R75LSi (VA2528FFUD)

Type of Appliance

Rinnai Model Number

Operation / Exhaust System

Minimum/Maximum Gas Rate (Input)

Electrical


Electrical Consumption



Ignition System

Hot Water Capacity

Temperature



Temperature (without remote)

Approved Gas Types

Installation

Energy Factor

Thermal Efficiency

Service Connections



Water Flow Control

Minimum/Maximum Water Supply Pressure

Temperature controlled, continuous flow, gas hot water system

REU-VA2528FFUD(A)-UC

Forced combustion / Direct vent

15,000 - 180,000 BTU/h (Natural Gas and Propane)

Appliance:

AC 120 Volts - 60 Hz

Controller:

DC

12

Volts

Normal

65

watts

Standby 2.0

watts

Anti-frost protection

100 watts

Direct electronic ignition

0.6 to 7.5 GPM (35° F rise)

98° - 120° F (factory default) Maximum temperature is selectable at
120° F or at 140° F; 98° - 160° F available with the MCC-91
controller for commercial and hydronic applications

120° F (factory default)

Natural or Propane (ensure unit matches gas type)

Indoor only

Natural Gas: 0.82

Propane: 0.82

Natural Gas: 84%

Propane: 84%

Gas supply: 3/4 inch MNPT
Cold water inlet: 3/4 inch MNPT
Hot water outlet: 3/4 inch MNPT

Water flow sensor, electronic water control device and fixed by-pass

20 - 150 PSI (recommended 30-80 PSI for maximum performance)