Robertshaw 9520 - Manual

Robertshaw 9520

Robertshaw 9520 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
Page: / 12

Table of Contents:

  • Page 2 – Features; Step 1: Replacing Existing Thermostat; Figure 1
  • Page 3 – Table 1; Recycling Thermostat; Turn off power to the heating
  • Page 5 – Terminal screws are loosened. Insert wires into terminal strip; FIGURE 4
  • Page 7 – Figure 5; Step 3: Testing the Thermostat; DO NOT SHORT (JUMPER) ACROSS TERMINALS OF GAS VALVE OR
  • Page 8 – Step 4: Customizing Your Thermostat; Setting or Changing; Settings; System; or
  • Page 9 – Changing Temperature Differential; both and buttons; LED Indicators
  • Page 10 – If problems with thermostat cannot be resolved, call:; Troubleshooting; Symptom Remedy
  • Page 11 – Five Year Limited Warranty; warrants to the original contractor installer or; Maple Chase Company; agrees to repair or replace at its option any; Maple Chase Company; shall not be liable for
  • Page 12 – NOTES
Loading the manual

IMPORTANT SAFETY INFORMATION

WARNING:

• Always turn off power at the main power source by unscrewing

fuse or switching circuit breaker to the OFF position before installing,
removing, cleaning, or servicing thermostat.

• Read all of the information in this manual before installing or pro-

gramming this thermostat

• This is a 24V AC low-voltage thermostat. Do not install on voltages

higher than 30V AC.

• All wiring must conform to local and national building and electrical

codes and ordinances.

• Do not short (jumper) across terminals on the gas valve or at the

system control to test installation. This will damage the thermostat
and void the warranty

1

2 Heat / 2 Cool

W

A R R A N T Y

I N T E G R A T E D C O M F O R T S O L U T I O N S

D I G I TA L

N O N - P R O G R A M M A B L E

T H E R M O S TAT

9520

User’s Manual

Quick Start
Installation

110-733D

®

H E AT P U M P

H

!

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Features; Step 1: Replacing Existing Thermostat; Figure 1

Features • Multi-stage heating and cooling control • Zone system compatible as a master thermostat • Multi-colored LED indicators for system status • Low battery indicator. • Fahrenheit/Celsius display option. • Adjustable from 45°F (4°C) to 90°F (32°C). • Accuracy within ± 1 degree. • Adjustable te...

Page 3 - Table 1; Recycling Thermostat; Turn off power to the heating

Table 1 Old Terminal New Label Description R, V-VR or VR-R R 24 VAC Return Y, Y1 or M Y Stage 1 Cooling/HeatingCircuit O or R O Reversing Valve(Cooling Mode) B B Reversing Valve(Heating Mode) F or G G Fan Control Relay Y2 Y2 2nd Stage CoolingCircuit W1 or W2 or W-U W2 2nd Stage HeatingControl L or X...

Page 5 - Terminal screws are loosened. Insert wires into terminal strip; FIGURE 4

11. Terminal screws are loosened. Insert wires into terminal strip (Figure 4) matching the label to the corresponding terminal (see Wiring Diagrams below). Tighten screws. 5 Typical heat pump with cool active reversing valve and auxiliary/emergency heat. O B 9520 WIRING SAMPLE #1 Y1 E G W2 C L R Y2 ...

Other Robertshaw Models

All Robertshaw Other