Page 2 - REGENCY; TO THE NEW OWNER; UNIT DIMENSIONS
2 Regency IG34 Gas Inbuilt Fireplace REGENCY GAS INBUILT FIREPLACE TO THE NEW OWNER Congratulations! You are the owner of a state-of-the-art Gas Inbuilt Fireplace by FPI. The Regency Gas Fireplace Series of appliances has been designed to provide you with all the warmth and charm of a fi replace, at...
Page 3 - TABLE OF CONTENTS; DATA BADGE
3 Regency IG34 Gas Inbuilt Fireplace TABLE OF CONTENTS DATA BADGE Copy of Data Badge ..................................................... 4 INSTALLATION Important Message ........................................................ 5For Your Safety .........................................................
Page 4 - Regency Gas Fireplace; Gas Type; Model
4 Regency IG34 Gas Inbuilt Fireplace DATA BADGE (Australia Only) This is a copy of the label that accompanies each Regency IG34 Gas Inbuilt fi replace. We have printed a copy of the contents here for your review. DATA BADGE NOTE: Regency units are constantly being improved. Check the label on the un...
Page 5 - INSTALLATION; WARNING
5 Regency IG34 Gas Inbuilt Fireplace INSTALLATION IMPORTANT MESSAGE The Regency Gas Inbuilt must be installed in accordance with these instructions. Carefully read all the instructions in this manual fi rst. Note: Failure to follow these instructions could cause a malfunction of the heater which cou...
Page 7 - GAS PIPE PRESSURE; FLUE LINER
7 Regency IG34 Gas Inbuilt Fireplace INSTALLATION GAS PIPE PRESSURE TESTING The appliance must be isolated from the gas supply piping system by closing its individual manual shut-off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig. (...
Page 8 - INSTALLATION IN MASONRY OR ZERO CLEARANCE CHIMNEY
8 Regency IG34 Gas Inbuilt Fireplace INSTALLATION INSTALLATION IN MASONRY OR ZERO CLEARANCE CHIMNEY 1) Measure and record dimensions to determine total Flex Liner length requirements (see instructions below for details). 2) Carefully feed the liner down the chimney (masonry or zero clearance) and ou...
Page 9 - AERATION SETTINGS; System Data
9 Regency IG34 Gas Inbuilt Fireplace AERATION SETTINGS The burner aeration is factory set but may need adjusting due to either the local gas supply, air supply or altitude. This adjustment is performed by the installer. (Close the aeration for a more yellow fl ame, or open it to make the fl ame blue...
Page 10 - Conversion Kit #486-968 for NG to LPG Model; THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER
10 Regency IG34 Gas Inbuilt Fireplace INSTALLATION Conversion Kit #486-968 for NG to LPG Model THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !! C onversion Kit 486-968 Contains: Qty. Part # Description1 904-345 Burner Orifi ce #511 918-273 Red "LPG&...
Page 11 - 9) Adjusting the Outlet Pressure; The outlet pressure must be set to minimum 1.6
11 Regency IG34 Gas Inbuilt Fireplace INSTALLATION Installer Notice: These instructions must be left with the appliance. After carrying out all adjustments, block the setting screws with paint, taking care not to obstruct the breather orifi ce of the pressure. Put back the modulator plastic cap. WAR...
Page 14 - OPTIONAL STAINLESS STEEL INNER PANEL INSTALL
14 Regency IG34 Gas Inbuilt Fireplace INSTALLATION OPTIONAL STAINLESS STEEL INNER PANEL INSTALL Before you start: Stainless panels must be inspected for scratches and dimples prior to installation. All claims to be recorded at this time. Claims for damage after installation will not receive consider...
Page 15 - LOG SET INSTALLATION; Note: Install Optional Brick Panels prior to installing logs.; do not
15 Regency IG34 Gas Inbuilt Fireplace INSTALLATION LOG SET INSTALLATION Read the instructions below carefully and refer to the diagrams. If logs are broken do not use the unit until they are replaced. Broken logs can interfere with the pilot operation. The gas log kit contains the following: a) 02-4...
Page 16 - Place the Left Top Log D)02-46 on the pin on Log
16 Regency IG34 Gas Inbuilt Fireplace INSTALLATION Logs D)02-46 and E)02-47 in position. 6) Place the Left Top Log D)02-46 on the pin on Log C)02-56 and on top of the cutout on Log A)02-43. 7) Place the notch in Center Log E)02-47 over Log B)02- 45 and across the cutout on Log A)02-43. Cutout Pin Cu...
Page 17 - Place the embers and Rockwool on the exposed front; Test fi re to ensure proper light off (make sure fl ame
17 Regency IG34 Gas Inbuilt Fireplace INSTALLATION 10) Place the embers and Rockwool on the exposed front burner tray. 9) Place Front Left Log G)02-44 onto the 2 front pins as shown. G)02-44 F)02-48 B)02-45 Bracket A)02-43 Front edge of rear burner The bottom right edge of Log F)02-48 must sit snugl...
Page 18 - GLASS DOOR INSTALLATION
18 Regency IG34 Gas Inbuilt Fireplace INSTALLATION GLASS DOOR INSTALLATION STANDARD FLUSH DOOR The standard fl ush door comes with a black frame. To install the frame and glass door, simply hook the top door fl ange onto the top of the unit and swing the door towards the unit, diagram 1. Be careful ...
Page 19 - SCREEN INSTALLATION; Plinth Trim Option; Install faceplate on unit - see next page.; FACEPLATE & OPTIONAL PLINTH TRIM ASSEMBLY
19 Regency IG34 Gas Inbuilt Fireplace INSTALLATION SCREEN INSTALLATION Plinth Trim Option : Plinth Trim Kits are an option that can be used to fi nish off the installation when the bottom of the fi replace is higher than the hearth or to raise the fi replace. 1) Lay the faceplate side panels fl at, ...
Page 20 - Note; FACEPLATE AND DOOR FRAME INSTALLATION
20 Regency IG34 Gas Inbuilt Fireplace INSTALLATION Note: Ensure that the fl anges on the sides of the fi rebox are on the outside, when installing the faceplate (see below). Faceplate Flange on fi rebox Door Frame Glass Door Metal Lip Openings on hinge 3) Fold down the 2 hinges on the bottom frame t...
Page 21 - THERMODISC INSTALLATION
21 Regency IG34 Gas Inbuilt Fireplace INSTALLATION Back of Faceplate Back of Faceplate Bracket Thermodisc 1) Install faceplate and door frame as per previous page. 2) After faceplate has been installed - place the touch pad (facing out) in the knockout located on the left side of the faceplate. 3) S...
Page 22 - FINAL CHECK; WIRING; STANDARD WIRING
22 Regency IG34 Gas Inbuilt Fireplace FINAL CHECK Before leaving this unit with the customer, the installer must ensure that the appliance is fi ring correctly. This includes: 1) Clocking the appliance to ensure the correct fi ring rate (rate noted on label) at 15 minutes. 2) If required, adjusting ...
Page 23 - OPERATING INSTRUCTIONS; Fan must be running at all times
23 Regency IG34 Gas Inbuilt Fireplace OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS Before operating this appliance, proceed through the following check list. 1) Read and understand these Instructions before operating this appliance. 2) Check to see that all wiring is correct and enclosed to prevent...
Page 24 - COPY OF LIGHTING INSTRUCTION PLATE; NORMAL OPERATING; DO NOT SPRAY AEROSOLS IN THE VICINITY OF; RESETTING THE UNIT
24 Regency IG34 Gas Inbuilt Fireplace COPY OF LIGHTING INSTRUCTION PLATE OPERATING INSTRUCTIONS NORMAL OPERATING SOUNDS OF GAS APPLIANCES It is possible that you will hear some sounds from your gas appliance. This is perfectly normal due to the fact that there are various gauges and types of steel u...
Page 25 - MAINTENANCE
25 Regency IG34 Gas Inbuilt Fireplace MAINTENANCE CAUTION: ANY SAFETY SCREEN OR GUARD REMOVED FOR SERV-ICING AN APPLIANCE MUST BE REPLACED PRIOR TO OPERAT-ING THE APPLIANCE. CLOTHING OR OTHER FLAM-MABLE MATERIAL SHOULD NOT BE PLACED ON OR NEAR THE APPLIANCE. DO NOT USE THIS APPLIANCE IF ANY PART HAS...
Page 26 - FAN MAINTENANCE
26 Regency IG34 Gas Inbuilt Fireplace MAINTENANCE FAN MAINTENANCE To Remove Fan: 1) Turn the unit off and allow it to cool to room temperature, 2) Unplug or disconnect power source to stove. 3) Open the bottom louvre. 4) Remove screws that secure protective screen. 5) Remove door frame and screen 6)...
Page 27 - VALVE ASSEMBLY REPLACEMENT
27 Regency IG34 Gas Inbuilt Fireplace MAINTENANCE 1) Unplug or disconnect the power source to the stove and shut off gas supply. 2) open bottom louvre and remove protective screen. 3) Remove the door frame and safety screen. 4) Remove the glass door, logs, and black or stainless inner liner, if inst...
Page 28 - PARTS LIST; ELECTRONIC COMPONENTS PARTS LIST
28 Regency IG34 Gas Inbuilt Fireplace PARTS LIST ELECTRONIC COMPONENTS PARTS LIST 910-936 910-082 910-088 910-089 910-084 910-527910-935 910-080 910-521, 910-522, 910-523, 910-525 910-912 910-906 910-514 910-083910-916 FG37 FG38 FG39 PG33 PG36 HG35 PG121/PG131 IG35 IG34 PG36D 910-909 Fan Resistor 91...
Page 29 - MAIN ASSEMBLY
29 Regency IG34 Gas Inbuilt Fireplace MAIN ASSEMBLY Part # Description Part # Description 1) 910-169/P Fan Motor (240 V)** 2) 910-995 Thermodisc** 3) 486-968 LPG Conversion Kit** 486-967 ULPG Conversion Kit** 4) 336-574/P Valve Assembly - NG 336-576/P Valve Assembly - LPG 5) 910-080 SIGMA Valve 845 ...
Page 30 - FACEPLATE ASSEMBLY
30 Regency IG34 Gas Inbuilt Fireplace PARTS LIST FACEPLATE ASSEMBLY Part # Description 14) 336-914 Faceplate & Trim Complete - Regular 15) 366-942 Plinth Kit 16) 336-532 Flush Screen Door** *Not available as a replacement part. 14 15
Page 31 - WARRANTY
31 Regency IG34 Gas Inbuilt Fireplace WARRANTY Regency ® Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each unit thoroughly before it leaves our door. Regency® is pleased to extend this limited lifetime wa...