Page 2 - FPI FIREPLACE PRODUCTS INTERNATIONAL LTD.; The Regency; has been designed to provide you with all the warmth and charm
2 Regency ® E21-2 Gas Fireplace Insert CONGRATULATIONS! You are the owner of a state-of-the-art Gas Insert by: FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. The Regency ® Gas Fireplace Series has been designed to provide you with all the warmth and charm of a fi replace, at the fl ick of a switch. The mod...
Page 3 - E21 GAS INSERT; TABLE OF CONTENTS
3 Regency ® E21-2 Gas Fireplace Insert E21 GAS INSERT TABLE OF CONTENTS SAFETY LABEL Serial No. Decal ........................................................... 4 REQUIREMENTS MA Code - CO Detector(for state of Massachusetts only) .................................. 5 INSTALLATION Important Message ...
Page 4 - SAFETY LABEL
4 Regency ® E21-2 Gas Fireplace Insert SAFETY LABEL This is a copy of the label that accompanies each Regency ® Gas Insert. We have printed a copy of the contents here for your review. The safety label is located on the front inside base of the unit visible when the bottom louver is open. Note: Rege...
Page 5 - REQUIREMENTS; MA Code - CO Detector
5 Regency ® E21-2 Gas Fireplace Insert REQUIREMENTS 5.08: Modifications to NFPA-54, Chapter 10 (2) Revise 10.8.3 by adding the following additional requirements: (a) For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part...
Page 6 - INSTALLATION
6 Regency ® E21-2 Gas Fireplace Insert IMPORTANT MESSAGE SAVE THESE INSTRUCTIONS The Regency ® Gas Fireplace must be installed in accordance with these instructions. Carefully read all the instructions in this manual fi rst. Consult the "authority having jurisdiction" to determine the need fo...
Page 8 - CLEARANCES TO COMBUSTIBLES
8 Regency ® E21-2 Gas Fireplace Insert CLEARANCES TO COMBUSTIBLES aaa aaa aaa aaa aaa aaa aaa aaa aaa aaa aaa aaa aaa aaa aaa aaa aaa aaa aaa aaaaa aaaaa aaaaa aaaaa aaaaa aaaaa aaaaa aaaaa aaaaa aaaaa aaaaa aaaaa INSTALLATION The minimum clearance from the side of the appliance to a combustible sid...
Page 9 - HIGH ELEVATION; System Data; GAS CONNECTION
9 Regency ® E21-2 Gas Fireplace Insert HIGH ELEVATION This unit is approved in Canada for altitude 0 to 4500 ft. (CAN/CGA 2.17-M91) with the orifi ce supplied. System Data For altitude: Natural Gas 0-2000 ft. Propane: 0-4500 ft. Burner Inlet Orifi ce Sizes: Natural Gas Propane Burner #43 #54 Max. Inpu...
Page 10 - WIRING DIAGRAMS; WARNING: Electrical Grounding; Grounding; For; NATURAL GAS; Units and Units; NOT; Equipped with DC Spark Boxes
10 Regency ® E21-2 Gas Fireplace Insert WIRING DIAGRAMS INSTALLATION CAUTION: Label all wires prior to disconnection when servicing c o n t r o l s . W i r i n g e r r o r s c a n cause improper and dangerous operation. WARNING: Electrical Grounding Instructions This appliance is equipped with a thr...
Page 11 - FLUE CONNECTOR INSTALLATION; PROPANE; Units and Units Equipped with DC Spark Boxes*
11 Regency ® E21-2 Gas Fireplace Insert Note: Do not operate unit if fl ue connector is not fastened in original position. FLUE CONNECTOR INSTALLATION 1) Remove the screw holding the fl ue connector plate to the appliance. 2) Slide the plate out and attach to the fl ue liner inside the fi replace to the...
Page 15 - FLUSH GLASS; The use of substitute glass will
15 Regency ® E21-2 Gas Fireplace Insert Diagram 4 Diagram 5 6) Connect the ON/OFF switch wires by taking the black and red wires with the female ends and connecting them to the ON/OFF switch. FLUSH GLASS 1) Install the bottom glass trim onto the glass support. 2) Slide the glass into the bottom glas...
Page 16 - BAY LOUVERS; OPTIONAL BAY FRONT; IMPORTANT; FLUSH LOUVERS
16 Regency ® E21-2 Gas Fireplace Insert BAY LOUVERS 1) Install top louver by sliding the two bracket clips into the brackets located on top of the bay door. See below. The fi tted louver leaves a small gap between faceplate bottom and louver top. Diagram 1 NOTE: The top and bottom trim pieces are dif...
Page 17 - THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER
17 Regency ® E21-2 Gas Fireplace Insert Conversion Kit# 534-969 from NG to LP THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !! Each Kit contains one LPG Conversion Kit and one DCSparker Kit. LPG Conversion Kit Contains:Qty. Part # Description 1 904-163 ...
Page 18 - Installation of the DC Sparker:
18 Regency ® E21-2 Gas Fireplace Insert 17) Verify that if the conversion is from NG to LPG, the screw must be re-assembled with the red o-ring visible (Fig. 5). 18) Re-assemble the black protection cap (Fig. 6). WARNING! Also check that the pilot and main burner injectors are appropriate for the ga...
Page 19 - These instructions must
19 Regency ® E21-2 Gas Fireplace Insert Installer Notice: These instructions must be left with the appliance. 39) Check for gas leaks. 40) Check inlet and outlet pressures. 41) Check operation of fl ame control. 42) Check for proper fl ame appearance and glow on logs. 29) Locate the ground lug at th...
Page 20 - FULL SCREEN DOORS
20 Regency ® E21-2 Gas Fireplace Insert FULL SCREEN DOORS 1) Hold the full screen door up against the unit in order to make the following wire connections. Pull the ON/OFF connector wires thru the box and connect them to the switch. Connect the fan switch wires with the wire connectors from the fan ...
Page 22 - Thermostat Wire Table; WALL SWITCH; CAUTION; REMOTE CONTROL; CAUTION; WALL THERMOSTAT
22 Regency ® E21-2 Gas Fireplace Insert Thermostat Wire Table CAUTION Do not wire millivolt wall thermostat wires to 120V wire. WALL SWITCH 1) Run the wire through the right or left side inlet opening. Be careful not to damage the wire. Note: We recommend a maximum of 15' of wire but if you wish to ...
Page 23 - OPERATING INSTRUCTIONS
23 Regency ® E21-2 Gas Fireplace Insert FINAL CHECK Before leaving this unit with the customer, the installer must ensure that the appliance is fi ring correctly. This includes: 1) Clocking the appliance to ensure the correct fi ring rate (rate noted on label) at 15 minutes. 2) If required, adjusting ...
Page 24 - COPY OF LIGHTING PLATE INSTRUCTIONS
24 Regency ® E21-2 Gas Fireplace Insert OPERATING INSTRUCTIONS COPY OF LIGHTING PLATE INSTRUCTIONS LIGHTING INSTRUCTIONS TO TURN OFF GAS APPLIANCE Gas Inlet
Page 25 - MAINTENANCE
25 Regency ® E21-2 Gas Fireplace Insert MAINTENANCE INSTRUCTIONS 1) Always turn the gas valve to off before cleaning. For relighting, refer to lighting instructions. Keep the burner and control c o m p a r t m e n t c l e a n b y b r u s h i n g a n d vacuuming at least once a year. When cleaning th...
Page 26 - REMOVING THE FAN; DOOR GLASS; Bay Glass Removal; Flush Glass Replacement
26 Regency ® E21-2 Gas Fireplace Insert REMOVING VALVE ASSEMBLY 1) Disconnect the power. 2) Shut off the gas. 3) Remove top and bottom louvers. 4) Remove top and bottom trim. 5) Remove glass. 6) Remove log set & embers, and brick panels. 7) Disconnect the gas line. 8) Remove wires from valve (to...
Page 27 - PARTS LIST; MAIN ASSEMBLY
27 Regency ® E21-2 Gas Fireplace Insert 3 1 10 12 21 33 35 34 36 36 B R IC K PA N E L S E T 23 2 7 4 5 8 38 38 39 13 17 26 25 FR O N TS P LE A S E R E FE R S E PA R ATE ILLU S TR ATIO N 49 PARTS LIST MAIN ASSEMBLY Part # Description Part # Description 530-518/P Fan Assembly 1) 910-331/P Fan Motor (1...
Page 28 - BURNER ASSEMBLY & LOG SET
28 Regency ® E21-2 Gas Fireplace Insert 53 61 59 58 57 56 52 69 62 BURNER ASSEMBLY & LOG SET Part # Description 533-574/P Valve Assembly- NG 533-576/P Valve Assembly - LPG 52) 910-468 Valve SIT - NG/LPG 53) 910-190 Piezo Ignitor & Nut 56) 910-076 Pilot Assembly - SIT - 3 fl ame -NG 910-077 Pi...
Page 29 - BAY & FLUSH FRONT ASSEMBLY
29 Regency ® E21-2 Gas Fireplace Insert PARTS LIST BAY & FLUSH FRONT ASSEMBLY Part # Description Part # Description Bay Door 530-950 Complete Bay Front c/w Black Trim 106) 940-312/P Side Glass 107) 936-243 Gasket - Adhesive Backed 7/8" 108) 940-313/P Center Glass 110) 402-905 Bay Brick Panel...
Page 30 - FACEPLATE ASSEMBLY
30 Regency ® E21-2 Gas Fireplace Insert FACEPLATE ASSEMBLY Part # Description 91) 910-330 Fan Speed Control (120 V) 92) 904-569 Fan Speed Control Knob 93) 910-246 Burner Switch ON/OFF (2 way) 400-950 Hearth Trim 1" Standard 320-940 Hearth Trim 1" Oversize 400-926 Hearth Trim 2" Standard ...
Page 31 - WARRANTY
31 Regency ® E21-2 Gas Fireplace Insert WARRANTY Regency ® Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each unit thoroughly before it leaves our facility. FPI Fireplace Products International Ltd. is ple...
Page 32 - Installer: Please complete the following information; Printed in Canada
32 Regency ® E21-2 Gas Fireplace Insert Installer: Please complete the following information Dealer Name & Address: ______________________________________________ ___________________________________________________________________ Installer: ______________________________________________________...