Rinnai REU-VB2528WD-US - Manual
Rinnai REU-VB2528WD-US – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
0.0
1.0
2.0
3.0
4.0
5.0
6.0
7.0
8.0
0
25
50
75
100
125
150
delta T - Temperature Rise (ºF)
Water Flo
w
(gpm)
RL75e (VB2528WD-US)
Type of Appliance
Rinnai Model Number
Minimum/Maximum Gas Rate (Input)
Electrical
Electrical Consumption
Ignition System
Hot Water Capacity
Temperature
Temperature (without remote)
Installation
Energy Factor
Service Connections
Isolation & Pressure Relief Valves Included
Water Flow Control
Minimum/Maximum Water Supply Pressure
•
Temperature controlled, continuous flow, gas hot water system
•
Certified for installation in manufactured (mobile) homes
•
Forced combustion
•
Energy Star qualified
REU-VB2528WD-US
9,900 - 180,000 BTU/h (Natural Gas)
10,300 - 180,000 BTU/h (Propane)
Appliance:
AC 120 Volts - 60 Hz
Controller:
DC
12
Volts
Normal: 44 w Standby: 2 w Anti-frost protection: 104 w
Direct electronic ignition
Minimum flow rate: 0.26 GPM
Minimum activation flow rate: 0.4 GPM
Maximum flow rate: 7.5 GPM
98° - 120° F (factory default) Maximum temperature is selectable at
120° F or at 140° F; 98° - 160° F available with the MCC-91
controller for commercial and hydronic applications
120° F (factory default) or 140° F
Outdoor only
Natural Gas: 0.82
Propane: 0.82
Gas supply: 3/4 inch MNPT
Cold water inlet: 3/4 inch MNPT
Hot water outlet: 3/4 inch MNPT
Heavy duty forged brass Webstone Isolator valves EXP E2, certified
to NSF/ANSI 61-8 for potable water
Water flow sensor, electronic water control device and fixed by-pass
20 - 150 PSI (recommended 30-80 PSI for maximum performance)
© 2011 Rinnai Corporation
RL75e VB SP 1/2011
FLOW TABLE