Page 2 - This page is intentionally blank
Rinnai 2 HW_CF OIM This page is intentionally blank
Page 3 - OPERATION TABLE OF CONTENTS; Warnings & Important Information; Notice to Victorian Consumers ������������������������������������������������������������������������������������������������������������������������������������������ 4; Water Temperature Control; Water Controller Combinations & Configurations; Wired Only Configurations; Trouble Shooting; No power display Wireless Water Controller (when fitted); Installation Table of Contents
Rinnai 3 HW_CF OIM OPERATION TABLE OF CONTENTS Warnings & Important Information 4 Regulatory Information ������������������������������������������������������������������������������������������������������������������������������������������������������� 4 Notice to Victorian Consumers �������...
Page 4 - REGULATORY INFORMATION; WARNINGS & IMPORTANT INFORMATION
Rinnai 4 HW_CF OIM REGULATORY INFORMATION Your Rinnai Continuous Flow water heater has been certified by the Australian Gas Association. The A.G.A. Certification Number is shown on the data plate. This Appliance must be installed correctly by an authorised person� The installation of gas, water, and...
Page 5 - Operational Safety Information; To clean your water controller(s) use a soft damp cloth; temperatures displayed at the water controller(s) and; DO NOT; having a shower or filling a bath.
Rinnai 5 HW_CF OIM Operational Safety Information IMPORTANT This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the ...
Page 6 - similarly qualified persons in order to avoid a hazard.
Rinnai 6 HW_CF OIM IMPORTANT The range of Rinnai continuous flow water heaters referred to in this manual are incompatible with solar water heating systems. A dedicated range of solar compatible continuous flow water heaters is available from Rinnai� If the supply cord is damaged, it must be replace...
Page 7 - Up to four water controllers can be fitted. See page 9 for details.; Infinity 26 Touch
Rinnai 7 HW_CF OIM FEATURES & BENEFITS Congratulations on purchasing the latest technology temperature controlled Rinnai continuous flow water heating system� • The Rinnai Continuous Flow water heater products NEVER RUN OUT of hot water� Whilst electricity, water and gas supplies are connected, ...
Page 8 - MAXIMUM DELIVERY TEMPERATURES; as a licensed plumber�; OPERATION WITHOUT WATER CONTROLLERS; controllers that can be fitted to your water heater model.; Location; outside of the shower recess�; WATER TEMPERATURE CONTROL
Rinnai 8 HW_CF OIM MAXIMUM DELIVERY TEMPERATURES Rinnai continuous flow water heaters are factory pre-set to various maximum delivery temperatures depending on model and their intended application� For the majority of applications, the factory pre-set temperature is appropriate�In the unlikely event...
Page 9 - Temperature Control; WATER CONTROLLER COMBINATIONS & CONFIGURATIONS
Rinnai 9 HW_CF OIM Temperature Control Water controllers allow precise temperature control by the user� When used correctly, the hot water unit will deliver the selected temperature, even when the water flow is varied, or more than one tap is in use. Only one MC model water controller can be designa...
Page 10 - required temperature is displayed on the digital monitor.; MUST NOT; MUST; of priority will; NOT; to supply hot water once a hot water tap is opened�
Rinnai 10 HW_CF OIM UNIVERSAL WATER CONTROLLER (MC-601Q) OPERATION Turning On If the water controller is switched off (No digits displayed in the digital monitor window) press the On/Off button once� The ON indicator will illuminate, indicating that the hot water unit will be ready to supply hot wat...
Page 11 - until the required temperature is; installation configuration.; Indicates that Smartstart; Used to start and stop; PREHEAT
Rinnai 11 HW_CF OIM SMARTSTART PRE-HEAT SYSTEM The “Preheat” function works in conjunction with various Rinnai water heater models when the separately installed and optional Rinnai “Smartstart®” module is installed� Preheat Function When the “Preheat” function is activated and used in accordance wit...
Page 12 - ERROR CODES; TROUBLE SHOOTING
Rinnai 12 HW_CF OIM ERROR CODES Your Rinnai Continuous Flow water heaters has a self diagnostic capability� If a fault occurs, an Error Code will flash on the digital monitor of your water controllers or on the status monitor * on the front cover of the water heater. This assists with diagnosing the...
Page 13 - installation errors or operation errors are; located on the left hand side of the appliance�
Rinnai 13 HW_CF OIM No power display Wireless Water Controller (when fitted) When power to the water heater is disconnected the LCD of all wireless water controllers will display as shown to the right� Check that the power is available, and that the water heater is plugged in with the power point tu...
Page 14 - Installation Configurations; Water Controller Installation; Additional Programming & Activation Requirements; Commissioning 24; INSTALLATION TABLE OF CONTENTS
Rinnai 14 HW_CF OIM Operation Table of Contents 3 General Installation Information 15 Regulations ������������������������������������������������������������������������������������������������������������������������������������������������������������������������ 15 Applicable Models ������������...
Page 15 - Location of the appliance flue terminal; Mounting Of Appliance; GENERAL INSTALLATION INFORMATION
Rinnai 15 HW_CF OIM NOTE INSTALLATION, SERVICE AND REMOVAL MUST BE BY AN AUTHORISED PERSON ONLY � It is the installer’s responsibility to ensure all current AS/NZS 5601 requirements are met�Remove transit protection� Check for damage, if any is found DO NOT install and contact supplier� REGULATIONS ...
Page 16 - fitted to the cold water and gas inlets.; be fitted directly to the appliance.; Pipe Sizing; regulator; MUST BE; specified for this gas rate.; Water Supply; in Table 2 must be supplied�
Rinnai 16 HW_CF OIM Service Connection Points Refer to "Table 2. Supply, Flow rates, Weights & Flow & Service Connections" on page 27 for model specific connection / fitting dimension details.An Approved full flow isolation valve and disconnection union MUST BE fitted to the cold wat...
Page 17 - HOT WATER DELIVERY TEMPERATURE; Local regulations and or the requirements of AS/NZS 3500; Diagram 1 : 50°C Appliance; a 50°C Appliance
Rinnai 17 HW_CF OIM HOT WATER DELIVERY TEMPERATURE Local regulations and or the requirements of AS/NZS 3500 MUST BE addressed regarding the temperature limitations of hot water supplied to areas used primarily for personal hygiene� The temperature of water to these areas may be limited to 50°C or le...
Page 18 - APPLIANCE FLUE TERMINAL; FLUEING
Rinnai 18 HW_CF OIM APPLIANCE FLUE TERMINAL Horizontal Terminal Clearances (Extract from AS/NZS 5601) Min� Clearances (mm) For appliances up to 50 MJ/h input 200 For appliances over 50 MJ/h input 300 300 * e c a fr u s r e h t o r o y n o cl a b a e v o b a , d n u o r g e h t m o r F b 300 * r e n ...
Page 19 - Horizontal Obstructions; Sideways Flue Diverter; When a Sideways Flue Diverter is to be fitted the installer; When a Sideways Flue Diverter is fitted; from AS/NZS 5601) dimension ‘h’ on page 18 does; Factory Default
Rinnai 19 HW_CF OIM Horizontal Obstructions AS/NZS 5601 ‘Gas Installations’ stipulates a minimum horizontal clearance of 500 mm between a building structure and obstruction facing the terminal� For correct operation of Rinnai external continuous flow water heaters such a building structure MUST ‘obs...
Page 20 - GENERAL INFORMATION; ONLY; A maximum of 4 water controllers can be fitted.; WATER CONTROLLER INSTALLATION
Rinnai 20 HW_CF OIM GENERAL INFORMATION IMPORTANT Other manufacturers water controllers are NOT compatible with Rinnai water heaters� Water controllers MUST NOT be used with any Solar Boost water heater� Rinnai water controllers brought in from other countries are not compatible with Rinnai applianc...
Page 21 - be installed where chemicals such as benzene, alcohol,; Rinnai supplied
Rinnai 21 HW_CF OIM Location NOTE • DO NOT install water controllers near a heat source, such as a cook top, stove or oven� Heat, steam, smoke and hot oil may cause damage� • DO NOT install water controllers outdoors unless protection from water / dust ingress and sunlight are provided� • The water ...
Page 22 - shown allowing sufficient cable length so that
Rinnai 22 HW_CF OIM Communication Cable(s) & ’Ezi connect’ CAUTION DO NOT attempt to connect cables to the 'Ezi connect' cable connector at the water heater unless the electric power to the water heater is switched ‘off’ otherwise damage to electrical components may occur� If your water heater i...
Page 23 - Are there four water controllers connected?; You will need to activate the fourth water controller as follows:; temperatures higher than 50°C�; water controller fitted in a bathroom), repeat
Rinnai 23 HW_CF OIM Additional Programming & Activation Requirements QUESTION ? 1 Are there four water controllers connected? IF NO: You have three (or fewer) water controllers, go to Question 2. IF YES: You will need to activate the fourth water controller as follows: STEP 1: For the water cont...
Page 24 - TESTING; for details�; If water controllers are not fitted, simply open; ALL; Ensure building occupants; circumstances it; to deliver a maximum temperature not exceeding 50°C. For fine; For All Other Models; COMMISSIONING
Rinnai 24 HW_CF OIM TESTING 1� Before final connection of the water heater purge gas, hot water and cold water supply lines. Debris or swarf in either the gas or water supplies may cause damage� 2� Turn on gas and cold water supplies� 3� Test for water leaks and gas escapes near the unit�4� Isolate ...
Page 25 - DOES NOT; require; hand side of the water heater�
Rinnai 25 HW_CF OIM GAS PRESSURE SETTING The regulator is electronically controlled and factory pre-set� Under normal circumstances it DOES NOT require adjustment during installation� Make adjustments ONLY if the unit is not operating correctly and all other possible causes for incorrect operation h...
Page 26 - TABLE 1. APPLIANCE DIMENSIONS; Touch; DIAGRAM 1. DIMENSIONS; Infinity Series; SPECIFICATIONS
Rinnai 26 HW_CF OIM TABLE 1. APPLIANCE DIMENSIONS Use this table in conjunction with "Diagram 1. Dimensions" below. All dimensions in mm unless otherwise stated. Model REU-AM1220WD Infinity 12 REU-AM1620WD Infinity 16 REU-AM2024WD Infinity 20 REU-AM2626WD Infinity 26 REU-AM2626WDL Infinity 2...
Page 27 - TABLE 3. MAXIMUM DELIVERY TEMPERATURES; Delivery; TABLE 4. OTHER ACCESSORIES; CAGE
Rinnai 27 HW_CF OIM TABLE 2. SUPPLY, FLOW RATES, WEIGHTS & FLOW & SERVICE CONNECTIONS Model Gas Rate Water Supply Pressure Max Flow at Temp Rise (at minimum water supply pressure) W eight Fittings Min Max Hot Cold Gas MJ/hr kPa L/min / °C kg (DN = mm) REU-AM1220WD - Infinity 12 92 120 1000 1...
Page 28 - Rinnai Australia Pty Ltd
Rinnai Australia Pty Ltd ABN 74 005 138 769 100 Atlantic Drive, Keysborough, Victoria 3173P.O. Box 460, Braeside, Victoria 3195Tel: (03) 9271 6625 Fax: (03) 9271 6622 U340-1330(0 1 ) 28 HW_CF OIM Issue 1 - Oct 2017