Page 2 - replace; MANUFACTURED MOBILE HOME REQUIREMENTS; INFORMATION FOR MOBILE/MANUFACTURED HOMES AFTER FIRST SALE; This Regency
2 Regency Bellavista™ B36X Gas Fireplace To the New Owner: Congratulations! You are the owner of a state-of-the-art Gas Fireplace by REGENCY ® . The Bellavista™ B36X has been designed to provide you with all the warmth and charm of a wood fi replace at the fl ick of a switch. The Bellavista™ B36X ha...
Page 3 - TABLE OF CONTENTS; Regency
3 Regency Bellavista™ B36X Gas Fireplace TABLE OF CONTENTS SAFETY LABEL Copy of Safety Decal ..................................................... 4 REQUIREMENTS MA Code - CO Detector................................................. 5 DIMENSIONS Unit Dimensions .........................................
Page 4 - SAFETY LABEL; COPY
4 Regency Bellavista™ B36X Gas Fireplace SAFETY LABEL This is a copy of the label that accompanies each Bellavista™ B36X Direct Vent Gas Fireplace. We have printed a copy of the contents here for your review. NOTE: Regency ® units are constantly being improved. Check the label on the unit and if the...
Page 5 - REQUIREMENTS; MA Code - CO Detector
5 Regency Bellavista™ B36X Gas Fireplace REQUIREMENTS 5.08: Modifications to NFPA-54, Chapter 10 (2) Revise 10.8.3 by adding the following additional requirements: (a) For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in pa...
Page 6 - DIMENSIONS; UNIT DIMENSIONS
6 Regency Bellavista™ B36X Gas Fireplace DIMENSIONS UNIT DIMENSIONS 37-1/2” (953mm) 21”(533mm) 33” (838mm) 36” (914mm) 35-1/4” (895mm) 30-3/8” (762mm) 1”(25.4mm) 39-1/16” (992mm) 35-1/4” (895mm) 26-1/2” (673mm) 20-1/4” (514mm) 17-5/16” (440mm) 33-1/16” (840mm) 19-5/16” (490mm)
Page 7 - INSTALLATION
7 Regency Bellavista™ B36X Gas Fireplace 11) Under no circumstances should this appliance be modi fi ed. Parts that have to be removed for servicing should be replaced prior to operating this appliance. 12) Installation and any repairs to this appliance should be done by a quali fi ed service person...
Page 9 - CLEARANCES; B36X Clearance Requirements; Dimension
9 Regency Bellavista™ B36X Gas Fireplace INSTALLATION Caution Requirements The top, back and sides of the fi replace are de fi ned by standoffs. The metal ends of the standoff may NOT be recessed into combustible construction. WARNING Fire hazard is an extreme risk if these clearances (air space) to...
Page 10 - MANTEL CLEARANCES; Combustible; Top Header; Side View; MANTEL LEG CLEARANCES; (Measured from side of; Allowable mantel leg
10 Regency Bellavista™ B36X Gas Fireplace INSTALLATION MANTEL CLEARANCES Note: Ensure the paint that is used on the mantel and the facing is "heat resistant" or the paint may discolour. Combustible Mantel Clearances 2 0 12 6 4 8 10 0 Top of Fireplace Opening 12” 1" 7” A B C Top Header 14...
Page 11 - FRAMING; U V
11 Regency Bellavista™ B36X Gas Fireplace INSTALLATION FRAMING M N O Q P R U V T Opening for gas connection 11" (279mm) dia. Hole through wall Vent. Top Header Drywall (or other facing) Combustible Facing S S Framing Dimensions Description B36X M Framing Width 36 - 1/4"(921mm) N Framing Heig...
Page 12 - FINISHING; IMPORTANT FINISHING DETAIL NOTE:
12 Regency Bellavista™ B36X Gas Fireplace INSTALLATION FINISHING Diagram 2 Diagram 1 IMPORTANT FINISHING DETAIL NOTE: Before placing unit into fi nal position - it is important to know the total thickness / height of fi nished hearth (tile, carpet, etc.) The base of the fi replace should be level or...
Page 13 - BEFORE YOU START; TOP STANDOFF ASSEMBLY; TOP FACING SUPPORT; Screw Facing; SIDE NAILING STRIPS; UNIT ASSEMBLY PRIOR TO INSTALLATION
13 Regency Bellavista™ B36X Gas Fireplace BEFORE YOU START The Top Facing Support, the Side Nailing Strips, the 2 Top Standoffs and the Flue Collar must be correctly positioned and attached before the fi replace is moved into position. TOP STANDOFF ASSEMBLY The top standoffs are shipped in a fl at p...
Page 14 - TOP FLUE COLLAR INSTALLATION
14 Regency Bellavista™ B36X Gas Fireplace INSTALLATION TOP FLUE COLLAR INSTALLATION Note: This conversion must be done prior to the unit being placed in position. The unit comes equipped as a rear vent unit. These instructions are to be used, only if the unit is going to be top vented. Top Collar As...
Page 15 - VENTING
15 Regency Bellavista™ B36X Gas Fireplace INSTALLATION 6) From the outside top of the fi rebox, remove the intake collar plate by removing the 4 - 1/4" x 1/2 " screws. See Diagram 6. 5) From the outside rear of the fi rebox, remove the intake collar assembly. Remove the 4 - 1/4" x 1/2...
Page 16 - EXTERIOR VENT TERMINATION REQUIREMENTS; Minimum Clearance Requirements
16 Regency Bellavista™ B36X Gas Fireplace EXTERIOR VENT TERMINATION REQUIREMENTS INSTALLATION Minimum Clearance Requirements Canada 1 USA 2 A Clearance above grade, veranda, porch, deck, or balcony 12"(30cm) 12"(30cm) B Clearance to window or door that may be opened 12"(30cm) 9" (23c...
Page 17 - APPROVED VENTING CONFIGURATIONS
17 Regency Bellavista™ B36X Gas Fireplace INSTALLATION APPROVED VENTING CONFIGURATIONS HORIZONTAL & VERTICAL TERMINATIONS
Page 19 - RIGID PIPE CROSS REFERENCE CHART
19 Regency Bellavista™ B36X Gas Fireplace INSTALLATION RIGID PIPE CROSS REFERENCE CHART 4" X 6-5/8" (MUST USE VENT REDUCER # 946-606 AND RIGID PIPE ADAPTOR #770-994) Components from different Manufacturers may not be mixed. Not all Rigid Pipe components are available directly from FPI.
Page 23 - HORIZONTAL TERMINATIONS
23 Regency Bellavista™ B36X Gas Fireplace INSTALLATION HORIZONTAL TERMINATIONS REGENCY ® DIRECT VENT FLEX SYSTEM (5" X 8") These venting systems, in combination with the B36X Direct Vent Gas Fireplace, has been tested and listed as a direct vent heater system by Warnock Hersey. The location ...
Page 24 - ertical
24 Regency Bellavista™ B36X Gas Fireplace INSTALLATION Rigid Pipe Adaptor Pipe Length 90 Elbow o Horizontal Termination Cap Wall Thimble Vinyl Siding Standoff (Optional) Rigid Pipe Adaptor Pipe Length Horizontal Termination Cap Wall Thimble Vinyl Siding Standoff (Optional) Horizontal Termination A T...
Page 25 - RIGID PIPE VENTING SYSTEMS; Horizontal or Vertical Terminations
25 Regency Bellavista™ B36X Gas Fireplace Pipe Length Vertical Termination Cap Storm Collar Flashing Ceiling Firestop Rigid Pipe Adaptor Pipe Length Pipe Length 90 Elbow o Astrocap (946-523/P) Wall Thimble Vinyl Siding Standoff (Optional) Reducer (4” x 6-5/8” venting) 43” (1092 mm) RIGID PIPE VENTIN...
Page 26 - HORIZONTAL 5” X 8” RIGID REAR VENT KIT
26 Regency Bellavista™ B36X Gas Fireplace INSTALLATION Rigid Pipe Adaptor Pipe Length Astrocap XL Wall Thimble Vinyl Siding Standoff (Optional) 45 elbow 0 Designed for a minimum vent confi guration when using a rear vent application with a horizontal termination in a corner installation. Kit 946-612...
Page 27 - VENTING ARRANGEMENTS; ALLOWABLE VERTICAL TERMINATIONS
27 Regency Bellavista™ B36X Gas Fireplace VENTING ARRANGEMENTS ALLOWABLE VERTICAL TERMINATIONS (MUST USE VENT REDUCER # 946-606 & RIGID PIPE ADAPTOR #770-994) 4" X 6 - 5/8" PIPE VENTING ARRANGEMENTS The shaded area in the diagram shows all allowable combinations of straight vertical and ...
Page 28 - ELBOWS; VENTING ARRANGEMENTS HORIZONTAL TERMINATION; Option V
28 Regency Bellavista™ B36X Gas Fireplace INSTALLATION HORIZONTAL VENTING WITH TWO (2) 90 O ELBOWS (RIGID PIPE 4" X 6 - 5/8") 16 2 2 0 0 12 12 6 6 18 4 49"(1245mm)MinimumHeightRequirement 4 14 8 8 10 10 14 16 18 20 V ertical Height (Feet) Horizontal (Feet) Restrictor 1” Open Restrictor 2...
Page 29 - Option V
29 Regency Bellavista™ B36X Gas Fireplace HORIZONTAL VENTING WITH THREE (3) 90 O ELBOWS (RIGID PIPE 4" X 6 - 5/8") V1 H1 H V Lengths do not include elbow indicated.Must use reducer # 946-606 and rigid pipe adaptor #770-994. Option V H V + V1 H + H1 A) 0' Min. 1' Max. 1' Min. 2' Max. B) 1' Mi...
Page 30 - VERTICAL TERMINATION
30 Regency Bellavista™ B36X Gas Fireplace INSTALLATION VERTICAL TERMINATION WITH CO-LINEAR FLEX SYSTEM THE APPLIANCE MUST NOT BE CONNECTED TO A CHIMNEY FLUE SERVING A SEPARATE SOLID FUEL BURNING APPLIANCE. This appliance is designed to be attached to two 3" (76mm) co-linear aluminium fl ex runni...
Page 31 - VENTING ARRANGEMENT - VERTICAL TERMINATIONS; FOR BOTH RESIDENTIAL & MANUFACTURED HOMES
31 Regency Bellavista™ B36X Gas Fireplace VENTING ARRANGEMENT - VERTICAL TERMINATIONS CO-LINEAR FLEX SYSTEM INTO MASONRY FIREPLACES FOR BOTH RESIDENTIAL & MANUFACTURED HOMES The shaded area in the diagrams show the allowable vertical terminations. INSTALLATION 30' Max. 8' Min. 51-1/4” 30 Horizon...
Page 32 - UNIT INSTALLATION
32 Regency Bellavista™ B36X Gas Fireplace Diagram 7 Diagram 5 7) E n s u r e t h a t t h e p i p e c l e a r a n c e s t o combustible materials are maintained (Diagram 5). Install the termination cap. Note: If installing termination on a vinyl siding covered wall, a vinyl siding standoff or furring...
Page 33 - Do not locate termination; HORIZONTAL TERMINATION; ASTROCAPXL
33 Regency Bellavista™ B36X Gas Fireplace on top and bottom. Fasten the other thimble half to the inside wall. The thimble halves slip inside each other and can be adjusted for 2 x 4 or 2 x 6 walls. 5) Slip the assembled liner and termination assembly through the thimble making sure the termination ...
Page 34 - MUST USE REDUCER
34 Regency Bellavista™ B36X Gas Fireplace GAS LINE INSTALLATION The gas line is brought through the right side of the appliance. The gas valve is situated on the right hand side of the unit and the gas inlet is on the right hand side of the valve. The gas line connection may be made of rigid pipe, c...
Page 35 - GAS PIPE PRESSURE; HIGH ELEVATION; PILOT ADJUSTMENT; B36X -NG System Data
35 Regency Bellavista™ B36X Gas Fireplace INSTALLATION GAS PIPE PRESSURE TESTING The appliance must be isolated from the gas supply piping system by closing its individual manual shut-off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 ps...
Page 36 - WIRING DIAGRAM; For; NATURAL GAS; Units and Units; NOT; Equipped with DC Spark Boxes
36 Regency Bellavista™ B36X Gas Fireplace WIRING DIAGRAM AERATION ADJUSTMENT The burner aeration is factory set but may need adjusting due to either the local gas supply or altitude. Open the air shutter for a blue fl ame or close for a more yellow fl ame. Minimum Air Shutter Opening: NG 1/16" L...
Page 37 - PROPANE; Units and Units Equipped with DC Spark Boxes*; WIRING DIAGRAM FOR GTMF REMOTE
37 Regency Bellavista™ B36X Gas Fireplace INSTALLATION Lockwasher Fan ground wire Nut #8 Ground Lug (for mobile home) Star washer To Thermocouple IN Pilot Assembly H I LO OFF ON P IL O T Gas Pilot Thermopile Thermocouple Electrode Remote Transmitter (Optional) ON OFF Regency Remote Receiver or Therm...
Page 38 - VENT RESTRICTOR, BAFFLE & HEAT DEFLECTOR INSTALLATION
38 Regency Bellavista™ B36X Gas Fireplace INSTALLATION VENT RESTRICTOR, BAFFLE & HEAT DEFLECTOR INSTALLATION NOTE: THE VENT RESTRICTOR & BAFFLE MUST BE INSTALLED PRIOR TO OPTIONAL BRICK PANEL INSTALLATION. Note: If installing brick panels, see brick panel instructions before proceeding to ne...
Page 39 - for B36X using SIT 820 NOVA Gas Valve; THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER
39 Regency Bellavista™ B36X Gas Fireplace INSTALLATION CONVERSION KIT# 556-969 FROM NG TO LP for B36X using SIT 820 NOVA Gas Valve THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !! 1) Shut off the gas supply. 2) Remove the louvers (and Arch screen doors ...
Page 40 - Also check that the pilot and main; Cap
40 Regency Bellavista™ B36X Gas Fireplace INSTALLATION 18) Verify that if the conversion is from NG to LPG, the screw must be re-assembled with the red o-ring visible (Fig. 5). 19) Re-assemble the black protection cap (Fig. 6). LPG Configuration Red o-ring visible Fig.5 20) Reverse steps 8 - 1. 21) ...
Page 41 - DC Sparker Battery Replacement; DC SPARKER INSTALLATION
41 Regency Bellavista™ B36X Gas Fireplace INSTALLATION DC Sparker Battery Replacement 23) Locate the Piezo Ignitor situated at the right side of the valve assembly. 24) Remove the Piezo Ignitor wire from the back of the Piezo Ignitor. 25) Connect the ignitor wire from the Piezo to the DC sparker. 1)...
Page 42 - BRICK PANEL INSTALLATION
42 Regency Bellavista™ B36X Gas Fireplace INSTALLATION Dangerous operating conditions may occur if the panels are broken. Handle with care. DO NOT FORCE INTO POSITION. 1) Unwrap the Brick Panels from the protective wrapping. 2) Ensure that the logs are not in the unit. 3) Remove the heat defl ector ...
Page 43 - OPTIONAL STAINLESS STEEL / BLACK ENAMEL; STAINLESS STEEL PANEL INSTALLATION; Stainless Steel Panels
43 Regency Bellavista™ B36X Gas Fireplace INSTALLATION OPTIONAL STAINLESS STEEL / BLACK ENAMEL PANEL INSTALLATION 1) Remove the heat defl ector by removing the 2 screws securing the heat defl ector to the top of the fi rebox (see Diagram 2). 2) Loosen the 2 baffl e screws - position the top panel in...
Page 44 - BLACK ENAMEL PANEL INSTALLATION
44 Regency Bellavista™ B36X Gas Fireplace INSTALLATION 5) Repeat step 4 for left side panel. 5) Repeat step 4 for left side panel. 6) Reverse step 1. 6) Reverse step 1. Final Installation Final Installation 4) Remove 1 screw (see inset A), position right side panel in fi rebox - position panel clip ...
Page 45 - LOG SET INSTALLATION
45 Regency Bellavista™ B36X Gas Fireplace INSTALLATION LOG SET INSTALLATION Installation of Brick Panels must be completed before installing the log set. Read the instructions below carefully and refer to the images. If the logs are broken do not use the unit until they are replaced. Broken logs can...
Page 48 - WALL SWITCH; Optional; CAUTION; Thermostat Wire Table; Optional; CAUTION; Wire Size
48 Regency Bellavista™ B36X Gas Fireplace WALL SWITCH (INCLUDED) 1) Run the supplied 10' of wire through the right or left side gas inlet opening. Be careful not to damage wire. Note: We recommend a maximum of 10' of wire but if you wish to go with a longer run, use the Thermostat Wire Table. 2) Con...
Page 50 - FAN INSTALLATION; TO REMOVE THE FAN
50 Regency Bellavista™ B36X Gas Fireplace FAN INSTALLATION INSTALLATION Important: 120 Volt AC power is needed for the fan switch and blower. The receptacle box will be installed on the left hand side of the unit and will need to be wired by a qualifi ed electrician prior to fan assembly being insta...
Page 51 - FLUSH GLASS DOOR INSTALLATION
51 Regency Bellavista™ B36X Gas Fireplace INSTALLATION FLUSH GLASS DOOR INSTALLATION 1) Line up slots on fl ush glass door with tabs in fi rebox. Hook slots on to tabs and lower door slowly (See Diagram 1). 2) Lower the fl ush door, then hook the 2 adjustable tension latches - close the latches to s...
Page 52 - Install the Finishing Trim prior to installing the Flush Louvers.; Secure with 2 screws per side.; OPTIONAL FINISHING TRIM INSTALLATION
52 Regency Bellavista™ B36X Gas Fireplace INSTALLATION Finishing Trim Top Finishing Trim Side NOTE: Install the Finishing Trim prior to installing the Flush Louvers. 1) Install the Finishing Trim sides as shown in the diagram; line up the holes in the side trim with the holes in the fi rebox side. 2...
Page 53 - FULL SCREEN ARCH DOOR AND FRAME INSTALLATION
53 Regency Bellavista™ B36X Gas Fireplace INSTALLATION FULL SCREEN ARCH DOOR AND FRAME INSTALLATION Diagram 1 Diagram 2 Diagram 4 Diagram 3a Diagram 3b Diagram 5 Final Screen Install 1) Remove glass door (refer to glass door removal in the manual). 2) Install 4 Phillips screws (supplied with packagi...
Page 54 - OPERATING INSTRUCTIONS; IMPORTANT; HOT
54 Regency Bellavista™ B36X Gas Fireplace OPERATING INSTRUCTIONS 1) Read and understand these instructions before operating this appliance. 2) Check to see that all wiring is correct and enclosed to prevent possible shock. 3) Check to ensure there are no gas leaks. 4) Make sure the glass in the glas...
Page 55 - COPY OF LIGHTING PLATE INSTRUCTIONS
55 Regency Bellavista™ B36X Gas Fireplace OPERATING INSTRUCTIONS COPY OF LIGHTING PLATE INSTRUCTIONS OFF a
Page 56 - MAINTENANCE; GLASS REPLACEMENT; General Vent Maintenance
56 Regency Bellavista™ B36X Gas Fireplace MAINTENANCE 2) Remove the Cap, and shine a fl ashlight down the Vent. Remove any bird nests, or other foreign material. 3) C h e c k f o r e v i d e n c e s o f e x c e s s i v e condensation, such as water droplets forming in the inner liner, and subsequent...
Page 57 - REMOVING VALVE; INSTALLING VALVE
57 Regency Bellavista™ B36X Gas Fireplace MAINTENANCE REMOVING VALVE 10) Remove the 8 Phillips head screws securing the valve tray assembly in place (Diagram 6) and then lift the entire assembly out (Diagram 7). 1) Shut off the gas supply. 2) Remove the louvers 3) Open the fl ush door and remove the...
Page 58 - PARTS LIST; MAIN ASSEMBLY
58 Regency Bellavista™ B36X Gas Fireplace PARTS LIST MAIN ASSEMBLY Part # Description 1) 556-524 Flue Collar Outer Assembly2) 556-085 Flue Collar Gasket 3) 556-097 Exhaust Gasket 4) 556-513 Flue Collar Inner Assembly 5) 556-088F Top Relief Plate6) 556-094 Relief Gasket - Door Top 7) 576-901 Brick Pa...
Page 60 - BURNER ASSEMBLY
60 Regency Bellavista™ B36X Gas Fireplace BURNER ASSEMBLY 1 2 4 3 5 6 7 9 10 PARTS LIST Part # Description 1) 556-077 Rear Log Tray2) 904-532 Insert 3) 556-525 B36X Burner Assembly 4) 556-057 B36X Grate Assembly 5) 904-655 Ori fi ce # 45 NG 904-575 Ori fi ce # 55 LP 6) 910-568 Valve NG/LP SIT High/L...
Page 61 - NOTES
Page 63 - WARRANTY
63 Regency Bellavista™ B36X Gas Fireplace WARRANTY Regency ® Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each unit thoroughly before it leaves our facility. FPI Fireplace Products International Ltd. is p...
Page 64 - Installer: Please complete the following information; Printed in Canada; Register your Regency
64 Regency Bellavista™ B36X Gas Fireplace Installer: Please complete the following information Dealer Name & Address: ______________________________________________ ___________________________________________________________________ Installer: ____________________________________________________...