Sanyo KS1872 - Manual

Sanyo KS1872

Sanyo KS1872 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
Page: / 25

Table of Contents:

  • Page 2 – SPECIAL PRECAUTIONS; ... In a Ceiling or Wall; WARNING
  • Page 3 – CAUTION
  • Page 4 – Installation Site Selection; Drain hose; Front View; No additional charge of compressor oil is necessary.
  • Page 6 – N O T E; Air di
  • Page 7 – How to Install the Indoor Unit; -1. Remove the Rear Panel from the Unit; Also avoid areas where elec-
  • Page 8 – Plastic cover; Table 4; Rawl pl
  • Page 9 – Thermi
  • Page 10 – General precautions on wiring; Frame
  • Page 11 – regulations when carrying out the installation.; INDOOR
  • Page 12 – Wiring
  • Page 13 – Solid wire
  • Page 14 – Cover; Push; nsu
  • Page 15 – Refri
  • Page 16 – Condensation; Slant
  • Page 17 – How to Install the Outdoor Unit; -1. Wiring Instructions for the Outdoor Unit; nu
  • Page 18 – Refrigerant Tubing; -2. Flaring Procedure with a Flare Tool; Deburring; Flare tool; If the; us
  • Page 19 – Indoor unit; Clamp; Insulation; Tightening Torque
  • Page 20 – Required time for evacuation when
  • Page 21 – Narrow tube
  • Page 22 – ION; OPERATION lamp
  • Page 23 – Pump Down; (1) Connect the Lo side charging hose of the manifold; Basic Functions of the Service Valves; Action; Wide Tube Service; PUSH
  • Page 24 – Remote Control Unit Installation Position; Hole; To take out the remote control unit, pull it forward.
  • Page 25 – -1. Address Setting of the Remote Control Unit; un; ACL button
Loading the manual

85264189988000 © SANYO 2006

In Canada

SANYO FISHER COMPANY

SANYO Canada Inc.

A DIVISION OF SANYO NORTH AMERICA CORPORATION

300 Applewood Crescent, Concord

21605 Plummer Street

Ontario, L4K 5C7, Canada

Chatsworth, CA 91311 U.S.A.

W

Contents

Page

IMPORTANT!
Please Read Before Starting
.................................. 2

1.

GENERAL .......................................................... 3
1-1. Tools Required for Installation (not supplied)
1-2. Accessories Supplied with Unit
1-3. Optional Copper Tubing Kit
1-4. Type of Copper Tube and Insulation Material
1-5. Additional Materials Required for Installation

2.

INSTALLATION SITE SELECTION ................... 4
2-1. Indoor Unit
2-2. Outdoor Unit
2-3. Baffle Plate for the Outdoor Unit

3.

HOW TO INSTALL THE INDOOR UNIT ............. 7
3-1. Remove the Rear Panel from the Unit
3-2. Make a Hole
3-3. Install the Rear Panel on the Wall
3-4. Remove the Grille to Install the Indoor Unit
3-5. Shape the Indoor Side Tubing
3-6. Wiring Instructions
3-7. Recommended Wire Length and Diameter
3-8. Wiring Instructions for Inter-unit Connections
3-9. Mounting
3-10. Drain Hose

4.

HOW TO INSTALL THE OUTDOOR UNIT ....... 17
4-1. Wiring Instructions for the Outdoor Unit

5.

REFRIGERANT TUBING .................................. 18
5-1. Use of the Flaring Method
5-2. Flaring Procedure with a Flare Tool
5-3. Caution before Connecting Tubes Tightly
5-4. Connecting Tubing between Indoor and

Outdoor Units

5-5. Insulation of Refrigerant Tubing
5-6. Taping the Tubes
5-7. Finishing the Installation

6.

AIR PURGING ................................................... 20

I

Air Purging with a Vacuum Pump (for Test Run)

I

Basic Functions of the Service Valves

I

Pump Down

INSTALLATION INSTRUCTIONS

Model Combinations

Combine indoor and outdoor units only as listed
below.

Indoor Unit

Outdoor Unit

KS1872

C1872

CL1872

KS2472

C2472

CL2472

Power Source:
60 Hz, single-phase, 230/208 V

– Inverter Split System Air Conditioner –

COOL / DRY Model

This air conditioner uses the new refrigerant R410A.

Be sure to read the yellow instruction sheet

attached to the outdoor unit for models using the

new refrigerant R410A.

The illustrations are based on the typical appearance of

a standard model. Consequently, the shape may differ

from that of the air conditioner that you are installing.

N O T E

7.

REMOTE CONTROL UNIT INSTALLATION
POSITION
......................................................... 24
7-1. Mounting on a Wall

8.

ADDRESS SWITCH .......................................... 25
8-1. Address Setting of the Remote

Control Unit

05-326 AirCon_85264189988000 12/5/05 3:35 PM Page a

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - SPECIAL PRECAUTIONS; ... In a Ceiling or Wall; WARNING

2 IMPORTANT! Please Read Before Starting This air conditioning system meets strict safety and operatingstandards. As the installer or service person, it is an importantpart of your job to install or service the system so it operatessafely and efficiently. For safe installation and trouble-free opera...

Page 3 - CAUTION

3 1. General This booklet briefly outlines where and how to install the air conditioning system. Please read over the entire set of instructions for the indoor and outdoor units and make sure all accessory parts listed are with the system before beginning. 1-1. Tools Required for Installation (not s...

Page 4 - Installation Site Selection; Drain hose; Front View; No additional charge of compressor oil is necessary.

4 1-5. Additional Materials Required for Installation 1. Refrigeration (armored) tape 2. Insulated staples or clamps for connecting wire (See local codes) 3. Putty 4. Refrigeration lubricant 5. Clamps or saddles to secure refrigerant tubing 2. Installation Site Selection 2-1. Indoor Unit AVOID: G di...

Other Sanyo Models