Page 2 - WELCOME
REMINGTON QFP40 Direct Vent FIREPLACE Page 2 250-4721 JUNE 2001 Aladdin Hearth Products welcomes you to our tradition of excellence! In choosing a Quadra- Fire appliance, you have our assurance of commitment to quality, durability, and performance. This commitment begins with our research of the mar...
Page 3 - NOTES
Page 3 REMINGTON QFP40 Direct Vent FIREPLACE 250-4721 JUNE 2001 MODEL NAME Quadra Fire REMINGTON QFP40 SERIAL NUMBER Located on front, lower ledge of control panel. DATE PURCHASED DEALERSHIP WHERE PURCHASED DEALER PHONE ADDITIONAL INFORMATION After completing your warranty card, attach your sales re...
Page 4 - CONTENTS
REMINGTON QFP40 Direct Vent FIREPLACE Page 4 250-4721 JUNE 2001 CONTENTS CONTENTS SAFETY & CLEARANCES: Ratings Plate ................................................................................................. 6Standards Listing & Clearances Label ..........................................
Page 6 - SAFETY; RATINGS PLATE
REMINGTON QFP40 Direct Vent FIREPLACE Page 6 250-4721 JUNE 2001 1999 2000 2001 JAN FEB MAR MAY JUN JUL AUG SEP OCT NOV DEC SAFETY LABEL Location: Serial No. portion on lip below control panel. Lower portion behind access door onbaseplate to right of control panel. 1445 N. Highway Colville, WA 99114 ...
Page 7 - STANDARDS/CLEARANCES LABEL
Page 7 REMINGTON QFP40 Direct Vent FIREPLACE 250-4721 JUNE 2001 Install fireplace in accordance with all local codes, if any; if none, follow The National Fuel Gas Codes ANSI Z223.1-1992 and NFPA 54(88); or Canadian Installation Codes CAN/CGA-B149. Manufactured or Mobile Home Installation This appli...
Page 9 - SAFETY NOTICES
Page 9 REMINGTON QFP40 Direct Vent FIREPLACE 250-4721 JUNE 2001 SAFETY NOTICES IF YOU SMELL GAS! ☛ Do not light any appliance ☛ Extinguish any open flame ☛ Do not touch any electrical switch or plug or unplug anything ☛ Open windows and vacate building ☛ Call gas supplier from neighbor’s house, if n...
Page 10 - HEATING SPECIFICATIONS; SPECIFICA
REMINGTON QFP40 Direct Vent FIREPLACE Page 10 250-4721 JUNE 2001 ZC APPLIANCE DIMENSIONS 29 1/16" 41" 45 4" 7" 1" Gas Inlet - 1 1/4" above base of unit, accessiblefrom either side. ElectricalConnection Nail Down Plate 37 1/8" 1/2" Stand-offs (3 per side) 32 1/32" ...
Page 11 - MINIMUM CABINET DIMENSIONS
Page 11 REMINGTON QFP40 Direct Vent FIREPLACE 250-4721 JUNE 2001 SPECIFICA TIONS MINIMUM CABINET DIMENSIONS Width 54 9/16" Depth 20 1/2" Height 56 1/2" Minimum1/2" trim. Maximum mantel depth is12" The following minimum cabinet dimensions are the minimal allowances for clearance t...
Page 12 - INSTALLATION TERMINOLOGY; PREP
REMINGTON QFP40 Direct Vent FIREPLACE Page 12 250-4721 JUNE 2001 Access Door Mantel Fascia Framing Simpson-DuraVentVenting ZCAppliance Combustible Wall(See Clearances, Page 7) Gas line Electricalline HorizontalTermination Cap INSTALLATION TERMINOLOGY DuraRock,Tile, etc. Stand-offs Glass Header PREP ...
Page 13 - AN OVERVIEW: INSTALLATION TO OPERATION; PREPARATION
Page 13 REMINGTON QFP40 Direct Vent FIREPLACE 250-4721 JUNE 2001 AN OVERVIEW: INSTALLATION TO OPERATION 1. Remove door by releasing four spring clips (2 upper and 2 lower). See Pg. 53. 2. Remove logset, lava rock, embers and packaging materials from firebox. 3. Familiarize yourself with this manual....
Page 14 - LP CONVERSION INSTRUCTIONS
REMINGTON QFP40 Direct Vent FIREPLACE Page 14 250-4721 JUNE 2001 NOTE: If converting this unit to propane, do so at this point of installation. LP CONVERSION INSTRUCTIONS Part # 842-4470 is required for this procedure. CAUTION: DISCONNECT ANY ELECTRICAL CORDS AND TURN OFFGAS SUPPLY TO UNIT BEFORE PR...
Page 16 - INST; MINIMUM FRAMING DIMENSIONS
REMINGTON QFP40 Direct Vent FIREPLACE Page 16 250-4721 JUNE 2001 INST ALLA TION MINIMUM FRAMING DIMENSIONS ❖ The 1/2" stand-offs on the back and sides and 4" stand-offs on the top of the fireplace separate the fireplace from the framing members (see page 12,Installation Terminology). These s...
Page 17 - CORNER INSTALLATIONS
Page 17 REMINGTON QFP40 Direct Vent FIREPLACE 250-4721 JUNE 2001 INST ALLA TION CORNER INSTALLATIONS The usual 45º installation uses the minimum framing dimensions shown in the illustrationbelow. PLEASE NOTE: All clearances as referenced on page 7 still apply. 13 13/16" 45 3/16" 12 1/16"...
Page 18 - RAISED FIREPLACE
REMINGTON QFP40 Direct Vent FIREPLACE Page 18 250-4721 JUNE 2001 INST ALLA TION RAISED FIREPLACE The fireplace and it’s hearth, if desired, may be placed on a platform designed to supportthe fireplace weight (240lbs.) and venting. Hearth Raised Platform
Page 19 - RAISED FIREPLACE WITH RAISED HEARTH
Page 19 REMINGTON QFP40 Direct Vent FIREPLACE 250-4721 JUNE 2001 INST ALLA TION Raised Platform Raised Hearth RAISED FIREPLACE WITH RAISED HEARTH
Page 20 - HEARTH REQUIREMENTS
REMINGTON QFP40 Direct Vent FIREPLACE Page 20 250-4721 JUNE 2001 INST ALLA TION HEARTH REQUIREMENTS No clearances to combustible flooring are required for installation of the Remington QFP40,as referenced in the Clearances to Combustibles on page 7 of this manual. NOTE: Ensure the depth of your floo...
Page 21 - MANTEL REQUIREMENTS
Page 21 REMINGTON QFP40 Direct Vent FIREPLACE 250-4721 JUNE 2001 INST ALLA TION MANTEL REQUIREMENTS COMBUSTIBLE MANTELS As referenced on page 7, Clearance to Combustible Materials: The allowable height from the top of the glass to the lower edge of amaximum mantel depth of 12", is 30 1/2". T...
Page 22 - FASCIA DIMENSIONS
REMINGTON QFP40 Direct Vent FIREPLACE Page 22 250-4721 JUNE 2001 FASCIA DIMENSIONS ARCHED Part #841-0710 Gold Part #841-0750 Brushed Nickel Part #841-0720 Black 40 1/2" R53 7/16" 31" 17 1/2" 28 7/8" 32 13/16" 7 3/16" INST ALLA TION ACID WASH ALERT! An acid wash (muriatic ...
Page 24 - FACING REQUIREMENTS
REMINGTON QFP40 Direct Vent FIREPLACE Page 24 250-4721 JUNE 2001 INST ALLA TION FACING REQUIREMENTS HEADER NON-COMBUSTIBLEFACING 3" MIN. FORARCHED orRECTANGULARFASCIA Durarock or other non-combustible material must extendfrom header to floor and to framing on either side. NOTE: Tile may be tucke...
Page 26 - VENTING; GENERAL VENTING INSTRUCTIONS
REMINGTON QFP40 Direct Vent FIREPLACE Page 26 250-4721 JUNE 2001 VENTING GENERAL VENTING INSTRUCTIONS PLEASE NOTE: In order to comply with applicable codes and product warranties, only Simpson Dura-Vent venting components may be used. DO NOT USE FIELD-FABRICATED VENTING COMPONENTS. The Quadra-Fire R...
Page 27 - SIMPSON DURA-VENT PARTS LIST
Page 27 REMINGTON QFP40 Direct Vent FIREPLACE 250-4721 JUNE 2001 VENTING SIMPSON DURA-VENT PARTS LIST Simpson Dura-Vent offers a complete line of component parts for installation in both horizontaland vertical applications. Many items are offered in decorative black, as well as a galvanizedfinish. T...
Page 28 - VENTING INSTALLATION OPTIONS & GUIDELINES
REMINGTON QFP40 Direct Vent FIREPLACE Page 28 250-4721 JUNE 2001 VENTING VENTING INSTALLATION OPTIONS & GUIDELINES There are four types of direct vent system installations approved for use with the REMINGTONQFP40. It is very important to maintain a balance between the combustion air intake and t...
Page 29 - FIG. 1 HORIZONTAL TERMINATION; TERMINATION
Page 29 REMINGTON QFP40 Direct Vent FIREPLACE 250-4721 JUNE 2001 VENTING FIG. 1 HORIZONTAL TERMINATION TERMINATION CAP REQUIREMENTS: ON HORIZONTAL TERMINATIONS USE ONLY DURAVENT PART # 985, OR ALADDIN HEARTH PRODUCTS PART #HHW2 VERTICAL TERMINATIONS USE ONLY DURAVENT PART #991. FIG. 2 VERTICAL TERMI...
Page 30 - FIG. 3 INSTALLATION INTO A CLASS A METAL CHIMNEY
REMINGTON QFP40 Direct Vent FIREPLACE Page 30 250-4721 JUNE 2001 FIG. 3 INSTALLATION INTO A CLASS A METAL CHIMNEY (USA ONLY) VENTING INSTALLATION, CONT. VENTING Dura Vent #991ONLY High WindTermination Cap Top Adapter 4" Flex Pipe Retro Connector Direct Vent Pipe Existing MetalChimney System
Page 31 - FIG. 4 INSTALLATION INTO A MASONRY CHIMNEY
Page 31 REMINGTON QFP40 Direct Vent FIREPLACE 250-4721 JUNE 2001 FIG. 4 INSTALLATION INTO A MASONRY CHIMNEY (USA ONLY) DuraVent #991 HighWind Termination CapONLY Top Adapter Flashing Direct VentPipe RetroConnector 4" Flex Liner VENTING INSTALLATION, CONT. VENTING
Page 32 - HOW TO USE VENT GRAPH
REMINGTON QFP40 Direct Vent FIREPLACE Page 32 250-4721 JUNE 2001 VENTING HOW TO USE VENT GRAPH TOTAL HORIZONTAL RUN TO OUTSIDE OF EXTERIOR WALL (EXCLUDING ELBOWS) 2' 4' 6' 8' 10' 12' 14' 16' 18' 20' 22' 24' 26' 28' 30' 11" 2' 4' 6' 8' 10' 12' 14' 15' (MIN) (MAX) VERTICAL DISTANCE FROM APPLIANCE ...
Page 33 - HORIZONTAL TERMINATION REQUIREMENTS
Page 33 REMINGTON QFP40 Direct Vent FIREPLACE 250-4721 JUNE 2001 A Openable FixedClosed B C F G H I A V V V V K A J M N V = vent terminal A = air supply inlet HORIZONTAL TERMINATION REQUIREMENTS VENTING A. *12” (30cm) minimum: Clearance above grade, veranda, porch, deck, or balcony. B. *12” (30cm) m...
Page 34 - HORIZONTAL INSTALLATION
REMINGTON QFP40 Direct Vent FIREPLACE Page 34 250-4721 JUNE 2001 Step 1. Determine the desired location of the fireplace. Check to ensure that wall studs or roof rafters are not in the way when the venting system is attached. If this isthe case, you may want to adjust the location of the stove. Step...
Page 38 - VERTICAL INSTALLATION INSTRUCTIONS
REMINGTON QFP40 Direct Vent FIREPLACE Page 38 250-4721 JUNE 2001 VERTICAL INSTALLATION INSTRUCTIONS USING GS SERIES PIPE Step 1. Check the installation instructions for required 1" clearances (air space) to com-bustibles when passing through ceilings, walls, roofs, enclosures, attic rafters, oro...
Page 46 - GAS
REMINGTON QFP40 Direct Vent FIREPLACE Page 46 250-4721 JUNE 2001 GAS LINE REQUIREMENTS ✔ The gas line must be installed in accordance with all local codes, if any; if not, follow ANSI 223.1 and the requirements listed below. Ensure that a 1 1/4" allowance frombase of unit is made for hard pipe i...
Page 47 - ELECTRICAL CONNECTION; ELECTRICAL
Page 47 REMINGTON QFP40 Direct Vent FIREPLACE 250-4721 JUNE 2001 ELECTRICAL CONNECTION Make sure the household breaker is shut off prior to working on any electricallines.This appliance, when installed, must be electrically grounded in acordancewith local codes or, in the absence of local codes, wit...
Page 48 - BRICK; BRICK INSTALLATION
REMINGTON QFP40 Direct Vent FIREPLACE Page 48 250-4721 JUNE 2001 . 1. Place rear brick behind log rack against rear wall of firebox as shown in Fig. 1. NOTE: BRICK IS FRAGILE. HANDLE WITH CARE. Installation of the brick set should be made prior to the logset, nugget and lavarock installation. Option...
Page 50 - LOGSET AND NUGGET INSTALLATION; LOGSET
REMINGTON QFP40 Direct Vent FIREPLACE Page 50 250-4721 JUNE 2001 1. Install complete bag of lavarock in indicated gray area ONLY shown in Figs. 1 & 2. LOGSET AND NUGGET INSTALLATION NOTE: If you plan to install the optional brick set, do so prior to installing the logset,nuggets and lava rock. C...
Page 53 - INSTALLING GLASS; GLASS; INSTALLING FASCIA
Page 53 REMINGTON QFP40 Direct Vent FIREPLACE 250-4721 JUNE 2001 All arched and rectangular fascia attach to four flanges located two to each side of the glass frame. Insert and finger start bolts tightening with the 5/32" Allen wrench supplied withunit. INSTALLING GLASS The glass assembly has a...
Page 54 - LEAK TEST; LEAK
REMINGTON QFP40 Direct Vent FIREPLACE Page 54 250-4721 JUNE 2001 LEAK TEST 1. Turn on gas to the fireplace. 2. Turn on gas at the manual shutoff valve. 3. Leak test all gas joints prior to starting the appliance. 4. Familiarize yourself with the control panel components, see page 58. 5. Follow Light...
Page 55 - LIGHTING
Page 55 REMINGTON QFP40 Direct Vent FIREPLACE 250-4721 JUNE 2001 LIGHTING INSTRUCTIONS LIGHTING FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion mayresult causing property damage, personal injury or loss of life. A. This appliance has...
Page 56 - ADJUSTMENTS
REMINGTON QFP40 Direct Vent FIREPLACE Page 56 250-4721 JUNE 2001 ADJUSTMENTS ADJUSTING THE BLOWER SPEED The blower will turn on automatically within approximately 10 minutes after start-up and thefireplace is up to temperature. This aids in transferring the heat into the living area. The blowerspeed...
Page 58 - OPERA
REMINGTON QFP40 Direct Vent FIREPLACE Page 58 250-4721 JUNE 2001 OPERATION Read this entire manual prior to using the fireplace. Pay particular attention to the “SafetyPrecautions” section on pages 6-9. Failure to follow the instructions may result in prop-erty damage, bodily injury, or even death. ...
Page 59 - MAINTENANCE
Page 59 REMINGTON QFP40 Direct Vent FIREPLACE 250-4721 JUNE 2001 MAINTENANCE GENERAL Installation and repair should be done by a qualified service person. The applianceshould be inspected before use and at least annually by a professional service person.More frequent cleaning may be required due to ...
Page 60 - YEARLY SERVICING PROCEDURES
REMINGTON QFP40 Direct Vent FIREPLACE Page 60 250-4721 JUNE 2001 YEARLY SERVICING PROCEDURES WARNING! Failure to inspect and maintain the fireplace may lead to improper com- bustion and apotentially dangerous situation. The following procedures are rec-ommended to be completed by a qualified technic...
Page 61 - GLASS REPLACEMENT
Page 61 REMINGTON QFP40 Direct Vent FIREPLACE 250-4721 JUNE 2001 Replace glass with part #842-3820 ONLY, available from your dealer. 1. Turn valve to “OFF” position to prevent start-up of unit while door is removed. 2. Prepare a flat area to lay the door on by covering the surface with cardboard,dis...
Page 62 - BLOWER REPLACEMENT
REMINGTON QFP40 Direct Vent FIREPLACE Page 62 250-4721 JUNE 2001 MAINTENANCE BLOWER REPLACEMENT Part #842-3790 1. Disconnect power to unit at power supply (this may require shutting off power at the circuit breaker box). 2. Remove fascia and door. 3. Remove control panel cover. 4. Disconnect white w...
Page 63 - ELECTRICAL SCHEMATIC
Page 63 REMINGTON QFP40 Direct Vent FIREPLACE 250-4721 JUNE 2001 MAINTENANCE ELECTRICAL SCHEMATIC
Page 64 - TROUBLESHOOTING; TROUBLSHOOTING
REMINGTON QFP40 Direct Vent FIREPLACE Page 64 250-4721 JUNE 2001 TROUBLESHOOTING Pilot won’t light ✔ Is a gas shut-off valve turned on? ✔ Is the valve control knob turned to “PILOT”(See Lighting Instructions, #7, Pg. 55). ✔ Is the valve control knob pushed in? (See Lighting Instructions, #8) ✔ Was t...
Page 66 - ARTS
REMINGTON QFP40 Direct Vent FIREPLACE Page 66 250-4721 JUNE 2001 PARTS & ACCESSORIES PARTS 842-0240 Valve (NG) 842-3501 Pilot 842-3910 Pilot Orifice NG (.025) 842-3900 Pilot Orifice LP (.016) 842-4480 Logset (7 pieces) 842-4490 Rear Log 842-4520 Front Log 842-4500 Left Twig 842-4510 Right Twig 8...
Page 67 - WARRANTY; North America’s Best; ARRANTY
Page 67 REMINGTON QFP40 Direct Vent FIREPLACE 250-4721 JUNE 2001 WARRANTY GAS APPLIANCE LIMITED LIFETIME WARRANTY Aladdin Hearth Products, warrants this gas heating appliance to the original purchaser for the lifetime of theappliance, to be free from defects in material and workmanship. This warrant...