Raypak H7 504-2004 - Manual

Raypak H7 504-2004

Raypak H7 504-2004 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
Page: / 2
Loading the manual

Catalog No.: 2000.364A

Effective: 8-15-07

Replaces: 6-15-07

Job:

Engineer:

Contractor:

Prepared By:

Date:

Model:

Indoor/Outdoor:

84% Thermal Efficiency at Full Rate

100% Factory Fire Tested

Maximum Outlet Water Temperature: 220°F

Minimum Acceptable Inlet Water Temperature: 120°F

Full Safety Diagnostics with History

Footprint: Less Than 5-1/2 ft

2

Limited Twenty-Year Thermal Shock Warranty

Limited Ten-Year Heat Exchanger Warranty

Electronic Modulation, Constant Ratio 1.4:1 Turndown

TempTracker Mod Controller with LCD Display

Status Display Lights

Heat Exchanger

ƒ

Bronze Headers

ƒ

ASME H Stamped

160 PSIG Working Pressure

ƒ

National Board Approved

ƒ

Fin Tubing

Copper – Standard
Cupro Nickel – Option A-3

ƒ

ASME Powder-Coated Tube Sheet

ƒ

Silicone High Temp O-Rings

ƒ

ASME Pressure Relief Valve

60 PSIG – Standard
PSIG – Optional

ƒ

Temperature and Pressure Gauge,

Shipped Loose

ƒ

Stainless Steel Evaporator Plate

Control

ƒ

120V, 60Hz, 1Ø, Power Supply

ƒ

120/24V 60Hz Transformer

ƒ

Ignition Module

3-Try – Standard
Single-Try – Option C-6

ƒ

Hot Surface Ignition (HSI)

ƒ

Remote Flame Sensor

ƒ

High Limit, Manual Reset, Fixed,

240ºF

ƒ

On/Off Power Switch

ƒ

Flow Switch

ƒ

Blocked Vent Pressure Switch

ƒ

Combustion Air Proving Switch

ƒ

Pump Switch

ƒ

Pump Time Delay

ƒ

Diagnostics Panel

ƒ

Modulating Temperature Control

ƒ

Water Temperature Sensors (3)

Burner

ƒ

Ultra-Low NOx: Less than 20 PPM

Gas Train

ƒ

Fuel

Natural Gas
Propane

ƒ

Zero Governor Regulator

ƒ

Dual-Seat Combination Valve

ƒ

Electronic Modulating Firing Mode

Construction

ƒ

Indoor/Outdoor Construction

ƒ

Front Controls Enclosed

ƒ

PolyTuf Powder Coat Finish

ƒ

Rear Connections (Water, Electrical,

Gas, Vent, Combustion Air)

ƒ

Design Certified ANSI Z21.13/

CSA 4.9

Venting

ƒ

Vent Termination Cap

Outdoor - Option D-11
Indoor, Horizontal – Option D-15
Indoor, Vertical (by others)

ƒ

Combustion Air

In-Line Filter Kit – Option D-17
Air Intake Elbow – Option D-16

ƒ

Extractor – Optional

By others
Not required


Temperature Controllers

B-36 Temp-Tracker Mod+ Digital

Controller, Up to 4 Boilers,
OA Reset

B-37 Temp-Tracker Mod+ Digital

Controller, Up to 10 Boilers,
OA Reset

B-38 Temp-Tracker Mod+ Digital

Controller, Up to 16 Boilers,
OA Reset

Y-241 Electronic Sequencer,

Up to 4 Boilers

Y-281 Electronic Sequencer,

Up to 8 Boilers

Options

A-13 Air Vent, Auto, 150 PSI
F-10 Low Water Cut-Off, Remote Probe
I-1

High Limit, Auto Reset, Adj.,
100-240

°

F

I-2

High Limit, Manual Reset, Adj.,
100-240

°

F

P- Pump: HP, 120V, 1

, 60Hz

Water Hardness: GPG

Cast Iron

Bronze

Loose

Mounted

P- Cold Water Start
P- Cold Water Run
S-1

Low Gas Pressure Switch,
Manual Reset

S-2

High Gas Pressure Switch,
Manual Reset

Regulatory Agency Requirements

MVB™ - Type H

Heating/Hot Water Supply Boilers

Models H7 504-2004

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Other Raypak Models

All Raypak Other