Page 2 - RINNAI UK WARRANTY
2 RINNAI UK WARRANTY As the purchaser of this high quality Rinnai Water Heater you are provided with the following conditional guarantee. Definition of Standard Use. The warranty period allocated under Standard Use is based on Domestic and Light Commercial hot water usage. Rinnai Standard Use warran...
Page 3 - CONTENTS
3 CONTENTS Unpacking Rinnai Water Heater.…………………………………………………………… Installation Instructions……………………………………………………………………… Flue Requirements...………………………………………………………………………… Dimensions...………………………………………………………………………………… Technical Details.…………………………………………………………………………… Features and Benefits…………………………………………………...
Page 4 - UNPACKING RINNAI WATER HEATER
4 UNPACKING RINNAI WATER HEATER • After unpacking the appliance check for damage, if the heater is damaged contact your supplier immediately. Do not install a damaged appliance before checking with your supplier. • C • A heater accessories pack is inside the carton. One remote control is supplied wi...
Page 5 - INSTALLATION INSTRUCTIONS
5 IMPORTANT INFORMATION 1. Gas safety (Installation & Use) regulations 1998 are the ‘Rules in force’. In your own interest and that of safety, it is law that all gas appliances are installed by competent persons in accordance with the above regulations. Failure to install appliances correctly co...
Page 6 - INSTALLATION INSTRUCTIONS - POSITIONING
6 General Installation Information. External Installations. The Rinnai Infinity 32e and HD70e are for external mounting only. The unit is classed as a Category A3 flueless appliance as described by CEN CR1749. Although BS 5440 does not relate directly to heaters in this category the rules must be fo...
Page 7 - INSTALLATION INSTRUCTIONS - CONNECTIONS
7 INSTALLATION INSTRUCTIONS - CONNECTIONS Water Supply. Where the water supply pressure exceeds 12 bar, an approved pressure reducing device is required at the inlet of the appliance. To achieve the rated flow a minimum water supply pressure of 1.4 bar is required at the appliance inlet. The unit wi...
Page 8 - FLUE REQUIREMENTS - POSITIONING
8 Dime J L H H K F I nsion Terminal Position Distance A Directly below an opening, air brick, opening windows, etc. 300mm B Above an opening, air brick , opening window, etc. 300mm C Horizontally to an opening, air brick , opening window, etc. 300mm D Below gutters, soil pipes or drain pipes. 75mm E...
Page 9 - DIMENSIONS
Page 10 - TECHNICAL DETAILS
10 TECHNICAL DETAILS Infinity Model Infinity 32e HD70e Units Installation External External Nat Gas Press Low 1.8 1.8 mbar Nat Gas Press High 7.4 7.4 mbar LPG Press Low 3.5 3.5 mbar LPG Press High 17.6 17.6 mbar Height 600 600 mm Width 470 470 mm Depth 244 220 mm Weight 29 29 kg Flue System Temp. Ra...
Page 11 - FEATURES AND BENEFITS
11 Congratulations on purchasing the Technologically Advanced, Temperature Controlled,Rinnai Hot Water System. • The Rinnai Infinity 32e and HD70e NEVER RUN OUT of hot water. As long as electricity, water, and gas supplies are connected, hot water is available when hot water taps are open. • Built i...
Page 12 - DO
12 Excessively hot water is dangerous, especially for young children and the infirm. Thewater heater allows you to control the temperature of your hot water to safe levels. Do stay with children whenever they are in the bathroom. Do take them out of the bathroom ifyou need to answer the phone ordoor...
Page 15 - TEMPERATURE CONTROLS - GENERAL
15 TEMPERATURE CONTROLS - GENERAL When deciding on the best position for the temperature controls, the following points should be taken into account. • Fit the controls out of reach of children (suggested height from the floor 1.5m.) • Avoid positions where the controllers will become hot. Do not fi...
Page 16 - TEMPERATURE CONTROLS - INSTALLATION
16 TEMPERATURE CONTROLS - INSTALLATION Universal Temperature Controller MC-91-1A 1. Determine the most suitable position for the temperature controller. 2. Drill 3 holes in the wall as shown in fig.1, one for the cable and two for the securing screws. Ensure holes are drilled deep enough. Fit wall p...
Page 18 - TEMPERATURE CONTROLS
18 TEMPERATURE CONTROLS The purpose of a Temperature Controller is to enable the user to have complete control over the hot water supply. Used correctly, the hot water unit will supply hot water at the temperature selected, even when the water flow is varied, or when more than one tap is used. Adjus...
Page 19 - TEMPERATURE CONTROLS - OPERATING
19 Remote temperature controllers are a feature that provides control over the water temperature. Rinnai Infinity and HD water heaters can be operated with 1, 2, 3, 4 or no temperature controllers. The Universal controller MC-91-1A comes as standard with all Infinity water heaters. NOTE: Each time a...
Page 20 - Using 1 Universal Temperature Controller.
20 TEMPERATURE CONTROLS - OPERATING Using 1 Universal Temperature Controller. Press the On/Off button on the temperature controller. The ON indicator will glow on the TemperatureThis indicates that the heater is ready to supplywhen a tap is opened. To operate the heater, simply turn any hot water ta...
Page 21 - Using 2 or more Universal Temperature Controllers.
21 Using 2 or more Universal Temperature Controllers. Switching the system ON. Using hot water. Bathroom temperatures should be no more than 50 0 C. The hot water system and all controllers can be switched ON and OFF from any controller by pressing the On/Off button as shown. When the system is turn...
Page 23 - Using High Temperature Display Controllers.
23 Using High Temperature Display Controllers. You will need to program the Master controller if you want to display and use temperatures over 50 0 C. Programming only needs to be done on Master universal controllers; other universal controllers will not allow this, and Deluxe Kitchen Controllers ar...
Page 24 - Note; To turn off your hot water system.
24 Note To turn off your hot water system. Additional safety features. During normal operation the system is left on. To turn the system off simply press the On/Off button on any temperature controller (where fitted). This will shut the water heater down completely including the temperature controll...
Page 25 - TEMPERATURE CONTROLS - INFORMATION
25 TEMPERATURE CONTROLS - INFORMATION Do not push the On/Off button on the Master controller after transferring priority of temperature selection to a Secondary controller as the system will shut down. Do Not Turn OFF the Master Controller Temperature priority can not be switched to another controll...
Page 26 - TESTING; C A U T I O N
26 TESTING 1. Purge gas, hot water and cold water supply lines before making the final connection of the water heater. Swarf in either the gas or water supplies may cause damage. 2. Turn on gas and cold water supplies. 3. Test for water leaks and gas escapes near the unit. 4. Isolate gas and electri...
Page 27 - GAS PRESSURE SETTING; Contact Rinnai UK before
27 GAS PRESSURE SETTING The working gas pressure on the water heater is electronically controlled and factory set. Under normal circumstances it does not require adjustment during installation. Perform this procedure only if the unit is not operating correctly and all other possible causes for incor...
Page 29 - DIP SWITCH SETTING
29 DIP SWITCH SETTING Dip Switch Positions Explained OFF ON SW2 1 - Gas Type LEGEND: 2 - Gas Type Black Section indicates 3 - Temperature position of dip switch. 4 - Temperature 5 - Temperature OFF OFF 6 - Temperature OFF ON SW3 OFF ON 1 - Computer Programming 2 - Combustion 3 - Combustion Dip Swich...
Page 31 - ERROR MESSAGES
31 ERROR MESSAGES Rinnai water heaters have the ability to check their own operation continuously. If a fault occurs, an error code will flash on the Digital Display if you have temperature controllers installed. This assists with diagnosing the fault, and may enable you to overcome a problem withou...
Page 32 - Troubleshooting without controllers; Installations with circulation pumps
32 ERROR MESSAGES Troubleshooting without controllers If you have not installed temperature controllers and experience the following symptoms, please carry out the suggestions below. If symptoms continue, please contact Rinnai for advice. NOTE: Faults caused by insufficient gas/water supply or gas/w...
Page 33 - RESTARTING THE RINNAI WATER HEATER; Hot water system incorporating secondary recirculation pump.
33 RESTARTING THE RINNAI WATER HEATER Following a power cut the heaters should be restarted in this manner. Standard system. Single or multiple water heaters without remote controllers. The heaters will automatically reset without any user involvement. Single or multiple water heaters with remote co...
Page 34 - WIRING DIAGRAM
Page 35 - DIAGNOSTIC POINTS; TRANSFORMER
35 DIAGNOSTIC POINTS Diagnostic Points- To be read in conjunction with the wiring diagram. COMPONENT SURGE PROTECTOR WATER FLOWCONTROL DEVICE BY-PASS FLOWCONTROL DEVICE REMOTE CONTROL WATER FLOW SENSOR COMBUSTION FAN FLAME ROD MODULATING VALVE OUTGOING THERMISTORHEAT EXCHANGEROUTGOING THERMISTOR THE...
Page 36 - SPECIFICATION
36 SPECIFICATION Model ………………………………………………..…....………..... Infinity 32e and HD70e Installation …………………………………………...………...……. External location only Fuel …………………………………………………..….……………... Natural Gas or LPG * Control ………………………………………………….……………...……….….. Modulating Input ……………………………………………………..……….……………........
Page 37 - NOTES
Page 38 - SERVICE CONTACT
38 SERVICE CONTACT UK LTD. 9 Christleton Court Manor Park Runcorn Cheshire WA7 1ST Tel. 01928 531870 Fax. 01928 531880 E-mail. [email protected] Web. www.rinnaiuk.com
Page 39 - COMMISSIONING CHECK LIST
39 COMMISSIONING CHECK LIST For full details - Refer to Installation Instructions Gas supply pipe is purged of foreign matter before connection. For Hot and Cold cross connections i.e. Capped breaches/shower mixers,taps closed and reversed ‘Flick Mixer’ connections? That isolating valves are not con...