Regency P48-NG2 - Manual
Regency P48-NG2 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – Framing and Finishing; Frame in the enclosure for the unit with framing material.; Mantel Leg Clearances; P48 Gas Fireplace; WARNING; Combustible Mantels; Combustible mantel clearances from top of; Clearance Requirements; Gas Fireplaces
- Page 3 – Snorkel Ter minations; Snorkel Terminations:; Snorkel; Horizontal Terminations Only; AstroCap; June 2007 Regency Product Specifi cations Book
- Page 4 – Rigid Pipe Venting; Rigid Pipe System; Alternate Horizontal
- Page 5 – Two 45° elbows = One 90° elbow; Two 45° elbows = One 90° elbow
- Page 6 – Venting Arrangements - Horizontal; using one 45° and one 90° elbow; Maintain clearances to combustibles.; Note: FPI Direct Vent System (Flex) is only approved for horizontal; Please refer to Page 11 (Exterior Vent Terminations)
P48 Zero Clearance Direct Vent Gas Fireplace
Model
P48-NG2
P48-LP2
Fuel Type
Natural Gas
Propane
Minimum Supply Pressure
5” W.C. (1.25 kPa)
12” W.C. (3.00 kPa)
Manifold Pressure - High
3.8” W.C. (0.95 kPa)
11” W.C. (2.74 kPa)
Manifold Pressure - Low
1.1” W.C. (0.27 kPa)
3.3” W.C. (0.82 kPa)
Orifi ce Size
#27 DMS - 0-4500ft
#47 DMS
Minimum Input
29,000 BTU/h (8.49 kW)
26,000 BTU/h (3.07 kW)
Maximum Input
51,000 BTU/h (14.94 kW)
48,000 BTU/h (6.30 kW)
Vent Sizing
5” Inner / 8” Outer
5” Inner / 8” Outer
A
B
A
D
C
F
E
G
H
I
K
J
L
O P
N
M
11" (279mm)
dia. Hole through
wall Vent.
Opening for gas
connection
Top Header
Drywall
(or other
facing)
P48 Gas Fireplace
Unit Dimensions
Description
P33
A
Front Face Width
48” (1219mm)
B
Rear Firebox Width
34-1/2” (876mm)
C
Front Face Height
41” (1041mm)
D
Height w/ Standoff
47” (1193mm)
E
Unit Depth
23-1/4” (324mm)
F
Firebox Height
40” (1016mm)
Framing Dimensions
Description
P33
G
Framing Width
48-1/2” (1232mm)
H
***
Framing Height
***
47-1/2” (1207mm)
***
I
Framing Depth
29-3/4” (756mm)
Vertical Rise
26-1/4” (667mm)
No Vertical Rise
J
Corner Wall Length
57-5/8
” (1464mm)
K
Corner Facing Wall Width
81-1/2” (2070mm)
L
Framed Chase Ceiling
N/A -
Vertical Rise
50” (1270mm)
No Vertical Rise
M
Vent Centerline Height
43” (1092mm)
N
Gas Connection Height
2” (51mm)
O
Gas Connection Inset
3-3/4” (95mm)
P
Gas Connection Width
5” (127mm)
Approved Venting Systems
Flex Vent Systems:
FPI AstroCap™ Flex Vent
Rigid Pipe Vent Systems:
Simpson Dura-Vent® Direct Vent GS
***
Important: Framing height requires consideration of the hearth
depth. Dimension H = H + the thickness of installed hearth.
Please refer to Page 11 (Exterior Vent Terminations)
for additional guidelines on vent locations.
61
June 2007 Regency Product Specifi cations Book
Gas Fireplaces
Gas Fir
eplaces
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
Framing and Finishing 1) Determine the total thickness of facing material (e.g. drywall plus ceramic tiles) to allow the fi nished surface to be fl ush with the front of the unit. Total facing thickness can vary from 1/2” (13mm) to 1-¼” (32mm) thick. 2) Frame in the enclosure for the unit with framing...
8" dia. Flue pipe 5” dia. Flue pipe Spring Spacer AstroCap XL (Part# 946-623/P) Wall Thimble Vinyl Siding Standoff Alternate Horizontal Termination Caps Snorkel Ter minations Snorkel Terminations: For installations requiring a vertical rise on the exterior of the building, 14-inch and 36-inch ta...
Pipe Length Vertical Terminal Storm Collar Flashing Ceiling Firestop 24" Length Adj.Pipe Length 11" - 14-5/8” 90 Elbow o Horizontal Termination Cap # 946-623/P Wall Thimble Vinyl Siding Standoff Rigid Pipe Adapter # 770-994 45 Elbow o Adj.Pipe Length 11" - 14-5/8” Horizontal Termination ...