Summary
WARNING IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION,SERVICE OR MAINTENANCE CAN CAUSE PROPERTYDAMAGE, PERSONAL INJURY OR LOSS OF LIFE, REFERTO THE OWNER'S INFORMATION MANUAL PROVIDEDWITH THIS APPLIANCE. INSTALLATION AND SERVICEMUST BE PERFORMED BY A QUALIFIED INSTALLER,SERVICE AGENCY OR THE GAS SUP...
FEATURES OF THE RHFE-1004FA UNITS – 1 – SAFETY DEVICES ◆ Clean Heating Forced Flue Type ◆ Easy Operation One-Touch Ignition ◆ Sensible Temperature Control Feature ◆ Comfortable Room Temperature Control and Display ◆ Warm Air Outlet at Floor Level (Keeps Your Feet Warm) ◆ Child Safety Lock ◆ Room Tem...
– 2 – Overcurrent Prevention Device: This is a 5 amp. glass fuse found on P.C. board. Design toshut unit down in case of overcurrent. If fuse blows allindicator lamps will be “OFF”. Power Outage Safety Device: This safety device cuts off gas passage and stopsoperation. Local and state codes must be ...
IMPORTANT POINTS / USAGE AND INSTALLATION MUSTS – 3 – Unpack heater and check for damage. (DO NOT INSTALL DAMAGED HEATER.) If heater isdamaged, contact your supplier for advice. Before installing a heater, check the label for the correct gastype (see label on heater). Refer to local gas authority fo...
DIMENSIONS – 5 – 14 1/16" (357.5) 12 3/8" (315) 13" (330) 7 7/8" (200) 4 1/2" (115) 36 5/8" (930) 40 1/2" (1029) 26 3/8" (670) 15 5/8" (397) 11 13/16" (300) GAS CONNECTION 10 7/8"(R277) 9 13/16" (250) 6 1/2" (165) 6 5/16"(160) 13 3/4" (R3...
SPECIFICATIONS – 6 – MODEL # RHFE-1004FA-P PROPANE BTU/h MIN. CLEARANCES INPUT OUTPUT SIDE TOP LO:203.4 HI:360.6 LO:203.4 HI:360.5 FRONT 2 " (50mm) 10 " (250mm) 40 " (1m) 40 " (1m) FAN CFM OUTPUT 10 " (250mm) 2 " (50mm) Low 10,500 High 38,400 Low 8,400 High 30,700 Low 8,400 H...
SAFETY POINTS – 8 – Do not restrict the warm air discharge byplacing articles in front of the heater. This appliance must not be used for anypurpose other than heating. Do not install the heater in an unusuallydusty area. Do not allow anyone to sit on or lean againstthe appliance. Do not spray aeros...
GETTING TO KNOW YOUR NEW RHFE-1004FA – 10 – CONTROL PANELOPERATION/TEMPERATURECONTROL DISPLAY OPERATION LAMP RATING PLATEMODEL NUMBER,SERIAL NUMBER,GAS TYPE, ETC. WARM AIR OUTLET HUMIDIFIEROPEN THE DOORAND POUR WATERINTO THE TRAY. VENT TERMINALCOMBUSTION/EXHAUST COMBUSTION AIRINTAKE HOSE EXHAUST PIP...
CONTROL PANEL – 11 – Set Temp Room Temp Economy Temp Control Function Lock Filter ON/OFF ON FUNCTION LOCK Lamp is "green" when this feature is on. FILTER LAMP Flashes when filter is dirty. OPERATION LAMP This lamp turns "green" when power is on. Lamp will change to "red" whe...
NOTICE BEFORE INSTALLATION – 13 – The heater must be installed by a qualified serviceperson according to these installation instruction. Check your local building codes for the proper methodof installation. In the case of absence of local codes,this heater should be installed in accordance with theN...
INSTALLATION INSTRUCTIONS – 14 – Check to ensure gas type on rating plate matches gas being supplied to the unit. If not, unit may havebeen converted and should be checked to ensure conversion was done properly. If not, unit could bedamaged due to being overfired.Refer to local gas authority for con...
– 15 – GAS CONNECTION 1. The gas supply line shall be gas-tight, sized and so installed as to provide a supply of gas sufficient to meet the maximum demand of the heater without loss of pressure. 2. A shut off valve (and appliance connector valve) should be installed in the upstream of the gas line ...
– 16 – VENT TERMINATION CLEARANCES INSIDE CORNER DETAIL FIXEDCLOSED OPERABLE FIXEDCLOSED OPERABLE B B B A J B M C F B B E D L G A H K I X AIR SUPPLY INLET V VENT TERMINAL AREA WHERE TERMINAL IS NOT PERMITTED REF DESCRIPTION Canadian Installations U.S. Installations A B CD E F G H I J K L M 1 foot 3 ...
– 17 – LOCATION / CLEARANCES When positioning the heater the main pointsgoverning the location are: 1. Flueing 2. Warm air distribution This heater is not designed to be built in. The flue terminal should be positioned away fromflammable materials. Do not flue into natural draught flues or fireplace...
– 19 – SLEEVE AND MANIFOLD INSTALLATION METHOD FOR STANDARD WALLS 1. Disassemble Manifold from Sleeve. The flue consists of 3 parts, sleeve, inside connectorsand tube, outside terminal; (dis-assembly by pullinghard on outside terminal and inner connections, thenpull sleeve off outer terminal.) 2. Ad...
– 21 – FITTING UNIT 4. Secure with plastic tie as shown below. When servicing unit replace plastic tie with newone.(Available at local hardware store or contactlocal distrilbutor.) 1. Fix Flue Adapter to Flue Manifold with PIPE STOPPER S as shown below. 3. Fit Air inlet Hose to heater. Fix Side Back...
– 24 – ADDITIONAL CUSTOMER OPERATING INFORMATION IGNITION Make certain the heater is connected into both the gasand the electric power.Depress the ignition ON/OFF button slowly and firmly. When you release the ignition ON/OFF button the ‘LED Display will illuminate, the spark will ignite the mainbur...
– 25 – ROOM TEMPERATURE DISPLAY ‘Temperature is indicated by the L.E.D. display on the controlpanel. The first time when the appliance is turned on, the presettemperature ’72 F degrees’(from the factory) will be shown onthe L.E.D.dispIay. Every time the Set Temp has beenchanged,that set temperature ...
– 32 – TROUBLE SHOOTING Your RHFE-1004FA requires very little maintenance, simply clean the rear fan filter as needed and wipethe outer case and louver section with a damp cloth. General maintenance items are not covered under unit's warranty. Such as cleaning dust, debris andcarbon from flame rod, ...
– 33 – ERROR MESSAGES In all cases, you may be able to clear the Error Message simply by turning the heater OFF, then ON again. If the Error Message still remains or returns on the next operation, contact Rinnai or your nearest service agent and arrange for a service call. The Energysaver 1004 has t...
– 34 – MAINTENANCE / SERVICE MAINTENANCE SUGGESTIONS This heater has been designed and constructed fora long performance life when installed and operatedproperly under normal conditions. Regularinspections, as outlined in this section, are stronglyrecommended as means of keeping your heateroperating...
– 36 – Warranty Information Limited Warranty Gas Direct Vent Wall Furnace What is covered? This Warranty covers any defects in materials or workmanship, subject to the terms stated below. This Warranty extends to the original purchaser and subsequent transferees, but only while the product remains a...
– 37 – Limited Warranty - continued What will Rinnai do? Rinnai will repair any part or component that is defective in materials or workmanship as set forth as follows. All repair parts must be genuine Rinnai parts. All repairs or replacements must be performed by an individual or servicing company ...
– 45 – 001 1001F-073 SIDE PANEL 2 1001F-073-4 SIDE PANEL D 2 1001F-073-5 SIDE PANEL E 2 002 1004F-2071 TOP PLATE 1 1004F-2071-3 TOP PLATE C 1 1004F-2071-4 TOP PLATE D 1 003 1004F-2073-2 OPERATION LID B 1 1004F-2073-6 OPERATION LID F 1 1004F-2073-8 OPERATION LID H 1 004 556F-558-2 FULCRUM 1 1 1 005...
– 51 – EXTENSION SET PARTS AND INSTALLATION GUIDE FOT − 102 FOT − 103 FOT − 114 FOT − 115 • This extension set is to be used for installations requiring extra distance. MAXIMUM VENT LENGTH 13 ' WITH 2 ELBOWS ■ NAMES AND NUMBERS OF PARTS A C B A B A B C DEFGHIJKLMN EXHAUST PIPE EXHAUST PIPE EXHAUST P...
– 52 – ■ TYPES COMPATIBLE WITH EXTENSION SET RHFE-1004FAINSTALLING AN EXTENSION KIT Installing an extension kit requires construction of an air line and the exhaust line. The air line is connectedbetween the Air Supply Elbow at the rear of the heater and the air inlet port on the Flue pipe.Similarly...
– 54 – Condensed watermay accumulatehere, and cause a blockagepreventing combustion. ■ CAUTIONS 1. Maximum extendable length FOR BEST ROOM AIR HUMIDITY, KEEP WATERIN THE HUMIDIFIER TRAY. ・ 13 feet, 2 bends ・ The bend where the hose and pipes leave the body isnot counted. ・ The air intake hose should...
– 56 – TECHNICAL DATA GAS CONVERSION SPECIFICATIONS Burner Orifices: ・ The minimum inlet gas supply pressures is for the purpose of input adjustment. ・ Heaters may be converted from one gas to another using Rinnai conversion kits. HI LOW NG PARTS No. 1004F-2031-2-1.80 1004F-2036-2-1.95 QTY' 2 1 LPG ...
Rinnai Manuals
-
Rinnai RCE-329A
User Manual
-
Rinnai RCE-329A
Manual
-
Rinnai RB-167RMF
Manual
-
Rinnai RB-207RMF
Manual
-
Rinnai RB-257RMF
Manual
-
Rinnai RB-307RMF
Manual
-
Rinnai RB-367RMF
Manual
-
Rinnai RB-106GMF/107EMF
Manual
-
Rinnai RB-206GMF/207EMF
Manual
-
Rinnai RB-166GMF/167EMF
Manual
-
Rinnai RB-256GMF/257EMF
Manual
-
Rinnai RB-306GMF/307EMF
Manual
-
Rinnai RB-366GMF/367EMF
Manual
-
Rinnai REH-20D
Manual
-
Rinnai EX11C (RHFE-265FTA)
Manual
-
Rinnai RV53I
Manual
-
Rinnai REU-V2532FFU
Manual
-
Rinnai Q205S
Manual
-
Rinnai RC98I
Manual
-
Rinnai REH-10
Manual