Page 2 - English; Contents; Safety Information; PRODUCT FICHE (ENERGY LABELLING OF AIR CONDITIONERS)
2 Contents English Contents Safety Information Safety Information 3 General informationInstalling the unitPower supply line, fuse or circuit breaker Installation Procedure 6 Step 1 Choosing the installation locationStep 2 UnpackingStep 3 Checking and preparing accessoriesStep 4 Drilling a hole throu...
Page 3 - ormation; WARNING; General information
3 English Safety Inf ormation Carefully follow the precautions listed as below because they are essential to guarantee the safety of SAMSUNG product. WARNING ∙ Always disconnect the air conditioner from the power supply before servicing it or accessing its internal components. ∙ Verify that installa...
Page 4 - Installing the unit; IMPORTANT; CAUTION
4 Safety Information English Safety Inf ormation Installing the unit IMPORTANT : When installing the unit, always remember to connect first the refrigerant tubes, then the electrical lines. Always disassemble the electric lines before the refrigerant tubes. ∙ Upon receipt, inspect the product to ver...
Page 6 - oc; Indoor unit; Top view; Outdoor unit; Installation Procedure
6 English Installation Pr oc edur e Installation Procedure Step 1 Choosing the installation location Determine the installation location considering the following conditions and obtain the user approval. Indoor unit ∙ Install the unit where the pipes and cables can be easily connected to the outdoor...
Page 7 - Outdoor unit installation request; When installing more than 1 outdoor unit
7 English Installation Pr oc edur e Installation Procedure ∙ Construct a protection wall made of solid material such as concrete to block sea breeze. Make sure that its height and width are 1.5 times greater than the size of the outdoor unit. In addition, secure a space larger than 600 mm between th...
Page 8 - Fixing the outdoor unit in place
8 Installation Procedure English Installation Pr oc edur e WARNING ∙ After installing the outdoor unit, apply rust inhibitor on the internal pipes and heat exchanger. – Airborne corrosive gas such as sulfur compounds, hydrogen sulfide, and ammonia, or salty dust may cause pipe corrosion. This corros...
Page 9 - Step 2 Unpacking; Unpacking the indoor unit; Step 4 Drilling a hole through a wall
9 English Installation Pr oc edur e Step 2 Unpacking Unpacking the indoor unit 1 Open the indoor unit package. 2 Remove the top and middle cushions. 3 Remove the bottom cushion. Unpacking the outdoor unit 1 Pull out the outdoor unit from the package. 2 Remove the top cushion. 3 Remove the 4 screws f...
Page 10 - NOTE; Outer diameter
10 Installation Procedure English Installation Pr oc edur e Step 5 Taping the pipes, cables, and drain hose 1 Wrap the refrigerant pipes with the provided insulation. This wrapping minimises condensation. Insulation Refrigerant pipes 2 Wind the refrigerant pipes, power cable, communication cable, an...
Page 11 - Outer Diameter; ∙ During installation, make sure that there is no gas; ∙ The appearance of the unit may be different from the
11 English Installation Pr oc edur e 1 Connect each assembly pipe to the appropriate valves on the indoor and outdoor units and fasten the flare nuts. 2 As depicted in the illustration below, tighten the flare nut manually, and then apply the following torque with a torque wrench. Indoor unit Liquid...
Page 12 - Indoor power supply
12 Installation Procedure English Installation Pr oc edur e Step 7 Optional: Cutting and flaring the pipes 1 Make sure that you have the required tools; pipe cutter, reamer, flaring tool, and pipe holder. 2 If you want to shorten the pipes, cut it with a pipe cutter, making sure that the cut edge re...
Page 13 - Thickness of the; Connecting the cable to the power terminal; Connecting the cables
13 English Installation Pr oc edur e CAUTION ∙ Use rated cables or products only, with heat resistance over 105°C, as well as properly rated switches or fuses in the cabinet panel. ∙ Make sure that the cables connected do not produce sparks around the auxiliary power switch or that they are not inst...
Page 14 - ∙ When connecting the communication and outdoor-to-
14 Installation Procedure English Installation Pr oc edur e Entire system diagram ELB NFB Single phase 220 to 240V, 50 Hz Outdoor-to-indoor power cable Main power cable Outdoor unit Indoor unit Electrical panel Earthing Ground wire Communication cable Power wiring diagram 1(L) 2(N) L N F1 F2 Outdoor...
Page 15 - Main power cable specifications
15 English Installation Pr oc edur e Main power cable specifications The power cable is not supplied with air conditioner. ∙ Select the power supply cable in accordance with relevant local and national regulations. ∙ Wire size must comply with the applicable local and national code. ∙ Specifications...
Page 16 - Method 1
16 Installation Procedure English Installation Pr oc edur e Step 9 Optional: Extending the power cable 1 Prepare the following tools. Tools Spec Shape Crimping pliers MH-14 Connection sleeve (mm) 20 x Ø6.5 (HxOD) Insulation tape Width 19 mm Contraction tube (mm) 70 x Ø8.0 (LxOD) 2 As shown in the fi...
Page 17 - Step 10 Checking the earthing; Step 11 Performing gas leakage test
17 English Installation Pr oc edur e CAUTION ∙ Make sure that the connection parts are not exposed to outside. ∙ Be sure to use insulation tape and a contraction tube made of approved reinforced insulating materials that have the same level of withstand voltage with the power cable. (Comply with the...
Page 18 - Step 12 Evacuating the air; Unit
18 Installation Procedure English Installation Pr oc edur e 1 Connect the charging hose of low pressure side of manifold gauge to the packed valve having a service port as shown at the figure. NOTE ∙ The designs and shape are subject to change according to the model. 2 Open the valve of the low pres...
Page 20 - Pressure table for each temperature; Cooling operation
20 Installation Procedure English Installation Pr oc edur e Pressure table for each temperature If extra refrigerant charging is required due to gas leakage or product relocation, see the following table. Cooling operation Unit: [kPa, G] Indoor temperature (°C) (Dry bulb / Wet bulb) Outdoor temperat...
Page 21 - ∙ When the hole of the drain hose on the wall is lower; ∙ When the hole of the drain hose on the wall is higher; Step 16 Performing drainage test
21 English Installation Pr oc edur e Step 15 Installing and connecting the drain hose 1 Wrap the drain hose with the provided insulation. This wrapping minimises condensation. Drain hose Insulation 2 Insert the end of the drain hose to the extension drain hose to make a connection. 3 Tightly wrap th...
Page 22 - Step 17 Checking the earthing
22 Installation Procedure English Installation Pr oc edur e CAUTION ∙ Install the drain hose in a downward direction. ∙ Water leakage may occur when the drain hose is not firmly fixed with a cable tie or tape. ∙ If there is any foreign substance in the drain pan, it may clog the drain hose. Be sure ...
Page 23 - short
23 English Installation Pr oc edur e 6 View mode: When the K4 switch is pressed, you can see information about our system state, as detailed below. K4 short push Display contents SEG1 SEG2 SEG3 SEG4 Unit 1 Order frequency 1 Hundreds digit Tens digit Units digit Hz 2 Current frequency 2 Hundreds digi...
Page 24 - Off; Appendix
24 Installation Procedure English Installation Pr oc edur e 7 DIP switch option ON 1 2 3 4 1 2 3 4 ON ∙ DIP switch (SW507) option On (default) Off Switch 1 Auto address Manual address Switch 2 Disable snow prevention control Enable snow prevention control Switch 3 Silence mode option Switch 4 – When...
Page 27 - GWP; Pdesignc
27 English Appendix [German-DE] [Greek-EL] [Dutch-NL] [Polish-PL] DELEGIERTE VERORDNUNG (EU) Nr. 626/2011 DER KOMMISSION ΚΑΤ’ ΕΞΟΥΣΙΟΔΌΤΗΣΗ ΚΑΝΟΝΙΣΜΌΣ (ΕΕ) αριθ. 626/2011 ΤΗΣ ΕΠΙΤΡΟΠΉΣ GEDELEGEERDE VERORDENING (EU) VAN DE COMMISSIE Nr. 626/2011 ROZPORZĄDZENIE DELEGOWANE KOMISJI (UE) nr 626/2011 Prod...
Page 39 - Troubleshooting; Error Code
39 English Appendix Troubleshooting The table below lists the self-diagnostic routines. For some of error codes, you must contact an authorized service centre. If an error occurs during the operation, it is displayed on the outdoor unit PCB LED, both MAIN PCB and INVERTER PCB. No. Error Code Meaning...
Page 41 - Memo
41 English Appendix Memo PAC_IM_ENG.indd 41 2016-06-23 오전 11:51:21