Page 2 - INFORMATION FOR MOBILE/MANUFACTURED HOMES AFTER FIRST SALE; This Regency
Regency ® P33-4 Zero Clearance Direct Vent Gas Fireplace 2 To the New Owner: Congratulations! You are the owner of a state-of-the-art Gas Fireplace by FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. The P33-4 has been designed to provide you with all the warmth and charm of a wood fi replace at the fl ick o...
Page 3 - TABLE OF CONTENTS
Regency ® P33-4 Zero Clearance Direct Vent Gas Fireplace 3 TABLE OF CONTENTS Full Screen doors .......................................................34Optional Wall Thermostat ..........................................36Optional Remote Control ............................................36Optional ...
Page 4 - SAFETY LABEL
Regency ® P33-4 Zero Clearance Direct Vent Gas Fireplace 4 SAFETY LABEL This is a copy of the label that accompanies each P33-4 Zero Clearance Direct Vent Gas Fireplace. We have printed a copy of the contents here for your review. The safety label is located on the front inside base of the unit, vis...
Page 5 - REQUIREMENTS; MA Code - CO Detector
Regency ® P33-4 Zero Clearance Direct Vent Gas Fireplace 5 REQUIREMENTS 5.08: Modifications to NFPA-54, Chapter 10 (2) Revise 10.8.3 by adding the following additional requirements: (a) For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used...
Page 6 - INSTALLATION; SAVE THESE
Regency ® P33-4 Zero Clearance Direct Vent Gas Fireplace 6 INSTALLATION IMPORTANT MESSAGE SAVE THESE INSTRUCTIONS The P33-NG4 or P33-LP4 Direct Vent Fireplace must be installed in accordance with these instructions. Carefully read all the instructions in this manual fi rst. Consult the "authority...
Page 8 - COMBUSTIBLE MANTELS; MANTEL LEG CLEARANCES; WARNING
Regency ® P33-4 Zero Clearance Direct Vent Gas Fireplace 8 COMBUSTIBLE MANTELS Because of the extreme heat this fi replace emits, the mantel clearances are critical. Combustible mantel clearances from top of unit are shown in the diagram below. Note: A non-combustible mantel may be installed at a low...
Page 9 - FRAMING AND FINISHING
Regency ® P33-4 Zero Clearance Direct Vent Gas Fireplace 9 INSTALLATION 3) For exterior walls, insulate the enclosure to the same degree as the rest of the house, apply vapour barrier and drywall, as per local installation codes. (Do not insulate the fi replace itself.) 4) The top of the unit must no...
Page 10 - UNIT ASSEMBLY PRIOR TO INSTALLATION; VENTING INTRODUCTION
Regency ® P33-4 Zero Clearance Direct Vent Gas Fireplace 10 The Top Facing Support, the Side Nailing Strips and the 2 Top Standoffs must be correctly positioned and attached to the top before the unit is put into position. Top Standoff Assembly The top standoffs are shipped in a fl at position and mu...
Page 11 - EXTERIOR VENT TERMINATION LOCATIONS
Regency ® P33-4 Zero Clearance Direct Vent Gas Fireplace 11 EXTERIOR VENT TERMINATION LOCATIONS INSTALLATION A= Clearance above grade, veranda, porch, deck, or balcony *(min. 12"/30cm) B= Clearance to window or door that may be opened *(12"/30cm) #(9"/23cm) C= Clearance to permanently cl...
Page 12 - IMPORTANT; REGENCY; Horizontal Terminations Only; MINIMUM; Alternate
Regency ® P33-4 Zero Clearance Direct Vent Gas Fireplace 12 IMPORTANT If using any Cabinet Mantels with Part # 510956, 510958, 510962, 510964 and 510834 the wall thimble must be secured fi rst and venting must be attached to unit before sliding into fi nal position. Also Rigid Vent venting cannot be u...
Page 13 - INSTALLATION PROCEDURES; for Regency
Regency ® P33-4 Zero Clearance Direct Vent Gas Fireplace 13 Termination Cap Wall Thimble 2 pieces (10" (254mm) Outer Diameter) 2” x 4” or 2” x 6” (21mm x 102mm or 21mm x 152mm) 6-7/8" (175mm) dia. air intake 4" (102mm) dia. flue pipe with spring spacer Screws (4 per connection) Screws (3...
Page 14 - RIGID PIPE VENTING SYSTEMS; Horizontal or Vertical Terminations; Flat Wall Installation
Regency ® P33-4 Zero Clearance Direct Vent Gas Fireplace 14 Pipe Length Vertical Terminal Storm Collar Flashing Ceiling Firestop 24" Length Adj.Pipe Length 11" - 14-5/8” 90 Elbow o Horizontal Termination Cap # 946-523 Wall Thimble Vinyl Siding Standoff (Optional) Rigid Pipe Adapter # 510-994...
Page 15 - RIGID PIPE VENTING COMPONENTS LIST
Regency ® P33-4 Zero Clearance Direct Vent Gas Fireplace 15 FPI946-506/P Vent Guard (Optional) 510-994 Rigid Pipe Adaptor (Must use with all Rigid Piping) 640-530/P Riser Vent Terminal 946-205 Vinyl Siding Shield for Riser Vent Terminal 946-208/P Vent Guard (Optional) - Riser Vent Terminal 946-523/P...
Page 16 - RIGID PIPE VENTING ARRANGEMENTS; Vertical Terminations
Regency ® P33-4 Zero Clearance Direct Vent Gas Fireplace 16 INSTALLATION • Vent must be supported at offsets.• Firestops are required at each fl oor level and whenever passing through a wall.• Maintain clearances to combustibles. Note: Must use optional rigid pipe adapter when using rigid vent system...
Page 18 - Horizontal Terminations; Minimum
Regency ® P33-4 Zero Clearance Direct Vent Gas Fireplace 18 RIGID PIPE VENTING ARRANGEMENTS Horizontal Terminations REGENCY ® DIRECT VENT SYSTEM (FLEX) (Propane & Natural Gas) This diagram shows all allowable combinations of vertical runs with horizontal terminations, using one 45 o and one 90 o...
Page 19 - Elbows; Option; Option
Regency ® P33-4 Zero Clearance Direct Vent Gas Fireplace 19 Horizontal Venting with Two (2) 90 o Elbows Horizontal Venting with Two (2) 90 o Elbows Horizontal Venting with Three (3) 90 o Elbows INSTALLATION One 90 o elbow = Two 45 o elbows. Option V H + H1 With these options, maximum total pipe leng...
Page 21 - Option V
Regency ® P33-4 Zero Clearance Direct Vent Gas Fireplace 21 INSTALLATION Vertical Venting with Three (3) 90 o Elbows Vertical Venting with Three (3) 90 o Elbows Option H V H + H1 V + V1 A) 1' Max. 1' Min. 3' Max. 3' Min. B) 2' Max. 2' Min. 4' Max. 5' Min. C) 3' Max. 3' Min.' 5' Max. 7' Min. D) 4' Ma...
Page 22 - VERTICAL TERMINATION
Regency ® P33-4 Zero Clearance Direct Vent Gas Fireplace 22 Flex Liner Exhaust Flue A maximum of two certified joiner kits may be used per length. #948-305 35 ft (11m) Air Intake Co-linear DV Vertical Termination Cap # 946-529 Co-Linear Flex Adapter with Kit# 946-563 Outer Pipe with Kit# 946-563 Inn...
Page 23 - VENTING ARRANGEMENTS - VERTICAL TERMINATIONS; into Masonry Fireplaces; ertical
Regency ® P33-4 Zero Clearance Direct Vent Gas Fireplace 23 VENTING ARRANGEMENTS - VERTICAL TERMINATIONS with Co-linear Flex System for bothResidential & Manufactured Homes into Masonry Fireplaces The shaded area in the diagrams show the allowable vertical terminations. INSTALLATION 8' (2.4m) Mi...
Page 24 - UNIT INSTALLATION WITH HORIZONTAL TERMINATION; Snorkel
Regency ® P33-4 Zero Clearance Direct Vent Gas Fireplace 24 Riser Vent Termination Min. 6-1/4"* (159mm) INSTALLATION Diagram 3 UNIT INSTALLATION WITH HORIZONTAL TERMINATION Diagram 1 b) H o r i z o n t a l r u n s o f v e n t m u s t b e supported every three feet. Wall straps are available for ...
Page 25 - GAS LINE; UNIT INSTALLATION
Regency ® P33-4 Zero Clearance Direct Vent Gas Fireplace 25 INSTALLATION GAS LINE INSTALLATION The gas line is brought through the right side of the appliance. The gas valve is situated on the right hand side of the unit and the gas inlet is on the right hand side of the valve. The gas line connecti...
Page 26 - HIGH ELEVATION; PILOT ADJUSTMENT
Regency ® P33-4 Zero Clearance Direct Vent Gas Fireplace 26 GAS PIPE PRESSURE TESTING The appliance must be isolated from the gas supply piping system by closing its individual manual shut-off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1...
Page 27 - Burner Orifi ce; Note: Use a magnetic type
Regency ® P33-4 Zero Clearance Direct Vent Gas Fireplace 27 INSTALLATION Each Kit contains one LPG Conversion Kit and one DCSparker Kit. LPG Conversion Kit Contains:Qty. Part # Description 1 904-163 Burner Orifi ce #54 1 918-590 Decal "Converted to LPG" 1 908-528 Red "LPG" label 1 904...
Page 29 - Installation of the DC Sparker
Regency ® P33-4 Zero Clearance Direct Vent Gas Fireplace 29 INSTALLATION 4) Install the 3/4" nylon plug to cover up the hole on the mounting bracket. 5) Connect the DC spark generator wires to the SIT Valve with the screw, which is provided in the kit. 6) Locate the ground lug at the receptical ...
Page 31 - OPTIONAL FLUSH
Regency ® P33-4 Zero Clearance Direct Vent Gas Fireplace 31 Diagram 1 Diagram 3 STANDARD FLUSH DOOR The standard fl ush door comes with a black frame. To install the frame, simply hook the top door fl ange onto the top of the unit and swing the door towards the unit, diagram 1. Be careful that the gla...
Page 32 - OPTIONAL BAY DOOR; The Bay louvers MUST be used; FLUSH LOUVERS; OPTIONAL BAY TRIM
Regency ® P33-4 Zero Clearance Direct Vent Gas Fireplace 32 OPTIONAL BAY DOOR The Bay louvers MUST be used with the Bay glass option. The optional Bay door is an overlay on the fl ush front. The standard fl ush door and glass must remain on the unit. 1) Hook the top of the bay door over the fl ush door...
Page 33 - BAY LOUVERS
Regency ® P33-4 Zero Clearance Direct Vent Gas Fireplace 33 6) Open the bottom louver. Pull the Burner ON/OFF control box from inside the bottom of the fi replace and position the slots in the bracket over the 2 screws on the left side of the bottom louver. Push down to lock into place. Tighten the s...
Page 34 - FULL SCREEN DOORS
Regency ® P33-4 Zero Clearance Direct Vent Gas Fireplace 34 FULL SCREEN DOORS 1) Before beginning the installation, remove the Glass Door from the unit. Refer to the manual for instructions. 2) Slide the Bottom Faceplate Bracket into the bottom of the unit, secure it into the pins located on the ins...
Page 36 - CAUTION; Thermostat Wire Table; CAUTION
Regency ® P33-4 Zero Clearance Direct Vent Gas Fireplace 36 Optional WALL SWITCH 1) Run the supplied 15' of wire through the right or left side gas inlet opening. Be careful not to damage wire. Note: We recommend a maximum of 15' of wire but if you wish to go with a longer run, use the Thermostat Wi...
Page 37 - WIRING DIAGRAMS; For; NATURAL GAS; Units and Units; NOT; Equipped with DC Spark Boxes
Regency ® P33-4 Zero Clearance Direct Vent Gas Fireplace 37 WIRING DIAGRAMS This heater does not require a 120V A.C. supply for operation. In case of a power failure, the burner switch and the optional remote control/thermostat will continue to operate. However, a 120V A.C. power supply is needed fo...
Page 38 - PROPANE; Units and Units Equipped with DC Spark Boxes*
Regency ® P33-4 Zero Clearance Direct Vent Gas Fireplace 38 Caution: Ensure that the wires do not touch any hot surfaces and are away from sharp edges. CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. INSTALLATION For ...
Page 39 - INSTALLING THE OPTIONAL FAN; TO REMOVE THE FAN
Regency ® P33-4 Zero Clearance Direct Vent Gas Fireplace 39 INSTALLING THE OPTIONAL FAN 120 Volt AC power is needed for the fan switch and blower. The fan can be hard wired if desired. The receptacle box should be installed on the left hand side of the unit by a qualifi ed electrician. The neutral (w...
Page 40 - OPERATING INSTRUCTIONS; COPY OF THE LIGHTING PLATE INSTRUCTIONS
Regency ® P33-4 Zero Clearance Direct Vent Gas Fireplace 40 OPERATING INSTRUCTIONS COPY OF THE LIGHTING PLATE INSTRUCTIONS Gas Inlet OFF Gas Inlet
Page 42 - MAINTENANCE
Regency ® P33-4 Zero Clearance Direct Vent Gas Fireplace 42 MAINTENANCE MAINTENANCE INSTRUCTIONS 1) Always turn off the gas valve before cleaning. For relighting, refer to lighting instructions. Keep the burner and control compartment clean by brushing and vacuuming at least once a year. When cleani...
Page 43 - THERMOCOUPLE; Flush Glass Replacement; Bay Glass Replacement
Regency ® P33-4 Zero Clearance Direct Vent Gas Fireplace 43 MAINTENANCE THERMOPILE/ THERMOCOUPLE 1) Open the bottom louvers. 2) Loosen the thermocouple or thermopile with a 7/16" wrench. 3) Disconnect thermocouple by loosening nut from the valve with a 9mm wrench. Disconnect thermopile by loosen...
Page 44 - REMOVING VALVE; INSTALLING VALVE
Regency ® P33-4 Zero Clearance Direct Vent Gas Fireplace 44 REMOVING VALVE 1) Shut off the gas supply. 2) Remove the louvers (and bay door if it is on). 3) Open the fl ush door and remove the door. 4) Remove the logs. 5) Remove the burner/grate assembly by removing the two Phillips head screws and th...
Page 45 - PARTS LIST; MAIN ASSEMBLY; Part # Description
Regency ® P33-4 Zero Clearance Direct Vent Gas Fireplace 45 PARTS LIST MAIN ASSEMBLY Part # Description Part # Description Part # Description 1) 948-247 Door Handle 2) * Thermodisc Bracket 7) 910-428 Duplex Receptacle 8) 910-429 Box - Receptacle 9) 910-430 Cover - Receptacle 10) 904-687 Clamp Connec...
Page 47 - BURNER & LOG ASSEMBLY; Part
Regency ® P33-4 Zero Clearance Direct Vent Gas Fireplace 47 BURNER & LOG ASSEMBLY Part Description 53) 430-055 Gasket - Valve Access Plate - NG/LP 54) 910-421 Pilot ON/OFF Extension Knob 55) 910-422 Flame HI/LOW Extension Knob 56) 910-190 Piezo Ignitor and Nut 433-574/P Valve Assy - Natural Gas ...
Page 48 - FLUSH FRONT & LOUVERS
Regency ® P33-4 Zero Clearance Direct Vent Gas Fireplace 48 PARTS LIST FLUSH FRONT & LOUVERS Part # Description Part # Description 117) 904-196 Magnet - 1' round 130) 430-924 Flush Glass Trim (set) - Gold (Option) 131) 430-926 Flush Glass Trim (set) - Brass (Option) 430-947 Flush Glass Trim (set...
Page 50 - NOTES
Regency ® P33-4 Zero Clearance Direct Vent Gas Fireplace 50 NOTES __________________________________________________ __________________________________________________ __________________________________________________ __________________________________________________ ______________________________...
Page 51 - WARRANTY
Regency ® P33-4 Zero Clearance Direct Vent Gas Fireplace 51 WARRANTY Regency ® Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each unit thoroughly before it leaves our facility. FPI Fireplace Products Inter...
Page 52 - Installer: Please complete the following information; Printed in Canada
Regency ® P33-4 Zero Clearance Direct Vent Gas Fireplace 52 Installer: Please complete the following information Dealer Name & Address: ______________________________________________ ___________________________________________________________________ Installer: __________________________________...