Installation and service of the Ubbink Rolux® Condensing Concentric Vent System must
be performed by a qualified installer, service agency or the gas supplier.
1.1 Approvals/Codes
The installation must conform with local codes or, in the absense of local codes, the
National Fuel Gas Code, ANSI Z223.1/NFPA 54 and/or CSA B149.1, Natural Gas and
Propane Installation Code.
The maximum vent length, as stated in the Rinnai condensing appliance Installation and
Operation Manual, and these instructions, should never be exceeded. Ubbink Rolux®
Condensing Concentric Vent Systems must be used throughout the entire vent system.
Do not use vent components from other vent manufacturers when using the Ubbink
Rolux® Condensing Concentric Vent System. Unless approved by Rinnai, do not connect
the Ubbink Rolux® Condensing Concentric Vent System into a common vent system.
1.2 Inspection
Before installation, inspect each vent component for damage and correct seal placement.
Do not attempt to fix or install any damaged vent components.
1.3 Condensate
Slope horizontal venting 1/4 in. per foot (25 mm/m) either toward the Rinnai condensing
appliance with an integrated condensate collector or toward the exhaust terminal. Ubbink
prefers pitching the vent 1/4 in. per foot (25 mm/m) toward the Rinnai condensing
appliance.
•
The vent system should be inspected annually for signs of damage or condensate
leaks. If the vent system appears damaged, the Rinnai condensing appliance must
be turned off and the vent system repaired.
•
Refer to local code for horizontal termination above a public walkway, driveway or
area where condensate or vapor could create a nuisance or hazard.
•
Ice can develop in regions of cold climate. A 1/4 in. per foot (25 mm/m)
pitch to the
Rinnai condensing appliance with the use of the condensate collector is
recommended. Ubbink cannot be held liable for personal injury or property damage
due to ice formation.
4 Appliance Connection
Shortening of Vent Extensions
Pipes overlap by 1.25 in. (32 mm).
When cutting to size, add 2 x 1.25 = 2.5 in.
(65 mm) to the extension pipe length (X)
needed for installation.
•
Identify the vent location.
•
Place the 90° vent pipe elbow or horizontal starter adapter on the Rinnai condensing
appliance.
•
Mark position on wall or use template supplied with the Rinnai condensing appliance.
•
Cut hole, and then cover the top of the Rinnai condensing appliance to prevent debris
from entering.
UBBINK BV NL –
6984
AA Doesburg The Netherlands T + 31 (0) 313 480 200 E
-
mail: [email protected] Web: www.ubbink.com
Rolux
®
Condensing Vent System
These Instructions Should Remain with the Rinnai Condensing Appliance for Maintenance
•
The Ubbink Rolux® Condensing Concentric Vent System is considered part of the
Rinnai condensing appliance.
•
The
Rinnai condensing appliance installation and operation manual takes precedence
over this document.
•
Refer to the Rinnai condensing appliance installation and operation manual before
proceeding with the installation of this product.
Introduction
1 Installation Requirements
2 Recommended Vent/Air Intake Terminal Position
•
Ubbink refers to the Rinnai condensing appliance installation and operation manual and/
or national and local codes (such as ANSI Z223.1/NFPA 54 or CGA
-
B149) for the
correct position of the vent and air intake position.*
•
The Rinnai condensing appliance installation and operation manual takes precedence
over this document.
•
Terminals should be positioned to avoid products of combustion entering openings into
buildings or other flues or vents.
•
The Ubbink Rolux® white vent extension material is designed primarily for indoor use. If
used outdoors, the material should be protected for UV
-
radiation (direct sunlight).
* For clearances not specified in ANSI Z223.1/NFPA 54 or CGA
-
B149, please use
clearances in accordance with local installation codes and the requirements of the gas
supplier.
3 General Installation Instructions
Vent connections must be firmly
pressed together so that the gaskets
form an airtight seal. To ensure
optimum joint connection, it is
recommended to secure with three #8 x
1/2 in. self
-
tapping screws. Secure the
vent to the wall or ceiling with pipe
clamps or a perforated hanger iron.
Vent connections extending beyond the
outside of a building or structure should
be enclosed to protect seals and
gaskets.
Horizontal vent lengths must pitch a
minimum 1/4 in./ft. (25 mm/m) or 1° to
the Rinnai condensing appliance.
Note:
See exception for wall terminals
in section
“1.3
Condensate.
”
Joint Connection
Condensate
X
Insert the male end of a vent
component into the female vent top.
The molded line on the male end of
the elbow (X) indicates the
proper insertion depth into the
vent top.
Secure the connection with the
supplied #8 x 1/2 in. self
-
tapping
screw.
5 Shortening of Vent Extensions and Terminals
The 2 in. (60 mm) inner pipe (translucent or black) should always extend 0.4 in. (10 mm)
beyond the white outside pipe on the male end. Always cut the male end of the
component. Deburr the sharp edges as the gaskets can damage, which can result in the
system no longer being airtight.
6 Installation Instructions:
Condensing Horizontal Discharge Vent System
4.5 in. (115 mm)
•
Cut the terminal to length as described in
Section 5. Add 3.9 in. (99 mm) to the wall
thickness as illustrated. The white section of the
termination should not be visible outdoors.
•
After cutting the appropriate length, slide the
horizontal wall terminal through the hole in the
wall.
•
Position the grey rubber wall plate around the male
end of the termination.
•
Position the inner white wall plate between the wall
and horizontal discharge adapter.
•
Slide the male end of the termination in the
horizontal discharge adapter.
•
Fill the gaps between the wall and vent pipe
penetration with a weather
-
proof sealant.
7 Installation Instructions:
Condensing Vertical Discharge Vent System
•
Identify the vent location.
•
Determine the location where the roof
discharge termination will be installed.
•
Taking into account the angle of the roof, cut
the hole with a dimension that allows the
vertical discharge roof termination to be
installed.
̶
6 in. x 6 in. (150 mm x 150 mm) hole for
flat roof
̶
9 in. x 6 in. (225 mm x 150 mm) hole for
12/12 pitch (45°)
̶
12 in. x 6 in. (300 mm x 150 mm) hole for
16/12 pitch (55°)
•
After cutting the hole, cover the top of the
Rinnai condensing appliance to prevent
debris from entering.
Mounting the
Vent System
Vent connections must be firmly pressed together so that the
gaskets form an airtight seal. Secure the system with the
supplied vent pipe clamp or perforated hanger iron.
To ensure optimum joint connection, it is recommended to
secure with three #8 x 1/2 in. self
-
tapping screws.
Note:
Install a support bracket on each extension, or at least
every 39 in. (991 mm). For vertical runs, install a support
bracket on each extension, or at least every 78 in. (1,981 mm).
8 Installation Example
Pitch min. 1°
(= 0.25 in./ft)
(= 19 mm/m)
Art.nr. 10000072693 V1.0 12/19
•
The Ubbink Rolux® Condensing Vent System was tested and approved with the
Rinnai® condensing appliance for a maximum flue gas temperature of 230°F (110ºC).
•
Do NOT use this system on any other appliance.
•
Do NOT use this system with other vent products.
•
Improper installation of the vent system and components, or failure to follow all
installation instructions, can result in property damage or serious injury.
WARNING
•
Special Ubbink
-
branded lubricant is supplied with the vent system termination. This
lubricant, or water, is the only approved lubricant for the lubrication of the flue seals.
•
Do not use fat, grease, soap, or other substances, as these can damage the seals,
resulting in malfunctioning of the vent system.
WARNING
Inner
Outer
0.4 in. (10 mm)
X+0.4 in. (X+10 mm)
X=A+3.9 in. (Min.)
X=A+99 mm (Min.)
X
X
Y
1.25 in.
1.25 in.
X
0.4 in. (10 mm)
X + 2.5 in. (X + 65 mm)
Pitch min. 1°
(= 0.25 in./ft)
(= 19 mm/m)
1.4 in.
(35 mm)
2.5 in.
(60 mm)
Vent
Pipe
Clamp
L
2/4 (60/100) Condensing
Horizontal Termination Kit
(Termination, Elbow, Rubber
Wall Plates)
2/4 (60/100) Condensing
Horizontal Starter Adapter
Part #: 229252
2/4 (60/100) Condensing
Vertical Starter Adapter
Part #: 227413
Ø3/5 in. (80/125) connection
Ø2/4 in. (60/100) connection
3
.3
in
.
(8
4
m
m
)
7
.9
in
.
(2
0
0
m
m
)
Maximum Wall
Thickness
“
L
”
Part #
12 in. (305 mm)
229031
21 in. (533 mm)
229032
2/4 (60/100) Condensing Vent
Pipe Extension
Length
“
L
”
Part No.
10 in. (254 mm)
229318
19.5 in. (240 mm)
229319
39 in. (991 mm)
229320
2/4 (60/100) Rubber Wall Plate
Part #: 710265 (White)
Part #: 711262 (Gray)
6
.6
in
.
(1
6
8
m
m
)
2/4 (60/100) Condensing
90° Diverter Nose
Part #: 710202NPP
2/4 (60/100) Condensing
45° Diverter Nose
Part #: 710215NPP
4
.9
in
. (
1
2
4
m
m
)
2.0 in.
(51 mm)
2/4 (60/100) Condensing
45 Degree Elbow (Qty. 2)
Part #: 229208
Retrofit Wall Plate
Part #: 188486 (Gray)
Part #: 188481 (White)
3
.3
5
in
. (
85
m
m
)
4.0 in.
(107 mm)
2/4 (60/100) Condensing
90 Degree Elbow
Part #: 229233
Flashing for Metal Roof*
Part #: 242141
Roof Flashing Assembly
-
Flat*
Part #: 146141
Universal Bug Guard*
Part #: 224042
Roof Flashing*
2/4 (60/100) Condensing 21 in. Wall
Termination (includes 2 wall plates)
Part #: 229033
Roof Pitch
Part No.
Shingle Roofs
Part #
Tile Roofs
1/12 to 6/12
189950
50171949
6/12 to 12/12
189951
50171961
8/12 to 16/12
189952
50171954
*Components are universal for use with 2/4 (60/100) and
3/5 (80
-
125) components.
Ø3/5 in. (80/125) connection
Ø2/4 in. (60/100) connection
8
.6
in
.
(2
1
8
m
m
)
Ø4.0 in. (102 mm)
2/4 (60/100) Vent
Support Bracket
Part #: 224056
4.6 in.
(117 mm)
19
.5
in
. (
4
9
5
m
m
)
2/4 (60/100) Condensing Roof
Termination Extension Kit
Part #: 185348NPP
2/4 (60/100) Condensing
Roof Discharge Termination
20 in. above Roof
Part #: 224359
2/4 (60/100) Thimble
Part #: 224055
Fits 2x4 or 2x6
Wall Construction
4
.1
5
in
. (
1
0
5
m
m
)
2/4 (60/100) Pipe Clamp
Metal
Part #: 169013
2/4 (60/100) Horizontal
Flashing Panel
Part #: 102000022
1
2
.2
5
in
.
(3
1
1
m
m
)
Vertical Vent System
-
Condensate
Pitch for Horizontal Sections
9 Polypropylene (PPtl) Vent Components
Pipe Clamp
Universal Plastic*
Part #: 169044
Y
L
3
8
in
. (
9
6
5
m
m
)
2
0
.3
in
. (
5
1
6
m
m
)
The hole is minimum 4.5 in. diameter (115 mm).
100000678(01)
Refer to the Rinnai condensing appliance installation and operation manual or
Certificate of Compliance to confirm that the Ubbink Rolux® Condensing
Concentric Vent System is approved for your Rinnai condensing appliance.