Page 2 - WELCOME; must be reported within 48 hours
Page 2 WELCOME Thank you for purchasing this Schweigen IN appliance.To achieve the optimal performance from your appliance, and to avoid the risk of accident or damage, it is essential to read this manual before installation and first time use.This guide contains important information on the use and...
Page 3 - INDEX
Page 3 INDEX Important safety information ................................................................................................................ 4 Description ......................................................................................................................................
Page 4 - IMPORTANT SAFETY INFORMATION
Page 4 IMPORTANT SAFETY INFORMATION Please read the instructions carefully. Only then will you be able to operate your appliance safely and correctly. Retain the instruction manual for future use or for subsequent owners. Check the appliance for damage after unpacking it. Do not connect or install t...
Page 7 - DESCRIPTION
Page 7 1. Connect the female plug to the Isodrive motor system 2. Male Plug (Main Power 240V)3. 200mm Outlet/s4. Remote5. Filter 6. Cover Panel with LED lights built-in7. Control Module, supplied with main unit onlyNOTE: Filter and light quantity may vary from model to model. *IMPORTANT: The electro...
Page 8 - MOUNTING LAWS AND REGULATIONS; INSTALLATION; MATCH THE RANGEHOOD SIZE TO YOUR COOKTOP
Page 8 MOUNTING LAWS AND REGULATIONS Minimum and maximum heights (cooktop-to-canopy) are legally required. This rangehood is intended for indoor kitchen use. Type of Cooktop Min. Height Optimal Recommended Max. Height* Electric 1200mm 1500mm 1 x Isodrive © 1600: 1800mm; 2 x Isodrive © 1600: 1800mm t...
Page 10 - motor to the rangehood should; SYSTEM OVERVIEW GUIDE FOR CC-SURF2S AND CC-INARTS
Page 10 INSTALLATION DangerAll electrical wiring from the motor to the rangehood should be kept inside the roof space. SYSTEM OVERVIEW GUIDE FOR CC-SURF2S AND CC-INARTS 1. Isodrive Motor/s2. Roof Seal Kit (Dektite)*3. Support Straps*4. Attach Flexi Duct to Bell-Mouth Adaptor using cable tie or ring ...
Page 14 - Twin motor installation
Page 14 INSTALLATION MOTOR SYSTEM OVERVIEW GUIDE FOR CC-PARA4S, CC-PARA4W, CC-PARA3S, CC-PARA3W, CC-PARA2S, CC-PARA2W 1. Isodrive Motor/s2. Roof Seal Kit (Dektite)*3. Support Straps*4. Attach Flexi Duct to Bell-Mouth Adaptor using cable tie or ring clamp. Please DO NOT rip the ducting. 5. Isodrive M...
Page 15 - EXAMPLE INSTALLATION FOR TRIPLE MODULES
Page 15 INSTALLATION EXAMPLE INSTALLATION FOR TRIPLE MODULES Sub Main Sub 3-Way Adaptor Min 300 Max 1000 Control Module Control Module Mains Plug Mains Plug Motor Power Lead Motor Power Lead Min 300 Max 1000 Main Sub Sub 3-Way Adaptor Min 300 Max 1000 Min 300 Max 1000 200 120 500 420 205 3-WAY ADAPT...
Page 16 - Example Installation for Multiple Modules
Page 16 INSTALLATION 4-Way Adaptor Connect to 200mm flexi ducting Mounting points Ducting 550 700 205 Example Installation for Multiple Modules Sub Sub Sub Main 4-Way Adaptor Control Module Mains Plug Motor Power Lead Min 300 - Max 1000 Min 300 - Max 1000 Measurements in mm. Measurements in mm. NOTE...
Page 17 - EXAMPLE INSTALLATION FOR TWIN MODULES
Page 17 INSTALLATION Sub 2-Way Adaptor Main Min 300 Max 1000 EXAMPLE INSTALLATION FOR TWIN MODULES 2-WAY ADAPTOR Measurements in mm. Measurements in mm. 155 315 325 120/150 150/200 NOTE: Please take note to the minimum and maximum spacing between each module. This is important as it will affect the ...
Page 21 - ISODRIVE MOTOR SETUP; protection on the rangehood and
Page 21 INSTALLATION ISODRIVE MOTOR SETUP NOTEPlease refer to the Isodrive motor installation guide for more details on flexi ducting installation and Isodrive motor installation. FLEXIBLE DUCTING INSTALLATION Please do not crush or kink flexi ducting, as it will reduce air flow and may cause noise ...
Page 22 - OPERATION; REMOTE CONTROL USAGE
Page 22 OPERATION REMOTE CONTROL USAGE Starting the rangehood for the first time using the remote control:Put the safety switch ON (this switch is inside the main rangehood). Wait about 5 seconds for the circuit to test the memory. 1 2 3 4 The rangehood has a 4-speed remote control device. The butto...
Page 24 - FILTERS; Latch A; CLEANING AND MAINTENANCE; Catch A
Page 24 FILTERS • For this appliance to function effectively, regular maintenance is a must. • The function of the filter is to absorb the grease particles emitted during cooking. • Blocked filters and heavy oil deposits restrict airflow and may cause the motor to overheat and become a fire hazard. ...
Page 25 - SURFACES; alcohol on the exterior of the
Page 25 CLEANING AND MAINTENANCE SURFACES The surface of the rangehood can be cleaned with warm soapy water and a soft sponge / cloth. • Never use abrasive detergents, scouring pads, steel wool or solvents on ANY part of this appliance. • Rinse with clean water and ensure that the appliance is compl...
Page 26 - heat for a short period of time after being switched off.
Page 26 CLEANING AND MAINTENANCE TYPE 3 (LED Plate): Replacing the LED Plate 11W (Mod. Modular) NOTE: Make sure the device is disconnected from the electrical power supply.Step 1Open the door of the Paradigma hood. Remove the filter and disconnect the light connector. Your rangehood may have multipl...
Page 28 - TROUBLESHOOTING
Page 28 TROUBLESHOOTING COOKING WITH INDUCTION COOKTOPS Cooking with an induction or similar cooktop, may produce condensation on the rangehood.Unlike basic electric or gas cooking, induction cooktops heat food and liquid instantly, which in turn, produces vapours rapidly. Because of this faster pro...
Page 29 - appliance by yourself. Always
Page 29 TROUBLESHOOTING Before you contact the technical service department, make sure that the product is plugged in and power is supplied.• Do not take any action that will damage the product. Check electric c onnection. V oltage o f the electric ne tw ork should be be tw een 220 - 240V , r angeho...
Page 30 - FAULTY INSTALLATION
Page 30 TROUBLESHOOTING Calling the Technical Assistance Service HotlineIn the event that the failure is not due to the faults mentioned in Trouble Shooting, contact the Customer Service.In Australia, Customer Service 1300 829 066In New Zealand, Customer Service 0800 200 510 Lodging an online Servic...
Page 31 - TECHNICAL SPECIFICATIONS
Page 31 TECHNICAL SPECIFICATIONS Model: CC-INARTSFeeding Voltage: 220-240V 50Hz Max Lamp Power: 10 x GLED Square 55 x 55mm 2.1W 12V 4000k 1710 2000 885 420 ø 200 7 00 1000 Cutout: 950 2000 Cutout: 1950 885 64 Min 210 - Max 335 1000 800 350 350 350 350 15 0
Page 34 - DISCLAIMER
Page 34 DISCLAIMER Under our policy of continuous product development, product specifications may change without notice. Prospective purchasers should therefore check with the retailer to ensure this publication correctly describes the products being offered for sale. All information supplied is to ...
Page 35 - NOTES