Page 2 - Experience our Innovation; About this Brochure; CONTENTS; CONTINUOUS FLOW
Experience our Innovation For over 35 years Australians have been enjoying the comfort, convenience and reliability of Rinnai gas appliances. Our innovative products are designed with the environment in mind, with low emission technology and high efficiencies, as well as a host of other great featur...
Page 4 - Range Overview – Hot Water; Gas Continuous Flow; Solar Systems
04 Range O ver vie w Hot W at er Range Overview – Hot Water Rinnai has an extensive range of hot water systems that cater for both domestic & commercial applications. Each range has specific and unique benefits which are explained both below and throughout this brochure. Gas Continuous Flow • On...
Page 6 - Continuous Flow Hot Water; Range at a glance; Selection Guide & Sizing
06 Con tinuous F lo w R ange a t a glanc e Continuous Flow Hot Water Range at a glance Rinnai has the largest range of Continuous Flow water heaters in Australia today. As the company that developed the Continuous Flow market, we now have 5 dedicated ranges designed for specific applications. The ta...
Page 7 - Is it an Internal or External Installation?; Hot Water Delivery Temperature; Preset 55°C Appliances; Rinnai Preset 50; the serial number of the appliance.
07 Hot W at er Deliv er y Temper atur e 3. The type of shower roses installed? Most States and Territories have legislation where new homes must have a minimum of 3 Star rated (9 litre/min) shower roses installed. Many older homes however, still have higher flow rated showers. HANDY HINT We recommen...
Page 8 - Water Controllers; Why install Water Controllers?; Universal Wireless Controllers:; Deluxe functions include:
08 W at er C on tr ollers Water Controllers Why install Water Controllers? Rinnai strongly recommend installing Controllers to allow you to take full advantage of all the benefits available. Water Controllers depending on the model selected, enable the following additional benefits with any Continuo...
Page 9 - Internal Flueing; Vertical Direct Flueing; Horizontal Direct Flueing; Horizontal Extended Flueing; Flue Components; Dimensions in mm
09 In ternal F lueing Internal Flueing Rinnai offer the only 26 litre internal units available on the market. The Rinnai INFINITY 26i domestic unit and the HD200i commercial model. Ideal for replacement of existing internal hot water systems or simply used when limited space is available externally ...
Page 10 - Combination Flueing
10 In ternal F lueing Vertical Direct Flueing This is the most common system sold with flueing directly above the unit penetrating the roof line in a single storey home. The following components will be required in these combination:• Vertical Flue Terminal with roof cowl• Additional Flue lengths (i...
Page 12 - Continuous Flow Technical Information; Flow Rate Characteristics; Cold Water + Temperature Rise = Outlet Temperature
13 Technical I nf orma tion Continuous Flow Technical Information Flow Rate Characteristics In response to market trends and as part of our continuous improvement processes, Rinnai have developed new technologies and are introducing a number of modifications that allow our continuous flow models to ...
Page 13 - Continuous Flow Specifications
13 Specifica tions Model REUV- 16 20 W G A K 16 20 W BA K 16 20 W S( 60 A K 20 24 W G A K 24 26 W BA K 24 26 W S( 60 )A K 24 30 W K 26 26 W G -A K 26 30 W D A K 26 32 W C( 65 )A K 26 32 FF U G A 2 63 2F FU C( 65 ) A 32 37 W G A K 32 37 W C( 65 )A K Model Name INF16 V1200 S20 INF20 V1500 S26 Enviro- ...
Page 14 - Recess Boxes; Smartbox®; Continuous Flow Accessories
14 A cc essories Rinnai offer a comprehensive range of accessories that assist with the installation of Continuous Flow models. Recess Boxes When installing a Rinnai Continuous Flow unit in a new home or renovation, you should consider using a recess box. These boxes allow you to virtually hide the ...
Page 15 - New Homes or Extensions
15 A cc essories RBOX02 (Galvanised Recess Box) The RBOX02 recess Box is for use with the larger INFINITY 32, HD200e & HD250e Continuous Flow water heaters and is suitable for brick constructions only. The RBOX02 requires an available cavity depth of 230mm and is usually installed as follows: Ne...
Page 16 - Smartstart® Water Saver; Operation overview
16 A cc essories Smartstart® Water Saver The Rinnai Smartstart® water saver has been developed to specifically reduce water wastage whenever a hot tap is turned on.• Allows user to pre-heat the water in the pipes before the tap is turned on • Simply activated by the ‘preheat’ button on any Rinnai Wa...
Page 17 - Pipe Covers; Security Bracket; Sideways Flue Diverter; Conditions & Clearances
17 A cc essories Pipe Covers Pipe Covers can be easily attached to most Rinnai Continuous Flow Hot Water units to: • Cover the pipes, valves and even the external power point• Provides a clean and smooth finish to the installation• Two pipe covers can be joined together to hide longer pipe work unde...
Page 18 - Close Coupled Systems; Rinnai Solar Hot Water Systems; Split Systems
18 Solar Range at a glanc e Range at a glance Close Coupled Systems Where the Storage Cylinder and the Solar Collectors (panels) are coupled together and the installation is on the roof. A choice of an electric boost element in the cylinder or a gas booster installed usually on the side of the house...
Page 19 - Rinnai Prestige
19 Solar R ange a t a glanc e The Rinnai Solar Hot water Systems are separated into 2 ranges: Rinnai Prestige • Highest quality Stainless Steel cylinders • Supplied with high efficiency Excelsior Solar Collectors• Available in both Close Coupled and Split Systems• Available in both Gas or Electric B...
Page 20 - How to claim the RECs rebate?; Solar Rebates
20 Solar R eba tes How to claim the RECs rebate? Ultimately the RECs awarded to any system are traded/sold on the open market at a price which fluctuates according to supply and demand.The simplest way is to fill out the REC rebate declaration form that is supplied with each system which transfers t...
Page 21 - RECs and Rinnai Solar Systems
21 RECs and R innai S olar S yst ems Rinnai Prestige RECs Zones (Excelsior) Description Size Booster Collectors 1 2 3 4 Split System Gas System A 160L S20 1 27 27 27 23 System B 250L S20 2 42 44 42 35 System C 250L S26 2 42 44 42 35 System D 315L S26 2 42 44 42 36 System E 315L S26 3 48 48 48 42 Spl...
Page 22 - Sizing; Correct Sizing; Number of Occupants; Tips on selecting the best Rinnai System; What Solar Zone is applicable for the installation?
22 Sizing Correct Sizing Correct Sizing is vital for optimum performance Number of Occupants The number of users in any installation is extremely important as it directly affects the size of unit that is required. Nobody likes a cold shower so it is vital that any system is correctly sized for an ap...
Page 23 - Rinnai Solar System Sizing Tables
23 Sizing Rinnai Solar System Sizing Tables Vitreous Enamel Split Systems - Gas Solar Zone(s) Number of Bedrooms System Performance Tank Storage Capacity (Litres) No of Solar Collectors Booster Size Rinnai Sunmaster System 1, 2 & 3 1 to 3 Good 175 1 S20 1 Best S26 2 2 to 3 Good 175 1 S26 2 Best ...
Page 24 - Ordering Sunmaster Solar
24 Odr ering Stainless Steel Split Systems - Electric Solar Zone(s) Number of Bedrooms Tank Storage Capacity (Litres) No of Solar Collectors Booster Size Rinnai Prestige System 1, 2 & 3 1 to 3 250 2 3.6kW F 3 to 4 315 2 3.6kW G 3+ 315 3 3.6kW H 4 1 to 2 250 2 3.6kW F 2 to 3 315 2 3.6kW G 3+ 315 ...
Page 25 - Rough I; Solar Rough in Diagram; Sunmaster Split Systems
25 Rough I n Sunmaster Split Systems- Enamel Tanks 175 Lt Gas Boost 160 Lt Electric Boost 215 Lt Gas Boost 200 Lt Electric Boost 270Lt Gas Boost 315Lt Electric Boost A Collector Width 1015 1015 1015 1015 B Width of two collectors 2100 2100 2100 2100 C Length of Solar collectors 1930 1930 1930 1930 H...
Page 26 - Prestige Systems; Prestige Close Coupled
26 Rough I n Split Systems Stainless Steel Electric Boost Gas Boost Close CoupledStainless Steel Gas & Electric 160 Lt 250 Lt 315 Lt 160 Lt 250 Lt 315 Lt 180 Lt 330 Lt A Collector Width 1015 1015 A Collector Width 1015 B Width of two collectors 2100 2100 B Width of two collectors 2100 C Length o...
Page 27 - Solar Collector Dimensions; Solar Collector Installation; Standard “Pitch Roof ” installation – Split System Collectors
27 Solar C ollec tors Solar Collector Dimensions Characteristics Enduro Equinox Frost Tolerant Excelsior Excelsior Frost Tolerant Enduro SP152 Code SP200A SP200A FTC EXT EXT FTC SP152 Type Flat Plate Construction Waterways Copper Absorber Aluminium Aluminium Copper Copper Aluminium Selective Surface...
Page 28 - Rinnai Centurion; Rinnai HOTFLO; Gravity Feed Systems; Rinnai Roofmaster; Electric Hot Water Systems
28 Elec tric R ange a t a glanc e Range at a glance Mains Pressure Systems Rinnai has two mains pressure ranges of Electric Hot Water – Centurion & HOTFLO. They are simply a storage cylinder that holds water at a pre-set temperature with the use of thermostatic control. As hot water is used, it ...
Page 29 - Range Overview; Solar Boosted Roofmaster; Roofmaster Prestige
29 Elec tric R ange O ver vie w Range Overview The table below outlines the sizes and element option for all Rinnai Electric Hot Water Systems Range Size Construction Heating Element Size Twin Element Option 1.8kW 2.4kW 3.6kW 4.8kW Centurion 160 Litres Stainless Steel 250 Litres Stainless Steel 315 ...
Page 30 - Selecting the correct Electric system; Step 3 - Number of persons; Electric Storage Recovery Times; Element size
30 Sy st em S elec tion Selecting the correct Electric system Step 1 - Tariff • Determine which tariff that is going to be used• If using both Peak & Off-peak use the sizing guide for Off-peak Step 2 - Climate • Refer to the Climate Map on page 7 to reference whether the installation is in a war...
Page 31 - HOTFLO and Centurion; Specifications; Roofmaster
31 Specifica tions Specifications Hotflo Centurion Rated Capacity (Litres) 40 80 125 160 200 250 315 400 160 250 315 Weight Empty (kg) 24 48 62 75 98 107 117 39 49 59 Heating Elements Available (kW) - - - - - - - 1.8 1.8 1.8 2.4 2.4 2.4 2.4 - - - 2.4 2.4 2.4 3.6 3.6 3.6 3.6 3.6 3.6 3.6 3.6 3.6 3.6 3...
Page 32 - Commercial Hot Water Systems; Rinnai Manifold Packs
32 Commer cial Commercial Hot Water Systems Rinnai Manifold Packs A Rinnai Manifold Pack consists of 2 to 6 Heavy Duty continuous flow water heaters plumbed together to allow higher flow rates than a single unit can provide. The Rinnai Heavy Duty (HD) water heaters are suitable for single installati...
Page 33 - Rinnai Demand Duo Systems; For further information or on site assistance please contact our
33 Commer cial Rinnai Demand Duo Systems Rinnai Demand Duo is the combination of between 1 to 6 gas Continuous Flow water heaters with single or multiple storage cylinders. The storage cylinder allows a short period of high hot water flow rate, greater than the continuous flow rate of the HD water h...
Page 34 - Warranty; Continuous Flow Systems; Rinnai Service; Need help with an installation?
34 Ser vic e and W arr an ty Solar Hot Water Systems Hotflo Electric Hot Water Systems Solar Electric Solar Compatible Continuous Flow Water Heaters - models S20 and S26 and other models converted by Rinnai for Solar applications (1) (3) Storage Cylinders Solar Collectors Components (2) Cylin- der C...
Page 35 - Rinnai “Domestic Use warranty periods apply to:
Commercial and Other Hot Water Systems Commercial and Other Hot Water Systems Rinnai Demand Duo and Rinnai Manifold Pack systems Other Hot Water Continuous Flow Water Heaters used as gas boosters in Demand Duo and Manifold Pack Systems - Heavy Duty (HD) Models (1) S/Steel storage cylinders Component...
Page 36 - RINNAI AUSTRALIA PTY. LTD
RINNAI AUSTRALIA PTY. LTD ABN 74 005 138 769 10-11 Walker Street Braeside VIC 3195 For further information visit www.rinnai.com.au or call 1300 555 545 68.09_MAY At Rinnai Australia we are committed to on going innovation to deliver efficient, well engineered and designed products. We aim to offer a...