Rinnai RSEP1S25N - User Manual

Rinnai RSEP1S25N

Rinnai RSEP1S25N Heater – User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
Page: / 40

Table of Contents:

  • Page 2 – nance can cause property damage, injury or death.; Keep this manual in a secure place.; All models approved:
  • Page 3 – TABLE OF CONTENTS; Gas; VENTILATION FOR INDOOR APP’S; IMPORTANT; Installer
  • Page 4 – SULATION IN T HE ROOF—CONDENSATION WILL OCCUR.; WARNING
  • Page 5 – Refer to Page 19; Stainless Steel & Painted Finishes
  • Page 6 – WHEN INSTALLED AS AN OUTDOOR PATIO HEATER; It is the installer; DO NOT INSTALL THIS APPLIANCE IN A RECESS, ALCOVE,; Note: Do not store or place anything directly under heater
  • Page 7 – It is the installer; Note: Do not mount less than 8 ft
  • Page 8 – Horizontal
  • Page 9 – WHEN INSTALLED INDOORS FOR COMFORT OR SPACE HEAT
  • Page 10 – NG Only
  • Page 11 – Or
  • Page 12 – INSTALLATION IN COMMERCIAL AIRCRAFT HANGARS; stalled in accordance with the latest edition of the Standard for; INSTALLATION IN COMM ERCIAL GARAGES AND PARKING STRUCTURES; Parking Structures; INSTALLATIONS OTHER THAN SPACE HEATING
  • Page 13 – INSTALLATION REQUIREMENTS
  • Page 14 – DO NOT INSTALL ANY GAS PIPING IN HEAT ZONES
  • Page 15 – must be regulated to be maximum 0.5 psig; INSTALLATION PROCEDURES
  • Page 17 – Indication of back firing:; must; HEATER SERVICING POSITION:
  • Page 18 – Figure 4: HEATER SERVICE POSITION WITH WALL MOUNT BRACKET; (To simplify illustration the heater is not shown)
  • Page 19 – VENTILATION REQUIREMENTS FOR INDOOR APPLICATION
  • Page 20 – Front View; MOUNTING KIT OPTIONS; ITEM NO
  • Page 21 – Figure 7: MOUNTING OPTIONS
  • Page 22 – Stainless Steel
  • Page 23 – Figure 10: HEATER INSTALLATION: WALL MOUNT BRACKET
  • Page 24 – ELECTRICAL REQUIREMENTS AND THERMOSTAT CONTROL; stage; Zone of 1 To 4 Heaters
  • Page 25 – Flame Failure; SEQUENCE OF OPERATION FOR FENWAL 35; Flame current
  • Page 26 – SPARK IGNITION CIRCUIT; The step; CAUTION; control input terminals was proved, replace the ignition control.
  • Page 27 – Fenwal Control Terminal Designation; with Fenwal 35
  • Page 29 – Stage Switch Control
  • Page 30 – TROUBLESHOOTING GUIDE; IN “SPARK IGNITION CIRCUIT”.
  • Page 31 – CHECK FOR CORRECT MANIFOLD GAS PRESSURE; NOTE: IF CONTROL GOES INTO LOCKOUT, THE SYSTEM CAN BE
  • Page 32 – Plug; COMPLETE THIS COMMISSIONING REPORT AND; Technical commissioning report continues next page; COMMISSIONING REPORT; HEATER MODEL NUMBER :
  • Page 33 – HEATER COMMISSIONING TECHNICAL REPORT; TURE REFERENCE
  • Page 34 – HIGH ALTITUDE INSTALLATION / DERATION; This heater not to be installed at altitude above 6,800 feet.; above; refer to information below; confirm; M ODEL; Supplied; DO NOT
  • Page 35 – Replacement Parts List
  • Page 36 – Replacement Parts List Con; Item Number
  • Page 37 – NOTES
Loading the manual

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - nance can cause property damage, injury or death.; Keep this manual in a secure place.; All models approved:

2 SE+ Series Infrared G as Heater I nstallation and Operatio n Manual NOTICE: Rinnai reserves the right to make changes to equipment and specifications without obligation or notification. This publication, or parts thereof, may not be reproduced in any form, without prior written consent from Rinnai...

Page 3 - TABLE OF CONTENTS; Gas; VENTILATION FOR INDOOR APP’S; IMPORTANT; Installer

3 SE+ Series Infrared G as Heater I nstallation and Operatio n Manual TABLE OF CONTENTS TOPIC PAGE NUMBER IMPORTANT INFORMATION - READ FIRST IM PORTANT WARNINGS ........................... 4 HEATER EXPANSION ................................ 5 GAS CONNECTION .................................... 5 VEN...

Page 4 - SULATION IN T HE ROOF—CONDENSATION WILL OCCUR.; WARNING

4 SE+ Series Infrared G as Heater I nstallation and Operatio n Manual This heater is not for installation in a Class 1 or Class 2 explo- sive environment, nor f or any residential application. If installa- tion of this equipment is in question, consult with local authorities having jurisdiction (Fir...

Other Rinnai Heaters Models

All Rinnai Heaters