Page 2 - INFORMATION FOR MOBILE/MANUFACTURED HOMES AFTER FIRST SALE
Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace 2 To the New Owner: Congratulations! You are the owner of a state-of-the-art Gas Stove by FIREPLACE PRODUCTS INTERNATIONAL. The P33R-2 is a hand crafted appliance and has been designed to provide you with all the warmth and charm of a...
Page 3 - TABLE OF CONTENTS
Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace 3 TABLE OF CONTENTS Operating Instructions Lighting Plate Instructions ......................................... 28Operating Instructions ............................................... 29Lighting Procedure ..............................
Page 4 - SAFETY LABEL
Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace 4 This is a copy of the label that accompanieseach P33R-2 Zero Clearance Direct Vent GasFireplace. We have printed a copy of the con-tents here for your review. The safety label islocated on the front inside base of the unit,visible w...
Page 5 - INSTALLATION
Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace 5 INSTALLATION IMPORTANT: SAVE THESE INSTRUCTIONS The P33R-NG2 or P33R-LP2 Direct Vent Fire-place must be installed in accordance with theseinstructions. Carefully read all the instructions inthis manual first. Consult the "author...
Page 7 - COMBUSTIBLE MANTELS; MANTEL LEG CLEARANCES; CLEARANCES
Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace 7 COMBUSTIBLE MANTELS INSTALLATION Clearances for Bay or Flush Front WARNINGFire hazard is an extreme risk ifthese clearances are not ad-hered to. Because of the extreme heat this fireplace emits, the mantel clearances are critical.Co...
Page 8 - FRAMING AND FINISHING
Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace 8 INSTALLATION Install Side Nailing Strips, and Top FacingS u p p o r t b e f o r e u n i t i s s l i p p e d i n t oposition. See page 9 for assemblydetails. 3 ) For exterior walls, insulate the enclosure to the same degree as the re...
Page 9 - Top Standoff Assembly; UNIT ASSEMBLY
Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace 9 "C" Screw Position:For a facing material depth of1-1/4"(32mm), the top facingsupport must be reversed. The Top Facing Support, the Side Nailing Stripsand the 2 Top Standoffs must be correctlypositioned and attached to th...
Page 10 - EXTERIOR VENT TERMINATION LOCATIONS
Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace 10 EXTERIOR VENT TERMINATION LOCATIONS INSTALLATION . B B B B A C V V V V V V V A A V Fixed Fixed Openable Closed Closed Openable N L B E B M D F K H j V ertical Termination V V ent terminal Area where terminal is not permited A Air s...
Page 11 - VENTING INTRODUCTION; HORIZONTAL TERMINATIONS ONLY; Alternate
Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace 11 INSTALLATION VENTING INTRODUCTION The P33R-2 uses the "balanced flue" technology Co Axial system. The inner liner vents products of combustion to the outside while the outerliner draws outside combustion air into the combus...
Page 12 - INSTALLATION PROCEDURES
Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace 12 INSTALLATION PROCEDURES for Regency Direct Vent System (Flex) Minimum and Maximum Vent Clearances INSTALLATION 1 ) Locate the unit in the framing, rough in the gas (preferably on the right side of the unit)and the electrical (Junct...
Page 13 - SIMPSON DURA-VENT VENTING COMPONENTS LIST; Direct Vent GS; SIMPSON DURA-VENT VENTING; Horizontal or Vertical Terminations
Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace 13 SIMPSON DURA-VENT VENTING COMPONENTS LIST All Simpson Dura-Vent components are available directly from Regency. All components available directly from Regency. Part # Description Part # Description Part # Description INSTALLATION S...
Page 14 - VENTING ARRANGEMENTS - HORIZONTAL TERMINATIONS; SIMPSON DURA-VENT DIRECT VENT GS SYSTEM
Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace 14 VENTING ARRANGEMENTS - HORIZONTAL TERMINATIONS SIMPSON DURA-VENT DIRECT VENT GS SYSTEM or Regency Direct Vent (Flex) for Horizontal Terminations (Propane & Natural Gas) INSTALLATION (Dura-Vent System or Regency DV Flex) The dia...
Page 15 - VENTING ARRANGEMENTS - VERTICAL TERMINATIONS; SIMPSON DURA-VENT DIRECT VENT GS SYSTEM
Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace 15 INSTALLATION • Vent must be supported at offsets • Firestops are required at each floor level and whenever passing through a wall. • Maintain a 1-1/4" clearance to combustibles Note: Must use optional flue adapter when using Si...
Page 16 - VERTICAL TERMINATION
Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace 16 VERTICAL TERMINATION WITH CO-LINEAR FLEX SYSTEM THE APPLIANCE MUST NOT BE CONNECTED TO A CHIMNEY FLUE SERVING A SEPARATE SOLID FUEL BURNING APPLIANCE. This appliance is designed to be attached to two3" (76mm) co-linear aluminiu...
Page 17 - Venting Arrangements - Vertical Terminations
Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace 17 Venting Arrangements - Vertical Terminations with Co-linear Flex System for both Residential & Manufactured Homes into Masonry Fireplaces The shaded area in the diagrams showthe allowable vertical terminations. INSTALLATION
Page 18 - HORIZONTAL INSTALLATIONS
Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace 18 INSTALLATION Diagram 3 HORIZONTAL INSTALLATIONS Diagram 1 b ) Horizontal runs of vent must be sup- ported every three feet. Wall straps areavailable for this purpose. 5 ) Mark the wall for a 10" x 10" square hole. The cente...
Page 19 - GAS LINE; VERTICAL
Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace 19 INSTALLATION GAS LINE INSTALLATION The gas line can be brought through either theright or the left side of the appliance. The gasvalve is situated on the right hand side of the unitand the gas inlet is on the right hand side of the...
Page 20 - PILOT ADJUSTMENT; HIGH ELEVATION
Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace 20 P33R-2 System Data For 0 to 4500 feet altitudeBurner Inlet Orifice Sizes: Natural Gas Propane Burner #45 #54 Max. Input Rating - Natural Gas 21,000 Btu/h - Propane 21,000 Btu/h Min. Input Rating -Natural Gas 10,500 Btu/h -Propane 1...
Page 21 - Conversion Kit from Natural Gas to Propane Model #431-969; THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER
Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace 21 INSTALLATION Conversion Kit from Natural Gas to Propane Model #431-969 for P33R-2 using SIT 820 NOVA Gas Valve THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !! Remove the 2 screws, pus...
Page 22 - OPTIONAL BRICK
Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace 22 INSTALLATION Note: The logs must not be in the unit. 3 ) Insert the back brick panel by carefully slipping it between the back wall of thefirebox and the rear log bracket. OPTIONAL BRICK PANELS 1 ) Undo the bottom 2 door latches an...
Page 23 - Optional Flush Trim
Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace 23 Diagram 1 Diagram 3 STANDARD FLUSH DOOR The standard flush door comes with a blackframe. To install the frame, simply hook the topdoor flange onto the top of the unit and swingthe door towards the unit, diagram 1. Be carefulthat th...
Page 24 - OPTIONAL BAY DOOR; The Bay louvers MUST be used; FLUSH LOUVERS; Optional Bay Trim; DOUBLE SCREEN
Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace 24 OPTIONAL BAY DOOR The Bay louvers MUST be used with the Bay glass option. The optional Bay door is an overlay on theflush front. The standard flush door and glassmust remain on the unit. 1 ) Hook the top of the bay door over the fl...
Page 25 - Thermostat Wire Table; CAUTION; CAUTION
Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace 25 INSTALLATION OPTIONAL WALL THERMOSTAT A wall thermostat may be installed if desired,connect the wires as per the wiring diagram.Use table below to determine the maximum wirelength. Note: Preferable if the thermostat is in- stalled ...
Page 26 - WIRING DIAGRAM
Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace 26 INSTALLATION CAUTION: Label all wiresprior to disconnectionwhen servicing controls.Wiring errors can causeimproper and dangerousoperation. Caution: Ensure that the wires donot touch any hot surfaces and areaway from sharp edges. WI...
Page 27 - INSTALLING THE OPTIONAL FAN
Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace 27 INSTALLATION INSTALLING THE OPTIONAL FAN 120 Volt AC power is needed for the fan switchand blower. The fan can be hard wired ifdesired. The receptacle box should be installedon the left hand side of the unit by a qualifiedelectrici...
Page 28 - OPERATING INSTRUCTIONS; COPY OF THE LIGHTING PLATE INSTRUCTIONS; DO NOT REMOVE THIS INSTRUCTION PLATE
Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace 28 OPERATING INSTRUCTIONS COPY OF THE LIGHTING PLATE INSTRUCTIONS TO TURN OFF GAS APPLIANCE FOR YOUR SAFETY READ BEFORE LIGHTING This appliance must be installed in accordance with local codes, if any; if not, follow the current CAN1-...
Page 30 - MAINTENANCE; General Vent Maintenance
Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace 30 MAINTENANCE MAINTENANCE INSTRUCTIONS 1 ) Always turn off the gas valve before clean- ing. For relighting, refer to lighting instruc-tions. Keep the burner and control compart-ment clean by brushing and vacuuming atleast once a year...
Page 31 - THERMOCOUPLE; GLASS GASKET; Flush Glass Replacement
Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace 31 MAINTENANCE THERMOPILE/ THERMOCOUPLE 1 ) Open the bottom louvers. 2 ) Loosen the thermocouple or thermopile with a 7/16" wrench. 3 ) Disconnect thermocouple by loosening nut from the valve with a 9mm wrench. Discon-nect thermop...
Page 32 - REMOVING VALVE; INSTALLING VALVE
Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace 32 gram 2) and then lift the entire assembly out(diagram 3). 10) Undo the pilot tube from the valve with a 7/16" wrench. REMOVING VALVE 1 ) Shut off the gas supply. 2 ) Remove the louvers (and bay door if it is on). 3 ) Open the f...
Page 33 - PARTS LIST; Main Assembly
Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace 33 PARTS LIST Main Assembly Part # Description Part # Description Part # Description 1 ) 948-247 Door Handle 2 ) * Thermodisc Bracket 7 ) 910-428 Duplex Receptacle 8 ) 910-429 Box - Receptacle 9 ) 910-430 Cover - Receptacle 10) 904-68...
Page 34 - Burner & Log Assembly
Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace 34 Burner & Log Assembly Part # Description 53) 430-055 Gasket - Valve Access Plate - NG/LP 54) 910-421 Pilot ON/OFF Extension Knob 55) 910-422 Flame HI/LOW Extension Knob 56) 910-190 Piezo Ignitor and Nut 432-574/P Valve Assy - N...
Page 35 - Flush Front & Louvers
Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace 35 PARTS LIST Flush Front & Louvers Part # Description Part # Description 117) 904-196 Magnet - 1' round 130) 430-924 Flush Glass Trim (set) - Gold (Option) 131) 430-926 Flush Glass Trim (set) - Brass (Option) 430-947 Flush Glass ...
Page 37 - NOTES
Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace 37 _____________________________________________________________________________________ ____________________________________________________________ __________________________________________________________ _________________________...
Page 39 - WARRANTY
Regency P33R-2 Zero Clearance Rear Vent Direct Vent Gas Fireplace 39 WARRANTY Regency Fireplace Products, are designed with reliability and simplicity in mind. In addition, our internal Quality AssuranceTeam carefully inspects each unit thoroughly before it leaves our door. Regency Industries Ltd. i...
Page 40 - Installer: Please complete the following information; Printed in Canada
Installer: Please complete the following information Dealer Name & Address: ______________________________________________ __________________________________________________________________ Installer: ___________________________________________________________ Phone #: __________________________...