Page 2 - REGENCY; Products International Ltd. The Regency
2 Regency ® U39 ULTIMATE Direct Vent Freestanding Gas Stove REGENCY ® ULTIMATE Direct Vent Freestanding Gas Stove To the New Owner: Congratulations! You are the owner of a state-of-the-art ULTIMATE Direct Vent Gas Stove by FPI Fireplace Products International Ltd. The Regency ® Gas Series of hand cr...
Page 3 - TABLE OF CONTENTS
Regency ® U39 ULTIMATE Direct Vent Freestanding Gas Stove 3 TABLE OF CONTENTS SAFETY LABEL Copy of Safety Label ..................................................... 4 REQUIREMENTS MA Code - CO Detector ................................................ 5 INSTALLATION Important Message ..................
Page 4 - SAFETY LABEL; Copy of Safety Label for U39 Gas Stove; Regency
4 Regency ® U39 ULTIMATE Direct Vent Freestanding Gas Stove This is a copy of the label that accompanies each ULTIMATE Direct Vent Freestanding Gas Stove. We have printed a copy of the contents here for your review. The safety SAFETY LABEL label is located on the inside of the drop down pedestal doo...
Page 5 - REQUIREMENTS; MA Code - CO Detector
Regency ® U39 ULTIMATE Direct Vent Freestanding Gas Stove 5 REQUIREMENTS 5.08: Modifications to NFPA-54, Chapter 10 (2) Revise 10.8.3 by adding the following additional requirements: (a) For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure use...
Page 6 - INSTALLATION
6 Regency ® U39 ULTIMATE Direct Vent Freestanding Gas Stove IMPORTANT MESSAGE SAVE THESE INSTRUCTIONS The ULTIMATE Direct Vent Freestanding Gas Stove must be installed in accordance with these instructions. Carefully read all the instructions in this manual fi rst. Consult the building authority havi...
Page 8 - Minimum ceiling
8 Regency ® U39 ULTIMATE Direct Vent Freestanding Gas Stove For Vent Termination requirements, see "Exterior Vent termination Locations" section. LOUVER INSTALLATION 1) Attach the top & bottom louvers to the side stove panel using 2 screws per side. INSTALLATION MANUFACTURED MOBILE HOME ...
Page 9 - EXTERIOR VENT TERMINAL LOCATIONS; AstroCap
Regency ® U39 ULTIMATE Direct Vent Freestanding Gas Stove 9 EXTERIOR VENT TERMINAL LOCATIONS A = Clearance above grade, veranda, porch, deck, or balcony *(min. 12"/30cm) B= Clearance to window or door that may be opened *(12"/30cm) C= Clearance to permanently closed window *(min. 12"/30c...
Page 10 - ” X 6-5/8” RIGID PIPE CROSS REFERENCE CHART
10 Regency ® U39 ULTIMATE Direct Vent Freestanding Gas Stove 4” X 6-5/8” RIGID PIPE CROSS REFERENCE CHART Components from different Manufacturers may not be mixed. Not All Rigid Pipe components are available directly from FPI. Description Simpson Direct Vent Pro ® Simpson Direct Vent GS ® Discontinu...
Page 11 - Offset Pipe Selection:; Use this table to determine offset pipe lengths.
Regency ® U39 ULTIMATE Direct Vent Freestanding Gas Stove 11 Description Simpson Direct Vent Pro ® Simpson Direct Vent GS ® Discontinued Selkirk Direct-Temp™ American Metal Products ® Amerivent Direct Metal-Fab ® Sure Seal Security Secure Vent ® Attic Insulation Shield 12” 46DVA-IS - N/A from FPI N/...
Page 12 - RIGID PIPE VENTING SYSTEMS; Horizontal or Vertical Terminations; Alternate
12 Regency ® U39 ULTIMATE Direct Vent Freestanding Gas Stove RIGID PIPE VENTING SYSTEMS Horizontal or Vertical Terminations Alternate Horizontal Ter- mination Caps INSTALLATION This product has been evaluated by Intertek for using a Rigid Pipe Adaptor in conjunction with Duravent Direct-Vent GS, Sel...
Page 14 - Option V; Option V
14 Regency ® U39 ULTIMATE Direct Vent Freestanding Gas Stove Horizontal Venting with Two (2) 90 o Elbows Option V H + H1 A) 3' Min. 2' Max. B) 5' Min. 3' Max. C) 8' Min. 4' Max. With these options, maximum total pipe length is 30 feet with minimum of 8 feet total vertical and maximum 4 feet total ho...
Page 15 - DV STOVE HORIZONTAL VENT KIT INSTALLATION
Regency ® U39 ULTIMATE Direct Vent Freestanding Gas Stove 15 INSTALLATION DV STOVE HORIZONTAL VENT KIT INSTALLATION Minimum Installation Height: U39: 59-3/4" ( 1518mm) DV STOVE HORIZONTAL VENT KIT (# 946-116 & #946-216) DV Stove Horizontal Vent Kit (2 ft. Part # 946-116 or 4 ft. Part # 946-2...
Page 17 - Alternate Horizontal; Elbow; TERMINATION KIT; Planning Your Dura-Vent; COMPONENTS
Regency ® U39 ULTIMATE Direct Vent Freestanding Gas Stove 17 Alternate Horizontal Termination Caps Dura-Vent Basic Horizontal Kit # 970 1 90 o Elbow 1 Wall Thimble Cover1 Horiz. Sq. Term. Cap DURA-VENT TERMINATION KIT Planning Your Dura-Vent Installation There are two basic types of Dura-Vent Direct...
Page 18 - HORIZONTAL; Diagram 1
18 Regency ® U39 ULTIMATE Direct Vent Freestanding Gas Stove NOTE: For Snorkel terminations in ABOVE grade installations, follow national or local code requirements. Diagram 3a Note: Riser Vent is only for use in above grade terminations. U39: 59-3/4" (1518mm) Diagram 2 Note: a) The horizontal r...
Page 19 - TERMINATIONS
Regency ® U39 ULTIMATE Direct Vent Freestanding Gas Stove 19 Diagram 10 Diagram 9 Diagram 8 Diagram 7 Diagram 6 7) Install the Wall Thimble in the center of the 10" square and attach with wood screws. 8) Slide the decorative wall thimble up to the wall surface being careful not to scratch the pa...
Page 20 - Offset Chart; CATHEDRAL CEILINGS; Slope
20 Regency ® U39 ULTIMATE Direct Vent Freestanding Gas Stove INSTALLATION Diagram 11: The upper half of the fl ashing is installed under the roofi ng material and not nailed down until the chimney is installed. This allows for small adjustments. 4) Assemble the desired lengths of black pipe and elbows...
Page 21 - Support Extensions - Round; CONVERTING A; General; Converting a Factory Built Metal
Regency ® U39 ULTIMATE Direct Vent Freestanding Gas Stove 21 INSTALLATION Using a level, make sure the support is vertical. If the support extends above the roof, cut it fl ush with the top of the roof. Nail the support to the frame opening using (8) 3" spiral nails or #8 x 1-1/2" screws. Not...
Page 22 - Converting a Masonry Chimney
22 Regency ® U39 ULTIMATE Direct Vent Freestanding Gas Stove Converting a Masonry Chimney Important: The existing masonry flue opening needs to have an area of at least a 36 sq. in. to insure proper intake/exhaust fl ow. 1) Before cutting any holes, assemble the desired sections of black direct vent ...
Page 23 - System Data; GAS CONNECTION
Regency ® U39 ULTIMATE Direct Vent Freestanding Gas Stove 23 U39-NG1: For 0 to 2000 feet altitude U39-LP1: For 0 to 4500 feet altitude Burner Inlet Orifi ce Sizes: Natural Gas Propane Burner #32 #50 Max. Input - Natural Gas/Propane 38,000 Btu/h Min. Input - Natural Gas/Propane 20,000 Btu/h Supply Pre...
Page 24 - THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER
24 Regency ® U39 ULTIMATE Direct Vent Freestanding Gas Stove CONVERSION KIT# 731-969 FROM NG TO LP THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !! 1) Shut off the gas supply. 2) Open the front door and carefully remove the logs and lava rock. Pilot ass...
Page 25 - ONLY REQUIRED FOR THE U38
Regency ® U39 ULTIMATE Direct Vent Freestanding Gas Stove 25 16) Pull off the pilot cap to expose the pilot orifi ce. 17) Unscrew the pilot orifi ce with the allen key and replace with the LPG pilot orifi ce in the kit. 19) Reinstall new burner orifi ce LPG stamped #50 and tighten. 20) Reverse steps...
Page 27 - GAS PIPE PRESSURE; THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS
Regency ® U39 ULTIMATE Direct Vent Freestanding Gas Stove 27 GAS PIPE PRESSURE TESTING The appliance must be isolated from the gas supply piping system by closing its individual manual shut-off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than ...
Page 28 - AERATION; Valve Description
28 Regency ® U39 ULTIMATE Direct Vent Freestanding Gas Stove AERATION ADJUSTMENT The burner aeration is factory set but may need adjusting due to either the local gas supply or altitude. U39 with 38,000 Btu/h U39-NG1 Natural Gas: 1/4" open U39-LP1 Propane: 1/2" open U39 with 30,000 Btu/h U39...
Page 29 - LOG SET INSTALLATION; Embers; do; Pins on Rear Log Support; The gas log kit contains the following:
Regency ® U39 ULTIMATE Direct Vent Freestanding Gas Stove 29 LOG SET INSTALLATION INSTALLATION Embers Embers The "02" refer numbers (i.e. 02-65) are molded into the rear of each log. Note: Install Optional Brick Panels prior to installing logs. 1) Carefully remove the logs from the box and u...
Page 30 - Cutout
30 Regency ® U39 ULTIMATE Direct Vent Freestanding Gas Stove Cutout Pin D)02-46 B)02-56 A)02-65 7) Place the Left Top Log D)02-46 on the pin on Log B)02-56 and on top of the cutout on Log A)02-65. E)02-45 C)02-44 8) Place Front Right Log E)02-45 on the two pins as shown. 9) Place the lava rock in th...
Page 32 - WIRING DIAGRAM; WARNING: Electrical Grounding Instructions
32 Regency ® U39 ULTIMATE Direct Vent Freestanding Gas Stove WIRING DIAGRAM CAUTION: Label all wires prior to disconnection when servicing c o n t r o l s . W i r i n g e r r o r s c a n cause improper and dangerous WARNING: Electrical Grounding Instructions This appliance is equipped with a three p...
Page 33 - OPTIONAL WALL; FINAL CHECK
Regency ® U39 ULTIMATE Direct Vent Freestanding Gas Stove 33 14 GA.16 GA.18 GA.20 GA.22 GA. 50 Ft.32 Ft.20 Ft.12 Ft. 9 Ft. Recommended Maximum Lead Length (Two-Wire) When Using Wall Thermostat (CP-2 System) Wire Size Max. Length Thermostat Wire Table OPTIONAL WALL THERMOSTAT A wall thermostat may be...
Page 34 - OPERATING INSTRUCTIONS; HOT; IMPORTANT
34 Regency ® U39 ULTIMATE Direct Vent Freestanding Gas Stove OPERATING INSTRUCTIONS SHUTDOWN INSTRUCTIONS 1) Use the Burner ON/OFF switch, thermostat or remote control to turn off the burner. 2) Push in the PILOT knob slightly and turn clockwise to off. Do not force. 3) Turn off all electric power t...
Page 35 - DO NOT REMOVE THIS INSTRUCTION PLATE; Copy Of Lighting Plate Instructions
Regency ® U39 ULTIMATE Direct Vent Freestanding Gas Stove 35 1) Push in gas control knob slightly and turn to “PILOT” position. 2) Push in control knob all the way and hold in until the pilot lights up. Continue to hold the control knob in for about 20 seconds after the pilot is lit. Release knob. 3...
Page 36 - MAINTENANCE; WA R N I N G : C H I L D R E N A N D; GENERAL VENT
36 Regency ® U39 ULTIMATE Direct Vent Freestanding Gas Stove MAINTENANCE MAINTENANCE INSTRUCTIONS 1) Always turn off the valve before cleaning. For relighting, refer to lighting instructions. Keep the burner and control compartment clean by brushing and vacuuming at least once a year. When cleaning ...
Page 37 - Mitred Glass Replacement; Panel Glass Replacement; LOG REPLACEMENT; DOOR GASKET
Regency ® U39 ULTIMATE Direct Vent Freestanding Gas Stove 37 Mitred Glass Replacement Removing Glass 1) Remove the door from the unit and place on a soft surface to prevent scratching. 2) Pull out the door gasket. 3) Remove the 24 nuts holding the glass retainers in place. Do not remove the nuts und...
Page 38 - FAN MAINTENANCE; Electrical Grounding; DC SPARKER BATTERY
38 Regency ® U39 ULTIMATE Direct Vent Freestanding Gas Stove MAINTENANCE FAN MAINTENANCE If your fan requires maintenance or replacement, access to the fan is through the plate on the rear wall of the fi rebox. NOTE: the unit MUST NOT be operated without the fan access panel securely in place and cor...
Page 39 - REMOVING VALVE
Regency ® U39 ULTIMATE Direct Vent Freestanding Gas Stove 39 REMOVING VALVE 2) Undo the six screws holding the control panel in place. 3) Disconnect all wires from the back of the panel and then remove panel. You should lay the panel on a soft cloth so it doesn't get marked up. See diagram below. 6)...
Page 40 - PARTS LIST; MAIN ASSEMBLY
40 Regency ® U39 ULTIMATE Direct Vent Freestanding Gas Stove PARTS LIST 30) 630-021 Fan Access Panel 31) 730-019 Rear Panel 32) 730-565 Firebox Baffl e/Restrictor Assy 33) 630-520 False Top Assembly 36) 936-194 Gasket-Starter Collar/Air Passage 37) * Gasket-Flue Collar/Starter Collar 38) 820-058 Pede...
Page 41 - BURNER & LOG ASSEMBLY
Regency ® U39 ULTIMATE Direct Vent Freestanding Gas Stove 41 BURNER & LOG ASSEMBLY 51) 910-241 Burner ON/OFF Switch (3-way) 52) 910-190 Piezo Ignitor & Nut 53) 904-586 Knob for Fan Speed Control 54) 910-373 Knob - Pilot Valve Extension 55) 910-372 Flame Adjusting Knob 56) 908-646 Control Pan...
Page 42 - DOOR ASSEMBLIES
42 Regency ® U39 ULTIMATE Direct Vent Freestanding Gas Stove PARTS LIST DOOR ASSEMBLIES Part # Description 730-923 Brush Nickel Mitred Door - Complete 730-924 Gold Mitred Door - Complete 730-926 Black Mitred Door - Complete 730-932 Gold Wrap Door - Complete 730-928 Gold Panel Door - Complete 101) 65...
Page 43 - WARRANTY
Regency ® U39 ULTIMATE Direct Vent Freestanding Gas Stove 43 WARRANTY Regency Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each unit thoroughly before it leaves our facility. FPI Fireplace Products Intern...
Page 44 - Installer: Please complete the following information; Printed in Canada; Register your Regency
Installer: Please complete the following information Dealer Name & Address: ______________________________________________ ___________________________________________________________________ Installer: ___________________________________________________________ Phone #: _________________________...