Rinnai REU-VB2735WD-US - Manual
Rinnai REU-VB2735WD-US – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
0.0
1.0
2.0
3.0
4.0
5.0
6.0
7.0
8.0
9.0
10.0
0
25
50
75
100
125
150
∆
T – Temperature Rise (°F)
H
o
t
W
at
er
Fl
ow
R
at
e (
gpm
)
R94LSe (VB2735WD-US)
Type of Appliance
Rinnai Model Number
Operation
Minimum/Maximum Gas Rate (Input)
Electrical
Electrical Consumption
Ignition System
Hot Water Capacity
Temperature
Temperature (without remote)
Approved Gas Types
Installation
Energy Factor
Thermal Efficiency
Service Connections
Water Flow Control
Minimum/Maximum Water Supply Pressure
Temperature controlled, continuous flow, gas hot water system;
certified for installation in manufactured (mobile) homes
REU-VB2735WD-US
Forced combustion
9,900 - 199,000 BTU/h (Natural Gas)
10,300 - 199,000 BTU/h (Propane)
Appliance:
AC 120 Volts - 60 Hz
Controller:
DC
12
Volts
Normal
49
watts
Standby 2
watts
Anti-frost protection
104 watts
Direct electronic ignition
Minimum flow rate: 0.26 GPM
Minimum activation flow rate: 0.4 GPM
Maximum flow rate: 9.4 GPM (35° F rise)
98° - 120° F (factory default) Maximum temperature is selectable at
120° F or at 140° F; 98° - 185° F available with the MCC-91
controller for commercial and hydronic applications
120° F (factory default)
Natural or Propane (ensure unit matches gas type)
Outdoor only
Natural Gas: 0.82
Propane: 0.82
Natural Gas: 83%
Propane: 83%
Gas supply: 3/4 inch MNPT
Cold water inlet: 3/4 inch MNPT
Hot water outlet: 3/4 inch MNPT
Water flow sensor, electronic water control device and fixed by-pass
20 - 150 PSI (recommended 30-80 PSI for maximum performance)
© 2010 Rinnai Corporation
R94LSe VB SP 8/2010
FLOW TABLE
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.