Rinnai REU-V2520FFUC-US - Manual
Rinnai REU-V2520FFUC-US – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
2520FFUC SP-1
C53i (2520FFUC)
Type of Appliance
Rinnai model number
Operation
Exhaust system
Minimum/Maximum Gas Rate (Input)
Electrical
Electrical Consumption
Ignition System
Hot Water Capacity
Temperature
Temperature (without remote)
Approved Gas Types
Installation
Energy Factor
Thermal Efficiency
Service Connections
Water Flow Control
Minimum/Maximum Water Supply Pressure
Temperature controlled, continuous flow, gas hot water system
REU-V2520FFUC-US
With or without remote controls, mounted in kitchen, bathroom, etc.
Direct vent, forced combustion
15,000 - 180,000 BTU/h (Natural Gas or Propane)
Appliance:
AC 120 Volts - 60 Hz
Remote Control:
DC 12 Volts
Normal
75
watts
Standby 5.5
watts
Anti-frost protection
100 watts
Direct electronic ignition
0.6 to 5.3 GPM (50° F rise)
0.6 to 5.3 GPM (35° F rise)
120° - 185° F
140° F (factory default)
Natural or Propane (ensure unit matches gas type)
Indoor only
Natural Gas: 0.81
Propane: 0.81
Natural Gas: 84%
Propane: 84%
Gas supply: 3/4 inch MNPT
Cold water inlet: 3/4 inch MNPT
Hot water outlet: 3/4 inch MNPT
Water flow sensor, electronic water control device, no bypass
20 - 150 PSI (50 PSI or above is recommended for maximum flow)
2520FFUC SP-1 12/2006
FLOW TABLE
Water Flow Capacity Curves
(For 1 to 5 units manifolded in parallel)
© 2005 Rinnai Corporation
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.