Page 2 - Welcome
Page 2 Welcome Thank you for purchasing your new Schweigen Isodrive system. To get the maximum output from this unit, please read through this guide before use and installation. This guide contains important information on the correct use and maintenance of the unit, as well as important safety note...
Page 3 - Index
Page 3 Index 1. Welcome _____________________________________________________________________________________2 2. Your Safety Receiving your rangehood ______________________________________________________________________ 4 Before Installation ________________________________________________________...
Page 4 - Before Installation; Electrical Cord; RECEIVING YOUR RANGEHOOD
Page 4 2. Your Safety This appliance is not intended for use by person/s (including children) with reduced physical, sensory or mental capabilities, or lack of experience and/or knowledge. Unless the person has been given supervision or instruction concerning the use of the appliance by a person res...
Page 5 - Motor Features; General Notes on Installation and Use
Page 5 2. Your Safety This guide is for the installation of the Isodrive motor system after the rangehood has been mounted on the wall or roof. (Refer to rangehood installation manual on how to install the rangehood). NOTE: All PVC pipe and flexi ducting measurements are referring to inside measurem...
Page 7 - Isodrive Motor; NOTE
Page 7 3. Description Isodrive Motor Included in the box: 1. Isodrive 1600 motor (405W x 220H mm approx.) Approx. 3 metre, 10amp cable and standard male plug 2. Fire resistant 150mm (160mm OD 1 ) PVC riser pipe Note: Cable cut-out at the bottom end only 3. Flexible ducting Approx. 6 metres, 200mm (2...
Page 8 - Roof Installation
Page 8 4. Installation Roof Installation Recommended duct length: 1600 motor — 5 to 6 metres. Mount 150mm (ISD) rigid PVC pipe securely to beams, trusses or other appropriate structures: refer figure 1. The pipe should be mounted vertically with the roof penetration being sealed using a Dektite or o...
Page 12 - Installation Through Wall with Back Draught Shutter
Page 12 Installation Through Wall with Back Draught Shutter Due to the weight and to create stability for the Isodrive 1600 motor, it is require to use a hanging bracket. Warranty will be void if a hanging bracket is not used. F igure 7 *Optional parts are available from Schweigen, please contact 13...
Page 13 - Flat Roof Installation; IMPORANT
Page 13 Figure 4 Flat Roof Installation Flat roof mounting using optional mounting flange*. PED Engage locking screws in holes Seal 3 holes in stepped surface Seal between mounting flange and cover Up-stand and capping Power supply cord passing through pipe slots NOTE: Cut 150mm PVC stormwater pipe ...
Page 14 - Fan Unit Shutter Assembly for Isodrive 1600
Page 14 Fan Unit Shutter Assembly for Isodrive 1600 1. Assemble by fitting shutter assembly into fan inlet shroud moulding, ensuring that attaching screws align with holes. Alignment can be checked visually by folding in shutter flaps. 2. Fully tighten both screws and re-check fitment into holes. 3....
Page 15 - Twin Motor Installation
Page 15 Twin Motor Installation (suitable for rangehoods with two 200mm outlets) Where two motors are to be used, follow the method below. Each motor should have a separate flue pipe. Refer figure 9. The two motors can be wired by an electrician. Connect to main power Connect to motor Computer box C...
Page 17 - Single Motor Installation Twin 200mm Outlet
Page 17 Figure 11 Roof mount option Single Motor Installation Twin 200mm Outlet (suitable for rangehoods with two 200mm outlets and one 1600 Isodrive motor) This is for use where one motor is to be used and there are two 200mm outlets, refer figure 11. Try to keep length of flexible ducting as even ...
Page 18 - Measurements for Isodrive 1600
Page 18 5. Measurements Measurements for Isodrive 1600 (Not to Scale) 148mm 90mm 35mm 405mm 220mm 440mm 160mm 225mm 190mm Dektite Motor weight: 6kg net.Shutter assembly is not shown in the diagram.
Page 19 - Flexible Ducting
Page 19 6. Flexible Duct Flexible Ducting Flexible ducting must be fully extended and cut to the required length upon installation. Maximum fan performance will not be achieved unless the ducting is fully extended. Failure to fully extend ducting results in a smaller air passage and lower airflows. ...
Page 21 - Securing Flexible Duct
Page 21 6. Flexible Duct Securing Flexible Duct Flexible duct must be installed with supports at maximum intervals of 1.5 metres. Flexible ductwork can be supported by using good quality gaffer or aluminium foil tape. Provided that it does not restrict the internal diameter of the ducting. Ducting i...
Page 22 - Parts List for Isodrive 1600
Page 22 7. Parts List Parts List for Isodrive 1600 9 3 1 5 4 6 7 3 18 19 20 21 22 23 17 16 11 12 13 14 15 24 25 2 10 23a OR For wall installation with no back drought system or flat roof installation.
Page 26 - Notes