Page 2 - MANUFACTURED MOBILE HOME REQUIREMENTS; INFORMATION FOR MOBILE/MANUFACTURED HOMES AFTER FIRST SALE
Regency ® P48-2 Zero Clearance Direct Vent Gas Fireplace 2 To the New Owner: Congratulations! You are the owner of a state-of-the-art Gas Fireplace by REGENCY ® . The P48-2 has been designed to provide you with all the warmth and charm of a wood fi replace at the fl ick of a switch. The model P48-2 ha...
Page 3 - TABLE OF CONTENTS
Regency ® P48-2 Zero Clearance Direct Vent Gas Fireplace 3 TABLE OF CONTENTS Optional Bay Door ....................................................... 35Optional Bay Trim ........................................................ 35Bay Louvers .............................................................
Page 4 - SAFETY LABEL; COPY
Regency ® P48-2 Zero Clearance Direct Vent Gas Fireplace 4 This is a copy of the label that accompanies each P48-NG2 and P48-LP2 Zero Clearance Direct Vent Gas Fireplace. We have printed a copy of the contents here for your review. The safety label is located on the front inside base of the unit, vi...
Page 5 - REQUIREMENTS; MA Code - CO Detector
Regency ® P48-2 Zero Clearance Direct Vent Gas Fireplace 5 REQUIREMENTS 5.08: Modifications to NFPA-54, Chapter 10 (2) Revise 10.8.3 by adding the following additional requirements: (a) For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used...
Page 6 - INSTALLATION
Regency ® P48-2 Zero Clearance Direct Vent Gas Fireplace 6 12) Installation and any repairs to this appliance should be done by an authorized service person. A professional service person should be called to inspect this appliance annually. Make it a practice to have all of your gas appliances check...
Page 8 - CLEARANCES; Heat Release Kit
Regency ® P48-2 Zero Clearance Direct Vent Gas Fireplace 8 CLEARANCES The clearances listed below are Minimum distances unless otherwise stated: A major cause of chimney related fi res is failure to maintain required clearances (air space) to combustible materials. It is of the greatest importance th...
Page 9 - MANTELS; MANTEL LEG CLEARANCES
Regency ® P48-2 Zero Clearance Direct Vent Gas Fireplace 9 MANTELS Because of the extreme heat this fi replace emits, the mantel clearances are critical. Combustible mantel clearances from louver are shown in the diagram below. Note: A non-combustible mantel may be installed at a lower height if the ...
Page 10 - IMPORTANT
Regency ® P48-2 Zero Clearance Direct Vent Gas Fireplace 10 INSTALLATION Note: 43" (1092mm) is the minimum height for fl ex termination and Simpson Dura-Vent terminations. Diagram 1 1) Determine the total thickness of facing material (eg. drywall plus ceramic tiles) to allow the fi nished surface ...
Page 11 - UNIT ASSEMBLY; TOP STANDOFF ASSEMBLY
Regency ® P48-2 Zero Clearance Direct Vent Gas Fireplace 11 VENTING INTRODUCTION The P48-2 uses the "balanced fl ue" technology Co Axial system. The inner liner vents products of combustion to the outside while the outer liner draws outside combustion air into the combustion chamber thereby e...
Page 12 - EXTERIOR VENT TERMINATION REQUIREMENTS
Regency ® P48-2 Zero Clearance Direct Vent Gas Fireplace 12 INSTALLATION EXTERIOR VENT TERMINATION REQUIREMENTS A= Clearance above grade, veranda, porch, deck, or balcony *(min. 12"/30cm) B= Clearance to window or door that may be opened *(12"/30cm) C= Clearance to permanently closed window ...
Page 13 - VENTING ARRANGEMENTS; HORIZONTAL TERMINATION
Regency ® P48-2 Zero Clearance Direct Vent Gas Fireplace 13 VENTING ARRANGEMENTS HORIZONTAL TERMINATION Regency ® Direct Vent System (Flex) These venting systems, in combination with the P48-2 Direct Vent Gas Fireplace, have been tested and listed as a direct vent heater system by Warnock Hersey. Th...
Page 14 - Horizontal or Vertical Terminations; SIMPSON DURA-VENT VENTING; none
Regency ® P48-2 Zero Clearance Direct Vent Gas Fireplace 14 SIMPSON DURA-VENT VENTING Horizontal or Vertical Terminations The Simpson Dura-Vent Direct Vent System offers a complete line of component parts for installation of both horizontal and vertical installations. Many items are offered in decor...
Page 15 - ” X 8” RIGID PIPE CROSS REFERENCE CHART
Regency ® P48-2 Zero Clearance Direct Vent Gas Fireplace 15 Description Simpson Direct Vent Pro ® Simpson Direct Vent GS ® Discontinued Selkirk Direct-Temp™ Metal-Fab ® Sure Seal 6” Pipe Length, Galvanized 58DVA-06 1208 5DT-6 5D6 6” Pipe Length, Black 58DVA-06B 1208B 5DT-6B 5D6B 9” Pipe Length, Galv...
Page 16 - Offset Pipe Selection:
Regency ® P48-2 Zero Clearance Direct Vent Gas Fireplace 16 L676 & L900 Direct Vent Fireplace IMPORTANT NOTE • A Vent Guard is required when the AstroCap is installed above grade at 7 feet or lower.• The Simpson Dura-Vent and Selkirk Direct Temp horizontal termination caps cannot be used in any ...
Page 17 - SIMPSON DURA-VENT DIRECT VENT GS SYSTEM and
Regency ® P48-2 Zero Clearance Direct Vent Gas Fireplace 17 SIMPSON DURA-VENT DIRECT VENT GS SYSTEM and Regency ® DIRECT VENT SYSTEM (FLEX) (Propane & Natural Gas) The diagram shows all allowable combinations of vertical runs with horizontal terminations, using one 45 o and one 90 o elbow (two 4...
Page 18 - Elbows; Option
Regency ® P48-2 Zero Clearance Direct Vent Gas Fireplace 18 INSTALLATION Horizontal Venting with Two (2) 90 o Elbows Horizontal Venting with Two (2) 90 o Elbows Horizontal Venting with Three (3) 90 o Elbows One 90 o elbow = Two 45 o elbows. One 90 o elbow = Two 45 o elbows. One 90 o elbow = Two 45 o...
Page 21 - VERTICAL TERMINATIONS; SIMPSON DURA-VENT DIRECT VENT GS SYSTEM
Regency ® P48-2 Zero Clearance Direct Vent Gas Fireplace 21 INSTALLATION • Vent must be supported at offsets.• Firestops are required at each fl oor level and whenever passing through a wall.• Maintain clearances to combustibles. Note: Must use optional rigid pipe adapter when using Simpson Dura-Vent...
Page 23 - UNIT INSTALLATION
Regency ® P48-2 Zero Clearance Direct Vent Gas Fireplace 23 Diagram 7 Diagram 6 9) Install wall thimble in the center of the 11" (279mm) square and attach with wood screws (Diagram 7). Diagram 5 6) The arrow on the vent cap should be pointing up. Insure that the 1-1/4"(32mm) c l e a r a n c ...
Page 25 - UNIT; with Regency® Direct Vent; ASTROCAP XL
Regency ® P48-2 Zero Clearance Direct Vent Gas Fireplace 25 INSTALLATION 4) Separate the 2 halves of the wall thimble and securely fasten the one with the tabs to the outside wall making sure that the tabs are on top and bottom. Fasten the other thimble half to the inside wall. The thimble halves sl...
Page 27 - THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER; CONVERSION KIT FROM NG TO LPG PART #372-969
Regency ® P48-2 Zero Clearance Direct Vent Gas Fireplace 27 INSTALLATION 5) Pull off the pilot cap to expose the pilot orifi ce. 6) Unscrew the pilot orifi ce with the allen key and replace with the LP pilot orifi ce in the kit and replace pilot cap. 7) Remove burner orifi ce with a 1/2" wrench and ...
Page 28 - Installation of the DC Sparker:
Regency ® P48-2 Zero Clearance Direct Vent Gas Fireplace 28 INSTALLATION 17) Reverse steps 4) to 1). 18) Attach the label "This unit has been converted to LPG" near or on top of the serial # decal. 19) Replace yellow "Natural Gas" label with red "Propane" label 20) Check for ...
Page 30 - BRICK PANELS INSTALLATION
Regency ® P48-2 Zero Clearance Direct Vent Gas Fireplace 30 BRICK PANELS INSTALLATION 1) Unhook the 2 spring loaded hooks from the bottom of the fl ush door and lift the Flush Front off the unit. 2) Unwrap the brick pattern panels from the protective wrapping. Note: The logs must not be in the unit. ...
Page 31 - LOG SET INSTALLATION; Carefully remove the logs from the box and unwrap; do not; Line up the two holes on the underside of Log 02-88
Regency ® P48-2 Zero Clearance Direct Vent Gas Fireplace 31 INSTALLATION LOG SET INSTALLATION Read the instructions below carefully and refer to the dia-grams. If logs are broken do not use the unit until they are replaced. Broken logs can interfere with the pilot opera-tion. The gas log kit (Part #...
Page 32 - Place Log 02-83 onto the pin in Log 02-88 and position; CAUTION: DO NOT cover burner ports with embers.; the notch at the end of the log against the grate.
Regency ® P48-2 Zero Clearance Direct Vent Gas Fireplace 32 INSTALLATION 7) Place Log 02-83 onto the pin in Log 02-88 and position the notch on the bottom of the log into the 4th grate post. 6) Embers should be placed in front of Log 02-85 and Log 02-86. Separate platinum embers and place around the...
Page 33 - on the underside
Regency ® P48-2 Zero Clearance Direct Vent Gas Fireplace 33 INSTALLATION 10) Place Log 02-90 onto the right side of the grate. Posi- tion the cut-out on the underside of the log onto the grate bar. Cut-out on the underside of the log. Position the cut-out onto the grate bar. 11) Place Log 02-87 on t...
Page 34 - FLUSH LOUVERS
Regency ® P48-2 Zero Clearance Direct Vent Gas Fireplace 34 Diagram 1 Diagram 3 STANDARD FLUSH DOOR The standard fl ush door comes with a black frame. To install the frame, simply hook the top door fl ange onto the top of the unit and swing the door towards the unit, diagram 1. Diagram 2 NOTE: Springs...
Page 35 - BAY LOUVERS; OPTIONAL BAY DOOR
Regency ® P48-2 Zero Clearance Direct Vent Gas Fireplace 35 INSTALLATION BAY LOUVERS 1) Install top louver by sliding the two bracket clips into the brackets located on top of the bay door. See below. The fi tted louver leaves a small gap between faceplate bottom and louver top. Diagram 4 Diagram 3 O...
Page 37 - Thermostat Wire Table
Regency ® P48-2 Zero Clearance Direct Vent Gas Fireplace 37 INSTALLATION Can be used with Option 1 or 3 but not both. 1) Run the supplied 15' of wire through the back gas inlet opening. Be careful not to damage wire. Note: We recommend a maximum of 15' of wire but if you wish to go with a longer run...
Page 38 - WIRING DIAGRAMS; For; NATURAL GAS; Units and Units; NOT; Equipped with DC Spark Boxes
Regency ® P48-2 Zero Clearance Direct Vent Gas Fireplace 38 WIRING DIAGRAMS CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. No electrical power supply is required for the gas control to operate. 120 Volt AC power is n...
Page 39 - PROPANE; Units and Units Equipped with DC Spark Boxes*
Regency ® P48-2 Zero Clearance Direct Vent Gas Fireplace 39 INSTALLATION For PROPANE Units and Units Equipped with DC Spark Boxes* *For installation of the DC Spark Box refer to the LP Conversion instructions in this manual.
Page 40 - INSTALLING THE OPTIONAL FAN; TO REMOVE THE FAN
Regency ® P48-2 Zero Clearance Direct Vent Gas Fireplace 40 INSTALLATION INSTALLING THE OPTIONAL FAN 120 Volt AC power is needed for the fan switch and blower. The fan can be hard wired if desired. The receptacle box should be installed on the left hand side of the unit by a qualifi ed electrician. T...
Page 41 - OPERATING INSTRUCTIONS
Regency ® P48-2 Zero Clearance Direct Vent Gas Fireplace 41 OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS 1) Read and understand these instructions before operating this appliance. 2) Check to see that all wiring is correct and enclosed to prevent possible shock. 3) Check to ensure there are no gas ...
Page 42 - Copy of the Lighting Plate Instructions; NORMAL OPERATING
Regency ® P48-2 Zero Clearance Direct Vent Gas Fireplace 42 Copy of the Lighting Plate Instructions NORMAL OPERATING SOUNDS OF GAS APPLIANCES It is possible that you will hear some sounds from your gas appliance. This is perfectly normal due to the fact that there are various gauges and types of ste...
Page 43 - MAINTENANCE
Regency ® P48-2 Zero Clearance Direct Vent Gas Fireplace 43 MAINTENANCE INSTRUCTIONS 1) Always turn off the gas valve before cleaning. For relighting, refer to lighting instructions. Keep the burner and control compartment clean by brushing and vacuuming at least once a year. When cleaning the logs,...
Page 44 - BAY GLASS REPLACEMENT; DOOR GLASS; GLASS REPLACEMENT; INSTALLING VALVE
Regency ® P48-2 Zero Clearance Direct Vent Gas Fireplace 44 C A U T I O N : W e a r g l o v e s w h e n r e m o v i n g d a m a g e d o r b r o k e n glass. BAY GLASS REPLACEMENT 1) Remove the door from the unit and place on a soft surface to prevent scratching. 2) Remove the nuts holding the glass ...
Page 45 - REMOVING VALVE
Regency ® P48-2 Zero Clearance Direct Vent Gas Fireplace 45 MAINTENANCE 6) Remove the burner by removing the screw on the left side and then slide the burner to the left and lift out. 7) Remove the right and left side defl ectors by removing the 2 screws on each defl ector. REMOVING VALVE 1) Shut off ...
Page 46 - PARTS LIST; MAIN ASSEMBLY
Regency ® P48-2 Zero Clearance Direct Vent Gas Fireplace 46 PARTS LIST MAIN ASSEMBLY Part # Description Part # Description 1) 948-259 Door Handle 3) 948-046 Chain4) 948-115 Spring6) 430-129 Receptacle Box Mount 7) 910-429 Box - Receptacle 8) 910-428 Duplex Receptacle 9) 910-430 Cover - Receptacle 10...
Page 48 - BURNER & LOG ASSEMBLY
Regency ® P48-2 Zero Clearance Direct Vent Gas Fireplace 48 PARTS LIST BURNER & LOG ASSEMBLY Part # Description 370-574/P Valve Assembly - Natural Gas 370-576/P Valve Assembly - Propane 52) * Gasket - Valve Access Plate 56) 910-190 Piezo Ignitor & Nut 57) 910-478 Valve S.I.T. - Natural Gas /...
Page 51 - WARRANTY
Regency ® P48-2 Zero Clearance Direct Vent Gas Fireplace 51 WARRANTY Regency Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each unit thoroughly before it leaves our facility. FPI Fireplace Products Interna...
Page 52 - Installer: Please complete the following information; Printed in Canada; Register your Regency
Regency ® P48-2 Zero Clearance Direct Vent Gas Fireplace 52 Installer: Please complete the following information Dealer Name & Address: ______________________________________________ ___________________________________________________________________ Installer: __________________________________...