1 Page 1
2 Page 2
Page: / 2
Loading the manual

U38 Top Vent Freestanding B-Vent Gas Stove

Model

U38-NG1

U38-LP1

Fuel Type

Natural Gas

Propane

Minimum Supply Pressure

5” W.C. (1.25 kPa)

12” W.C. (3.00 kPa)

Manifold Pressure - High

3.8” W.C. (0.94 kPa)

11” W.C. (2.74 kPa)

Manifold Pressure - Low

1.1” W.C. (0.27 kPa)

2.9” W.C. (0.72 kPa)

Orifi ce Size

Altitude 0-2000ft (0-610m)

#31

#50

Orifi ce Size

Altitude 2000-4500ft (610-1370m)

#33

Orifi ce Size

30,000 Max BTU

#37

#52

Minimum Input

Altitude 0-2000ft (0-610m)

21,000 BTU/h

20,000 BTU/h

Minimum Input

Altitude 2000-4500ft (610-1370m)

19,000 BTU/h

Minimum Input

Converted to 30,000 Max BTU

15,000 BTU/h

15,000 BTU/h

Maximum Input

Altitude 0-2000ft (0-610m)

40,000 BTU/h

38,000 BTU/h

Maximum Input

Altitude 2000-4500ft (610-1370m)

36,000 BTU/h

Maximum Input

Converted to 30,000 Max BTU

30,000 BTU/h

30,000 BTU/h

Vent Sizing

4” B-Vent

4” B-Vent

Dimension

Description

U38

A

Top Width

26” (660mm)

B

Unit Height

30” (762mm)

C

Top Depth (back to front face)

17-5/8” (448mm)

D

Top Depth

17” (432mm)

E

Height; Base to Gas Line

3-1/2” (89mm)

F

Top; Front to Back

17” (432mm)

G

Depth; Flue-Centerline to Back

3-1/2” (89mm)

H

Width; Side of unit to Gas Line

10-3/4” (273mm)

F

G

H

A

C

D

B

E

U38 Gas Stove

I

J

K

L

I

M

N

N

M

Alcove clearances

Dimension

Description

U38

I

Side Wall to Unit

7-1/2” (190mm)

J

Back Wall to Unit

6” (155mm)

K

Back Wall to Vent Centerline

10-3/4” (273mm)

L

Side Wall to Vent Centerline

20-1/2” (521mm)

Corner Clearances

Dimension

Description

U38

M

Wall to Unit Corner

2” (50mm)

N

Wall to Vent Centerline

11” (280mm)

Minimum ceiling height is 36" (914mm) from top of unit.

Minimum clearance to vent : According to B-Vent Manufacturer

The above listed clearances are minimum distances to combustible

materials. When installing on carpet or vinyl fl ooring the bottom pedestal

cover plate must be installed.

Approved Venting Systems

Vent Systems:

Listed B-Vent, Class-A or Masonry
Chimney with approved liner (FPI
AstroCap™ Flex Vent)

155