Page 3 - safety information; WARNING; Make sure the machine is grounded to prevent electric shock.; FOR INSTALLATION; Extending the power line may result in electric shock or fire.
03 ENGLISH safety information Before using your new air conditioner, please read this manual thoroughly to ensure that you know how to safely and efficiently operate the extensive features and functions of your new appliance.Because the following operating instructions cover various models, the char...
Page 4 - Failing to do so may result in electric shock or fire.
04 safety information The installation of this appliance must be performed by a qualified technician or service company. • Failing to do so may result in electric shock, fire, explosion, problems with the product, or injury. Install a switch and circuit breaker dedicated to the air conditioner. • Fa...
Page 5 - This may result in electric shock or fire.
05 ENGLISH FOR INSTALLATION CAUTION Install your appliance on a level and hard floor that can support its weight. • Failing to do so may result in abnormal vibrations, noise, or problems with the product. Install the drain hose properly so that water is drained correctly. • Failing to do so may resu...
Page 6 - FOR POWER SUPPLY; FOR USING
06 safety information FOR POWER SUPPLY CAUTION When not using the air conditioner for a long period of time or during a thunder/lightning storm, cut the power at the circuit breaker. • Failing to do so may result in electric shock or fire. FOR USING WARNING If the appliance is flooded, please contac...
Page 7 - Do not touch the circuit breaker with wet hands.; This may result in electric shock.; Do not strike or pull the air conditioner with excessive force.; This may result in fire, injury, or problems with the product.
07 ENGLISH Do not touch the circuit breaker with wet hands. • This may result in electric shock. Do not turn the air conditioner off with the circuit breaker while it is operating. • Turning the air conditioner off and then on again with the circuit breaker may cause a spark and result in electric s...
Page 8 - Do not place objects or devices under the indoor unit.; Failing to do so may result in injury, death or property damage.
08 safety information If any foreign substance such as water has entered the appliance, cut-off the power supply and contact the nearest service centre. • Failing to do so may result in electric shock or fire. Do not attempt to repair, disassemble, or modify the appliance yourself. • Do not use any ...
Page 9 - Do not operate the appliance with wet hands.; Do not drink the water from the air conditioner.; The water may be harmful to humans.
09 ENGLISH Do not stand on top of the appliance or place objects (such as laundry, lighted candles, lighted cigarettes, dishes, chemicals, metal objects, etc.) on the appliance. • This may result in electric shock, fire, problems with the product, or injury. Do not operate the appliance with wet han...
Page 10 - FOR CLEANING; Do not clean the inside of the air conditioner by yourself.; Failure to do may result in damage, electric shock or fire.
10 safety information For use in Europe: This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a sa...
Page 11 - contents
11 ENGLISH contents Correct Disposal of This Product (Waste Electrical & Electronic Equipment) (Applicable in countries with separate collection systems) This marking on the product, accessories or literature indicates that the product and its electronic accessories (e.g. charger, headset, USB c...
Page 12 - viewing your air conditioner; Floor standing unit
12 viewing your air conditioner Congratulations on the purchase of the air conditioner. We hope you enjoy the features of your air conditioner and stay cool or warm with optimal efficiency. Please read the user manual to get started and to make the best use of the air conditioner. Floor standing uni...
Page 13 - using your air conditioner; Tips on using your air conditioner
13 ENGLISH using your air conditioner Tips on using your air conditioner Here are some tips that you would follow when using your air conditioner. TOPIC RECOMMENDATION Cooling • If current outside temperatures are much higher than the selected indoor temperature, it may take time to bring the inner ...
Page 14 - Cleaning the filter
14 cleaning and maintaining the air conditioner Cleaning the filter Before cleaning the indoor unit, be sure to turn off the auxiliary power switch. Air filter Washable air filter captures large particles from the air. The filter is cleaned with a vacuum or by hand washing. 1. Unscrew the screws (8)...
Page 16 - maintaining your air conditioner; Periodical checks
16 cleaning and maintaining the air conditioner maintaining your air conditioner If the air conditioner will not be used for an extended period of time, dry the air conditioner to maintain it in best condition. 1. Dry the air conditioner thoroughly by operating in Fan mode for 3 to 4 hours and turn ...
Page 17 - Internal protections via the unit control system
17 ENGLISH Internal protections via the unit control system This internal protection operates if an internal fault occurs in the air conditioner. Type Description Against cold air The internal fan will be off to against cold air when the heat pump is heating. de-ice cycle The internal fan will be of...
Page 18 - appendix; Troubleshooting
18 appendix Troubleshooting Refer to the following chart if the air conditioner operates abnormally. This may save time and unnecessary expenses. PROBLEM SOLUTION The air conditioner does not operate immediately after it has been restarted. • Because of the protective mechanism, the appliance does n...
Page 19 - Operation ranges; model specification (Weight and dimension)
19 ENGLISH Operation ranges The table below indicates the temperature and humidity ranges the air conditioner can be operated within. Refer to the table for efficient use. MODE OPERATIONAL TEMPERATURE INDOOR HUMIDITY IF OUT OF CONDITIONS INDOOR OUTDOOR COOLING 18˚C to 32˚C -5˚C to 48˚C 80% or less C...
Page 20 - Information about Refrigerant
20 Information about Refrigerant Important information: regulation regarding the refrigerant used This product contains fluorinated greenhouse gases. Do not vent gases into the atmosphere. • If the system contains 5 tCO 2 e or more of fluorinated greenhouse gases, it must be checked for leakage at l...
Page 21 - Selecting the Installation Location; Indoor unit installation; installing your air conditioner; Installation Part
21 ENGLISH Installation Part Selecting the Installation Location Preparing for installation Decide the installation location, with the consideration of the following conditions, under user’s approval. Refrigerant pipe work must be done before installing the indoor unit. ▶ Place where air flow is not...
Page 22 - Connecting the Refrigerant Pipe; Leak test; Performing Leak Test & Insulation; Insulation
22 Connecting the Refrigerant Pipe There are two refrigerant pipes of differing diameters: A smaller one for the liquid refrigerant. A larger one for the gas refrigerant. The inside of copper pipe must be clean & has no dust. The connection procedure for the refrigerant pipes varies accord...
Page 23 - Drain pipe and Drain hose Installation
23 ENGLISH 5. Select the insulation of the refrigerant pipe. Insulate the gas side and liquid side pipe referring to the thickness according to the pipe size. Indoor temperature of 30°C and humidity of 85% is the standard condition. If install in a high humidity condition, use one grade thicker ...
Page 24 - Power and communication cable connection; Wiring Work
24 Water leakage test Pipe insulation 1. Pour water to the hole for the drain test or drain pan of the indoor unit as shown in the figure. (About 1ℓ) 2. Make sure that draining is done properly by checking end of the drain pipe. 3. If water leakage occurs, check the horizontality of the indoor unit,...
Page 25 - Specification of electronic wire; Selecting compressed ring terminal; Connecting power for optional product
25 ENGLISH Specification of electronic wire Power supply MCCB ELB or ELCB Power cable Earth cable Communication cable Max : 242V Min : 198V XA XA, 30mmA 0.1 s 2.5mm 2 2.5mm 2 0.75~1.5mm 2 ※ Run transmission wiring between the indoor and outdoor units through a conduit to protect against external for...
Page 26 - Setting an indoor unit address and installation option; The procedure of option setting; AM
26 Setting an indoor unit address and installation option Set the indoor unit address and installation option with remote controller option. Set the each option separately since you cannot set the ADDRESS setting and indoor unit installation setting option at the same time. You need to set twice whe...
Page 30 - 2 series installation option
30 Setting an indoor unit address and installation option(Continued) 1. Check whether power is supplied or not. - When the indoor unit is not plugged in, there should be additional power supply in the indoor unit. 2. The panel(display) should be connected to an indoor unit to receive option. 3. Set ...
Page 33 - 5 series installation option
33 ENGLISH Setting an indoor unit address and installation option(Continued) (*5) This function can be applied to 4 Way Cassette and Mini 4 Way Cassette only. If the air conditioner operates the heating mode immediately after finishing the cooling mode, the condensated water in the drain pan becomes...
Page 36 - Changing a particular option
36 Changing a particular option Option SEG1 SEG2 SEG3 SEG4 SEG5 SEG6 Explanation PAGE MODE The option mode you want to change The tens’ digit of an option SEG you will change The unit digit of an option SEG you will change The changed value Remote Controller Display Indication and Details Indication...
Page 37 - Setting the function switch
37 ENGLISH Setting Main Address The MAIN address is for communication between the indoor unit and the outdoor unit. Therefore, you must set it to operate the air conditioner properly. You can set the MAIN address from ‘00’ to ‘99’ by mixing SW01 and SW02. The MAIN address from ‘00’ to ‘99’ shoul...
Page 38 - QUESTIONS OR COMMENTS?
QUESTIONS OR COMMENTS? Samsung, PO Box 12987, Blackrock, Co. Dublin. IEor Euro QA Lab. Saxony Way, Yateley, Hampshire GU46 6GG, UK DB68-03677A-09 COUNTRY CALL OR VISIT US ONLINE AT UK 0333 000 0333 www.samsung.com/uk/support IRELAND (EIRE) 0818 717100 www.samsung.com/ie/support GERMANY 06196 77 555 ...