Robertshaw RS6110 - Manual

Robertshaw RS6110

Robertshaw RS6110 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
Page: / 32

Table of Contents:

  • Page 4 – Set Time and Day; Default Settings
  • Page 6 – To Make Changes in the Schedule:
  • Page 7 – To Make Changes to the Settings
  • Page 10 – Security Lockout to Protect the Settings
  • Page 12 – Schedule Overrides; Temporary Override
  • Page 13 – Origin of Setpoint
  • Page 14 – Troubleshooting; If problems with thermostat cannot be resolved, contact:; or
  • Page 15 – Five Year Limited Warranty
  • Page 16 – NOTES
  • Page 17 – Características; MANUAL DEL USUARIO
  • Page 20 – Hora Refrigeración Calefacción °F
  • Page 22 – Para cambiar la programación:; Hora
  • Page 23 – Para cambiar los valores ingresados
  • Page 26 – ADVERTENCIA: Un ciclo corto inconveniente
  • Page 28 – Modo Sobrecontrol temporario
  • Page 29 – Origen del valor deseado; Vac
  • Page 31 – Garantia Limitada de 5 años; Si no puede resolver algún problema con su termostato,
Loading the manual

Thank you for purchasing a Robertshaw RS5000 Series programmable

thermostat. This user’s manual will guide you through the setup of the

RS5110 single stage and the RS5220 two stage thermostats. The

thermostat should already be mounted and correctly wired. The default

settings will enable the thermostat to operate efficiently. Before making

any changes to the schedule read the section on Default Settings.

Features

• Pop-Up Wizard

• Automatic changeover

• Circulating fan

• Worry-Free memory retention

• Easy change battery

• Large back lit display

• Filter change reminder

• Low battery indicator

• Fahrenheit and Celsius displays

• EnergyStar™ compliant

• Dual power

• Adjustable 1

st

stage temperature differential: 0.5 F degrees to

3.0 F degrees (0.5 C degrees to 1.5 C degrees)

• Accuracy within ±1 F degree

• Universal staging on multi-stage units

• Automatic heating shutdown if temperature exceeds 99°F (37°C)

• Keypad security lockout

• 4 events per day for heating and cooling

• 5-2 day scheduling

• User settable Hi and Lo temperature limits

• Vacation setpoint override

1

RS

4110

RS

5110

RS

6110

RS

4220

RS

5220

RS

6220

352-00056-001

USERS MANUAL

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 4 - Set Time and Day; Default Settings

Set Time and Day To adjust the time and day settings press the SET TIME button. The hour will flash. If a button is not pushed within 10 seconds the thermostat returns to operation. To change the settings: 1. Use the and buttons to change the flashing number. 2. Press the SET TIME button to move thr...

Page 6 - To Make Changes in the Schedule:

START/STOP SCHEDULE: Switches between running a schedule and manual (permanent override). Cancels a temporary or vacation override. EDIT SCHEDULE: Use this button to start editing the schedule. Push repeatedly to move through the selections. VACATION: Used to set a temporary setpoint for a number of...

Page 7 - To Make Changes to the Settings

If a button is not pushed within 30 seconds the thermostat returns to operation. Use the or to change the hour of the start time if desired. Push EDIT SCHEDULE to move to minutes. Use the or to change the minutes of the start time if desired. Push EDIT SCHEDULE to move to the heat or cool temperatur...