2. Typical 3.3V startup and operation current profile . . . . . . . . . . . . . . . . . . . . . . . . ...
Page 6 - iv
Page 7 - Introduction; Lyrion
Lyrion CE-ATA Product Manual, Rev. A 1 1.0 Introduction This manual describes the functional, mechanical and interface specifications for the following Seagate ® Lyrion ® Series CE-ATA drives: • ST760211CA-60GB, ST730212CA-30GB disc drives with a CE-ATA interface. These drives provide the following ...
Page 8 - Disclaimer; Seagate Technology LLC; Drive care
2 Lyrion CE-ATA Product Manual, Rev. A 1.1 Disclaimer Seagate Technology LLC makes no warranties whatsoever, including any warranty of merchantability, non- infringement, fitness for any particular purpose, or any warranty otherwise arising out of any proposal, specification or sample. Seagate may n...
Page 9 - Drive specifications; the drive; Overview; definition, see the appropriate section of this manual.; Specifications; Drive specification
Lyrion CE-ATA Product Manual, Rev. A 3 2.0 Drive specifications Unless otherwise noted, all specifications are measured under ambient conditions, at 25°C, and nominal power. For convenience, the phrases the drive and this drive are used throughout this manual to indicate ST760211CA and ST730212CA mo...
Page 11 - Formatted capacity; LBA mode addressing; where; Default logical geometry
Lyrion CE-ATA Product Manual, Rev. A 5 2.2 Formatted capacity LBA mode addressing When addressing these drives in LBA mode, all blocks (sectors) are consecutively numbered from 0 to n–1, where n is the number of guaranteed sectors as defined above . 2.3 Default logical geometry Model Formatted capac...
Page 12 - Technology
6 Lyrion CE-ATA Product Manual, Rev. A 2.4 Recording and interface technology 2.5 Physical characteristics 2.6 Time to ready Technology Specification Interface CE-ATA Recording method Perpendicular Magnetic Recording Recording density BPI (bits/inch average) 1,025,000 Track density TPI (tracks/inch ...
Page 13 - Power specifications
Lyrion CE-ATA Product Manual, Rev. A 7 2.7 Power specifications The drive receives DC power (+3.3V) through the ZIF connector (CE-ATA interface). 2.7.1 Power consumption Power requirements for the drives are listed in the table on page 8. Typical power measurements are based on an average of drives ...
Page 14 - Typical current profile; Typical 3.3V startup and operation current profile; DC power; Power Consumption at 3.3V; Read; Standby
8 Lyrion CE-ATA Product Manual, Rev. A * Maximum is the average of the peak value in 10 msec window 2.7.1.1 Typical current profile Figure 2. Typical 3.3V startup and operation current profile Table 2: DC power Power Consumption at 3.3V Average (W) Startup (max*) 1.15 Read 1.19 Write 1.09 Performanc...
Page 15 - Conducted noise; injected noise at up to 20 MHz.; Voltage tolerance
Lyrion CE-ATA Product Manual, Rev. A 9 2.7.2 Conducted noise Input noise ripple is measured at the host system power supply across an equivalent 15-ohm resistive load on the +3.3 volt line. Using 3.3-volt power, the drive is expected to operate with a maximum of 70 mV peak-to-peak square-wave inject...
Page 17 - Environmental specifications
Lyrion CE-ATA Product Manual, Rev. A 11 2.8 Environmental specifications 2.8.1 Ambient temperature Ambient temperature is defined as the temperature of the environment immediately surrounding the drive. Actual drive case temperature should not exceed 70°C (158°F) within the operating ambient conditi...
Page 18 - Shock; Drive axis definition for Lyrion Series drives; Operating shock
12 Lyrion CE-ATA Product Manual, Rev. A 2.8.5 Shock All shock measurements in this section are carried out at drive level. For all linear shock test, operating or nonoperating, the input shock level is measured at the frame of the drive at the specific location as indicated in Figure 3 below. Figure...
Page 19 - Gs RMS. The drive operates without a hard error while being; Nonoperating sweep sine vibration; Hz to 10 Hz
Lyrion CE-ATA Product Manual, Rev. A 13 2.8.6.1 Operating sweep sine vibration The following lists the maximum operating sweep sine vibration levels that the drive may experience while meeting the performance standards specified. It consists of a forward and backward sweep from 10 Hz to 500 Hz to 10...
Page 21 - Drive level acoustics
Lyrion CE-ATA Product Manual, Rev. A 15 2.9 Acoustics Drive acoustics are measured as overall A-weighted acoustic sound power levels (no pure tones). Discrete tone penalties are added to the A-weighted sound power (LW) with the following formula only when determin-ing compliance: LWt(spec) == LW + 0...
Page 22 - Reliability; Measurement type; Nonrecoverable read errors
16 Lyrion CE-ATA Product Manual, Rev. A 2.11 Reliability Measurement type Specification Nonrecoverable read errors 1 per 10 14 bits read, max. Load/Unload (LUL) cycles 300,000 software-controlled 20,000 power loss Power On Hours (POH) per year 500 hours Warranty Per agreement
Page 23 - Agency certification; Safety certification; Lyrion Series
Lyrion CE-ATA Product Manual, Rev. A 17 2.12 Agency certification 2.12.1 Safety certification The drives are recognized in accordance with UL60950-1, CAN/CSA-C22.2 No.60950-1, EN60950 and IEC 60950. 2.12.2 Electromagnetic compatibility Hard drives that display the CE mark comply with the European Un...
Page 24 - 表示该部件(于同类物品程度上)所含的危险和有毒物质低于中国
18 Lyrion CE-ATA Product Manual, Rev. A 2.12.4 China Restriction of Hazardous Substances (RoHS) Directive This product has an Environmental Protection Use Period (EPUP) of 20 years. The following table contains information mandated by China's "Marking Requirements for Control of Pollution Caused...
Page 25 - . This booklet is available from the Super-
Lyrion CE-ATA Product Manual, Rev. A 19 If necessary, you should consult your dealer or an experienced radio/television technician for additional sug-gestions. You may find helpful the following booklet prepared by the Federal Communications Commission: How to Identify and Resolve Radio-Television I...
Page 27 - Configuring and mounting the drive; Handling and static discharge precautions; Lyrion Series breather hole location
Lyrion CE-ATA Product Manual, Rev. A 21 3.0 Configuring and mounting the drive This section contains the specifications and instructions for configuring and mounting the drive. 3.1 Handling and static discharge precautions After unpacking, and before installation, the drive may be exposed to potenti...
Page 28 - immediately after operation.
22 Lyrion CE-ATA Product Manual, Rev. A • Do not remove the factory-installed labels from the drive or cover them with additional labels. Removal voids the warranty. Some factory-installed labels contain information needed to service the drive. Other labels are used to seal out dirt and contaminatio...
Page 29 - Drive installation; See Figure 7 for drive mechanical dimensions.
Lyrion CE-ATA Product Manual, Rev. A 23 3.2 Drive installation See Figure 7 for drive mechanical dimensions. Follow these installation precautions when inserting the drive:• Follow instructions for the installation of data storage devices, provided with your device’s user manual.• Do not obstruct th...
Page 30 - Lyrion Series FPC dimensions; Mounting considerations; where the mounting material can rest for mounting.
24 Lyrion CE-ATA Product Manual, Rev. A Figure 8. Lyrion Series FPC dimensions 3.3 Mounting considerations • Use an elastic mounting material to protect drives so as to ensure that more shock can be absorbed.• There are guides along the side for mounting. Refer to figure on areas (refer to Figure 9,...
Page 31 - Interface description; Interface signals and connector pins; Pin number
Lyrion CE-ATA Product Manual, Rev. A 25 4.0 Interface description The drives use the CE-ATA interface. 4.1 Interface signals and connector pins The following table summarizes the signals on the 18-way ZIF CE-ATA interface connector. Table 8: 18-way ZIF (CE-ATA interface) connector signals Pin number...
Page 32 - Supported command set and features; MMC command set
26 Lyrion CE-ATA Product Manual, Rev. A 4.2 Supported command set and features This section describes the MMC level commands supported by the drive followed the supported reduced ATA command set and a description of the supported Status and Control Registers (SCR). 4.2.1 MMC command set The followin...
Page 33 - Word; Drive serial number
Lyrion CE-ATA Product Manual, Rev. A 27 Identify Device command The Identify Device command returns a single block of data (512 bytes or 256 words) to the host, the relevant contents per the CE-ATA specification of which are as shown in the following table Table 11: Identify Device commands Word Des...
Page 34 - The detailed description of each registers is as follows:; Status and Control Registers
28 Lyrion CE-ATA Product Manual, Rev. A 4.2.3 Status and Control Registers The Status and Control Registers (SCR) start at MMC register address 80h and can be accessed only by using CMD60 (RW_MULTIPLE_REGISTER) to read or write to them. The following SCR have been defined (RO = The register may be r...
Page 35 - Seagate Technology support services; Internet; mySeagate; Seagate Service Centers; Presales Support; SeaTDD
Lyrion CE-ATA Product Manual, Rev. A 29 5.0 Seagate Technology support services Internet For information regarding Seagate products and services, visit www.seagate.com . Worldwide support is available 24 hours daily by email for your questions. Presales Support: [email protected] Technical Suppor...
Page 36 - Direct dial; and Mexico
30 Lyrion CE-ATA Product Manual, Rev. A Customer Service Operations Warranty Service Seagate offers worldwide customer support for Seagate products. Seagate distributors, OEMs and other direct customers should contact their Seagate Customer Service Operations (CSO) representative for warranty-relate...
Page 37 - Index
Lyrion CE-ATA Product Manual, Rev. A 31 Index A acoustics 15 Active mode 10 agency certification (regulatory) 17 altitude 11 ambient conditions 3 ambient temperature 11 areal density 1 , 6 ATA command set 26 ATA-standard commands 26 Australian C-Tick 17 B BPI 6 buffer 1 , 6 C cache 1 , 6 case temper...